Health Test Report

Report No.: AGC00550220602EH02

General Information

ApplicantShenzhen Hairuichuang Technology Co., Ltd.
ManufacturerShenzhen Hairuichuang Technology Co., Ltd.
FactoryShenzhen Hairuichuang Technology Co., Ltd.
AddressRoom 2001, Building A, Weidonglong Business Building, No. 2125, Meilong Avenue, Longhua District, Shenzhen, China
Product Designationsmartwatch
Brand NameBlackview, IOWODO, FeipuQu
Test ModelW10
Series ModelW10Pro, W20, W20Pro, W30, W30Pro, W40, W40Pro, W50, W50Pro, W60, W60Pro, W70, W70Pro, W80, W80Pro, W90, W90Pro, R8Pro
Difference DescriptionAll the same except for the model name.
Date of Receipt of Test ItemSep. 15, 2022
Date of TestSep. 15, 2022 to Oct. 13, 2022
Test ResultPass

Attestation of Global Compliance (Shenzhen) Co., Ltd. conducted testing for compliance with the requirements set forth in the European Standard EN 62479:2010. The results of testing in this report apply only to the product/system which was tested.

Prepared By: Thea Huang (Project Engineer) - Oct. 13, 2022

Reviewed By: Calvin Liu (Reviewer) - Oct. 13, 2022

Approved By: Max Zhang (Authorized Officer) - Oct. 13, 2022

Technical Information

Product Designationsmartwatch
Brand NameBlackview, IOWODO, FeipuQu
Test ModelRH281-V03
Hardware VersionV03
Software VersionV1.0
Operating Frequency2.402 GHz to 2.480GHz
Bluetooth VersionV 5.2
Modulation TypeBR: GFSK_1Mbps ; EDR: π/4-DQPSK_2Mbps, 8DPSK_3Mbps
BLE: [x] GFSK 1Mbps [ ] GFSK 2Mbps
Antenna Type[x] FPC Antenna (Temporary RF connector provided by manufacturer) [ ] Dedicated Antenna
Antenna Gain0.05dBi
Power SupplyDC 3.8V by battery or DC 5V by adapter

Note: For more details, please refer to the user's manual of the EUT.

Test Result

The maximum output power of Bluetooth (BR&EDR) is 4.72dBm (2.96mW), which is less than 20mW. This result is detailed in ETSI EN 300 328 (V2.2.2) Test report (AGC00550220602EE04) and is deemed to comply with the basic restrictions without testing.

The maximum output power of Bluetooth (BLE) is 4.11dBm (2.58mW), which is less than 20mW. This result is detailed in ETSI EN 300 328 (V2.2.2) Test report (AGC00550220602EE11) and is deemed to comply with the basic restrictions without testing.

Conclusion

Remark: EUT meets the basic requirements in the standard.

Conditions of Issuance of Test Reports

All samples and goods are accepted by Attestation of Global Compliance (Shenzhen) Co., Ltd. (the "Company") solely for testing and reporting in accordance with the following terms and conditions. The company provides its services on the basis that such terms and conditions constitute express agreement between the company and any person, firm or company requesting its services (the “Clients").

Any report issued by Company as a result of this application for testing services (the "Report") shall be issued in confidence to the Clients and the Report will be strictly treated as such by the Company. It may not be reproduced either in its entirety or in part and it may not be used for advertising or other unauthorized purposes without the written consent of the Company. The Clients to whom the Report is issued may, however, show or send it, or a certified copy thereof prepared by the Company to its customer, supplier or other persons directly concerned. The Company will not, without the consent of the Clients, enter into any discussion or correspondence with any third party concerning the contents of the Report, unless required by the relevant governmental authorities, laws or court orders.

The Company shall not be called or be liable to be called to give evidence or testimony on the Report in a court of law without its prior written consent, unless required by the relevant governmental authorities, laws or court orders.

In the event of the improper use of the report as determined by the Company, the Company reserves the right to withdraw it, and to adopt any other additional remedies which may be appropriate.

Samples submitted for testing are accepted on the understanding that the Report issued cannot form the basis of, or be the instrument for, any legal action against the Company.

The Company will not be liable for or accept responsibility for any loss or damage however arising from the use of information contained in any of its Reports or in any communication whatsoever about its said tests or investigations.

Clients wishing to use the Report in court proceedings or arbitration shall inform the Company to that effect prior to submitting the sample for testing.

