User Guide for ENGO CONTROLS models including: EASY230W, EASYBATW, EASY230B, EASYBATB, EASYBATB Wired Thermostat, EASYBATB, Wired Thermostat, Thermostat
EASY-BATB - ENGO
EASY230B - ENGO
File Info : application/pdf, 2 Pages, 714.71KB
DocumentDocumentWired Thermostat, 230V EASY230W / EASYBATW EASY230B / EASYBATB Quick Guide Ver. 3 Release date: I 2024 Soft: v0.6 Producer: Engo Controls S.C. 43-262 Kobielice 4 Rolna St. Poland Distributor: QL CONTROLS Sp z o.o. Sp. k. 43-262 Kobielice 4 Rolna St. Poland www.engocontrols.com Wired, non-programmable thermostat, battery powered (2xAAA) or 230V AC powered. It is used for wired control of heating or cooling devices and systems. It works by maintaining comfortable conditions in the room, in line with the setpoint temperature set by the user. It is connected directly to a heat source or wiring centre. For a better fit, the model is available in two colors. Safe, reliable, easy to use. Product Compliance This product complies with the following EU Directives: 2014/53/EU, 2011/65/EU Technical Informations Power supply Max current 230V or 2xAAA batteries 3 (1) A Temperature range Display temperature accuracy Control algorithm Communication Output control IP protection class 5 35°C 0,1°C TPI or Hysteresis (±0.2°C to ±2°C) Wired COM / NO (voltage-free) IP30 Dimension [mm] 80 x 80 x 22 mm Connection description for EASY230W / EASY230B a) Connection diagram for gas boiler AC 230V L L L EASY230W COM EASY230B NO N N N b) Connection diagram to pump / actuator AC 230V L L EASY230W COM MAX EASY230B 3(1)A NO N N c) Connection diagram to the control box EASY230W EASY230B COM NO NL BOILER CONNECTION* BOILER CONNECTION* Connection description for EASYBATW / EASYBATB AC 230V a) Connection diagram L for gas boiler EASYBATW EASYBATB L 3V COM 2 xAAA NO N N b) Connection diagram to pump / actuator AC 230V L EASYBATW EASYBATB 3V COM MAX 2 xAAA 3(1)A NO N c) Connection diagram to the control box EASYBATW EASYBATB 3V 2 xAAA COM NO N L SL1 1 - 8 Zones ECB08M230 control box N SL1 N L SL1 1 - 8 Zones ECB08M230 control box N SL1 Legend: Boiler - Boiler connection* - Boiler's contacts for ON/OFF thermostat (according to the boiler's instructions) Pump Valve L, N - power supply COM, NO - voltage-free output SL1 - 230V control input in the control box - fuse Description of the LCD display + description of the buttons SWITCH (MODE SELECTION): 12 HEATING OFF 3 COOLING 4 1 2 1. Current / set room temperature 2. Temperature unit 3. Heating mode icon 4. Cooling mode icon Proper thermostat location 1. "MINUS" button 2. "PLUS" button For the thermostat to work properly, it must be installed in a suitable place. Preferably approx. 150 cm above floor level, away from sources of heat or cold. In addition, the thermostat should not be installed behind curtains or other obstacles or in places with high humidity, as this will prevent an accurate measurement of the temperature in the room. It is not recommended to install the thermostat on an outside wall, in a draft or in a place where it will be exposed to direct sunlight. Lock / Unlock the thermostat's keys To lock the keys on the thermostat, press and hold simultaneously - and + buttons for 7 seconds. After the screen appears, release the keys. Thermostat is locked. To unlock the keys on the thermostat, press and hold simultaneously - and + buttons for 7 seconds. After the screen appears, 7 SEC 7 SEC release the keys. Thermostat is unlocked. Installer parameters 0 MAIN SCREEN To enter the service menu, press and hold ,,MINUS"and,,PLUS"buttons for 5 seconds. - 5 SEC 1 CHOOSE A CONTROL ALGORITHM UFH - underfloor heating RAD - radiator heating ELE - electric heating H - hysteresis in the range from 0,4°C to 4,0°C Example: H = 0,4°C = ±0.2°C - 2 MIN. TEMP SETPOINT LIMIT Set the minimum temperature setpoint limit. - 3 MAX. TEMP SETPOINT LIMIT Set the maximum temperature setpoint limit. - 4 TEMPERATURE CALIBRATION Displayed (measured) temperature can be calibrated in steps of 0.1°C (from -3.5°C to + 3.5°C). - 5 BATTERY STATUS* Check the current battery status (%). *only for battery version - 6 OUTPUT CONTROL Select whether the thermostat output has to work as NO = Normally Open or NC = Normally Closed. - 7 RESET Reset thermostat settings to default values. WARNING! After entering the service menu, use - or + buttons to choose parameter. For the parameter selection to be confirmed, wait 3 seconds. The screen will appear with the settings that you can change with - or + buttons. Wait 3 seconds for the selection to be confirmed. + The thermostat will go to the home screen. 5 SEC WAIT 3 SEC + - ... + ... WAIT 3 SEC - + + WAIT 3 SEC - + + WAIT 3 SEC + - + WAIT 3 SEC + WAIT 3 SEC + - + WAIT - + 3 SEC