RF EXPOSURE Test Report

Report No.: MTi240425022-01E2

Date of issue: 2024-08-05

Applicant: Raycon Inc.

Product: Raycon Open Earbuds

Model(s): RBO725, RBO725 Pro, O25, O25 Pro

FCC ID: 2AZOV-RBO725

Testing Laboratory: Shenzhen Microtest Co., Ltd. (微测检测)

Laboratory Website: http://www.mtitest.cn

Instructions

  1. The report shall not be partially reproduced without the written consent of the laboratory;
  2. The test results of this report are only responsible for the samples submitted;
  3. This report is invalid without the seal and signature of the laboratory;
  4. This report is invalid if transferred, altered or tampered with in any form without authorization;
  5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report.

TEST RESULT CERTIFICATION

ApplicantRaycon Inc.
Address1115 Broadway, Suite 12, New York, NY 10010
ManufacturerRaycon Inc.
Address1115 Broadway, Suite 12, New York, NY 10010
FactoryRaycon Inc.
Address1115 Broadway, Suite 12, New York, NY 10010
Product nameRaycon Open Earbuds
TrademarkRAYCON
Model NameRBO725
Serial ModelRBO725 Pro, O25, O25 Pro
StandardsN/A
Test procedureKDB 447498 D01 v06
Date of Test2024-07-09 to 2024-08-05
Test ResultPass

Testing Engineer: James Qin

Technical Manager: David Lee

Authorized Signatory: Leon Chen

1. Standalone SAR test exclusion considerations

Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied.

These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.

The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander.

To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures.

When no other RF exposure testing or reporting are required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR test exclusion.

When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions.

a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm

The 1-g and 10-g SAR test exclusion thresholds are determined by the following:

Formula: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] √f(GHz) ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where

  • f(GHz) is the RF channel transmit frequency in GHz
  • Power and distance are rounded to the nearest mW and mm before calculation
  • The result is rounded to one decimal place for comparison
  • The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion.

b) For 100 MHz to 6 GHz and test separation distances > 50 mm

The 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B):

  1. {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)√(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz
  2. {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)√10]} mW, for > 1500 MHz and ≤ 6 GHz

c) For frequencies below 100 MHz

The following may be considered for SAR test exclusion (also illustrated in Appendix C):

  1. For test separation distances > 50 mm and < 200 mm, the power threshold at the corresponding test separation distance at 100 MHz in step b) is multiplied by [1 + log(100/f(MHz))]
  2. For test separation distances ≤ 50 mm, the power threshold determined by the equation in c) 1) for 50 mm and 100 MHz is multiplied by ½

SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any SAR test results below 100 MHz to be acceptable.

2. SAR Test Exclusion Thresholds

We use 5mm as separation distance to calculated.

Bluetooth DSS:

Transmit Frequency (GHz)ModeMeasured Power (dBm)Tune-up power (dBm)Max tune-up power(dBm)Result calculation1g SAR test exclusion threshold
2.402GFSK4.954±150.98023
2.441GFSK4.754±150.98813
2.480GFSK5.925±161.25393
2.402π/4 DQPSK4.964±150.98023
2.441π/4 DQPSK4.804±150.98813
2.480π/4 DQPSK5.835±161.25393
2.4028DPSK4.824±150.98023
2.4418DPSK4.714±150.98813
2.4808DPSK5.835±161.25393

Conclusion: For the max result: 1.2539 ≤ 3.0, No SAR is required.

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7543546 Microsoft Word 2016

Related Documents

Preview Raycon Open Earbuds RF Compliance Test Report
Official test report detailing the RF compliance of Raycon Open Earbuds (Models RBO725, RBO725 Pro, O25, O25 Pro) by Shenzhen Microtest Co., Ltd., covering key radio spectrum parameters according to FCC regulations.
Preview Raycon Open Earbuds FCC Authorization Letter
Official Letter of Authorization from Raycon Inc. for their Open Earbuds (Models RBO725, RBO725 Pro, O25, O25 Pro) to LGAI Technological Center S.A. for FCC compliance.
Preview Raycon Product Similarity Declaration for Open Earbuds
Declaration by Raycon Inc. confirming the product similarity between Raycon Open Earbuds models RBO725, RBO725 Pro, O25, and O25 Pro, stating identical electrical and hardware design.
Preview Microtest RBO725 Test Setup Photographs
Detailed photographs of the test setup used by Microtest for evaluating the RBO725 model, covering radiated emissions testing below and above 1GHz.
Preview Raycon RBO725 Open Earbuds: Safety, Specifications, and Compliance Information
This document provides essential safety guidelines, detailed technical specifications, and FCC/IC compliance information for the Raycon RBO725 Open Earbuds, ensuring safe and compliant usage.
Preview Raycon Inc. FCC ID Declaration and Regulatory Compliance
Official declaration from Raycon Inc. concerning the placement of their FCC ID on product documentation and including essential regulatory compliance statements in French and Spanish.
Preview Raycon Inc. FCC Confidentiality Request - 2AZOV-RBO725
Official filing from Raycon Inc. to the FCC requesting confidentiality for technical documents related to FCC ID 2AZOV-RBO725, protecting proprietary information and competitive advantage.
Preview Raycon Inc. US Agent for Service of Process Letter of Attestation - FCC Filing
Official Letter of Attestation designating Raycon Inc. as the US Agent for Service of Process for Raycon Open Earbuds, including FCC ID 2AZOV-RBO725.