The Company is not responsible for recalling the electronic version of the original report when any revision is made to them. The Client assumes the responsibility to providing the revised version to any interested party who uses them.

Subject to the variable length of retention time for test data and report stored hereinto as otherwise specifically required by individual accreditation authorities, the Company will only keep the supporting test data and information of the test report for a period of six years. The data and information will be disposed of after the aforementioned retention period has elapsed. Under no circumstances shall we provide any data and information which has been disposed of after retention period. Under no circumstances shall we be liable for damage of any kind, including (but not limited to) compensatory damages, lost profits, lost data, or any form of special, incidental, indirect, consequential or punitive damages of any kind, whether based on breach of contract of warranty, tort (including negligence), product liability or otherwise, even if we are informed in advance of the possibility of such damages.

Attestation of Global Compliance (Shenzhen)Co., Ltd

Attestation of Global Compliance (Shenzhen)Std & Tech Co., Ltd

Tel: +86-755 2523 4088 | E-mail: agc@agccert.com | Web: http://www.agccert.com/

Any report having not been signed by authorized approver, or having been altered without authorization, or having not been stamped by the "Dedicated Testing/Inspection Stamp" is deemed to be invalid. Copying or excerpting portion of, or altering the content of the report is not permitted without the written authorization of AGC. The test results presented in the report apply only to the tested sample. Any objections to report issued by AGC should be submitted to AGC within 15days after the issuance of the test report. Further enquiry of validity or verification of the test report should be addressed to AGC by agc01@agccert.com.

PDF preview unavailable. Download the PDF instead.

W10 Health Report BT iText? 5.5.10 ?2000-2015 iText Group NV (AGPL-version); modified using iText? 5.5.10 ?2000-2015 iText Group NV (AGPL-version)

Related Documents

Preview Attestation of Conformity for Blackview, IOWODO, FeipuQu Smartwatches
Official Attestation of Conformity for Shenzhen Hairuichuang Technology Co., Ltd.'s smartwatches, including Blackview, IOWODO, and FeipuQu brands. Details compliance with RED Directive 2014/53/EU for models W10 series through R8Pro, referencing specific EN and ETSI standards.
Preview Shenzhen Hairuichuang Smart Watch ROHS Compliance Certificate
Certificate of Conformity for Shenzhen Hairuichuang smart watches, confirming compliance with EC ROHS Directive 2011/65/EU and (EU) 2015/863, tested against relevant IEC standards.
Preview Blackview Smart Watch RF Test Report AGC14435230901ER03
Official RF test report for Blackview smart watch models, detailing compliance testing by Attestation of Global Compliance (Shenzhen) Co., Ltd. against ETSI EN 300 328 V2.2.2 for 2.4 GHz band operation.
Preview Декларация за съответствие на ЕС - Blackview IOWODO FeiPuQu Baolubao
Декларация за съответствие за продуктите Blackview IOWODO FeiPuQu Baolubao, потвърждаваща съответствието с Директива на ЕС RED 2014/53/ЕС и съответните стандарти за безопасност, здраве, ЕМС и радио.
Preview Blackview IOWODO FeiPuQu Baolubao EU Declaration of Conformity
Official EU Declaration of Conformity for Blackview IOWODO FeiPuQu Baolubao mobile devices, confirming compliance with RED Directive 2014/53/EU and relevant safety, health, EMC, and radio standards.
Preview EU Declaration of Conformity - Blackview IOWODO FeiPuQu Baolubao
Official EU Declaration of Conformity for Blackview IOWODO FeiPuQu Baolubao mobile devices, confirming compliance with RED Directive 2014/53/EU and 2011/65/EU, and listing applicable safety, health, EMC, and radio standards.
Preview EC Declaration of Conformity - Blackview IOWODO FeiPuQu Baolubao
Official EC Declaration of Conformity for Blackview IOWODO FeiPuQu Baolubao devices, confirming compliance with RED 2014/53/EU, 2011/65/EU, and harmonized standards for safety, health, EMC, and radio.
Preview Blackview Smartwatch Health Test Report - Compliance with EN Standards
Official health test report for Blackview, IOWODO, and FeipuQu smartwatches (Model R1 and series R10-R90Pro). Details technical specifications, test results, and compliance with EN 62479:2010 and EN 50663:2017 standards.