Installation Options
The 8870.1 intercom unit can be installed in several ways:
- Surface-wall mount or box installation. Can be fitted to the wall with plugs or a 3-module flush-mounted box (Vimar V71303, V71703).
- Flush-mounted box installation. Can be fitted to the wall with plugs or a 3-module flush-mounted box (Vimar V71303, V71703).
A drilling template for wall installation with plugs is provided.
Mounting the Intercom
To separate the base of the intercom from the cover, insert a flat-head screwdriver into the central slit and turn it until the unit clicks open.
Surface Mounting:
- Fix the top screw (A) in the flush-mounted box (or wall plug), leaving the screw head to protrude by approximately 2 mm.
- Hook the intercom onto the top screw using the appropriate hole in the back, by placing it close to the wall and then pulling downwards.
- Complete mounting by screwing the bottom screw (B) into the appropriate hole.
Wiring Diagram and Components
The document provides a detailed wiring diagram for the electric door opener system with the "C.A. Call" system.
Key Components:
- Power Supply (0931 - 0831): Connects to the mains.
- A - External Audio Entrance Panel (e.g., Patavium series 1200, 1300, 3300, 8000, 8100): The audio unit for the entrance.
- B - Additional Push-button for Lock: An optional button for the electric lock.
- C - Electric Lock 12V~: The electric lock mechanism.
- D - Outdoor Unit (Art. 0930/000.04, 930A): The main outdoor unit.
- L1 - LED Module for Entrance Panel (max. 10 LED modules, or 30 LED modules with Art. M832): LED lighting for the entrance panel.
Conductor Sizing:
Recommended conductor sizes vary based on cable length:
- Up to 50m: Common and lock: 0.5 mm², Others: 0.25 mm²
- Up to 100m: Common and lock: 0.75 mm², Others: 0.5 mm²
- Up to 200m: Common and lock: 1.5 mm², Others: 1 mm²
Intercom Cable Riser: The diagram illustrates the main cable run for the intercom system.
Compatibility and Regulations
- Compatible with additional 12V AC ringtone (0002/818).
- Installation must be carried out by qualified personnel in compliance with current electrical installation regulations in the country of installation.
- The product complies with EMC directives and relevant standards (EN 61000-6-1, EN 61000-6-3).
- Information for users regarding WEEE (Waste Electrical and Electronic Equipment) disposal is provided, emphasizing separate collection and recycling.
- The product may contain traces of lead, as per REACH Regulation (EU) No. 1907/2006.
The full instruction manual is available for download from the Vimar website: www.vimar.com.