NIBE PCM 40/PCM 42 Accessory for Free Cooling and Hot Water Production
Features of NIBE™ PCM 40/PCM 42
- Elegant and timeless design
- High flexibility for best indoor climate
- Passive cooling and hot water production simultaneously
- Installer-friendly
- Settings shown on the heat pump's display
- Compatible with heat pumps in the NIBE F1145/F1245 series
NIBE PCM 40/PCM 42 Overview
The NIBE PCM accessory enhances installation flexibility, particularly for users of NIBE F1145/F1245 series heat pumps. It enables advanced applications such as passive free cooling and simultaneous hot water production. This means your system can provide cooling even while it is actively heating domestic hot water.
Control and monitoring are streamlined through the heat pump's integrated control panel, offering user-friendly operation. The accessory's design is intended to complement the aesthetic of NIBE's heat pump equipment.
Technical Specifications
Specification | PCM 40 | PCM 42 |
---|---|---|
Height (excl. pipes) | 515 mm | 635 mm |
Width | 600 mm | 600 mm |
Depth | 370 mm | 370 mm |
Weight | 30 kg | 45 kg |
Connection, hot side | 22 mm | 28 mm |
Connection, cold side | 28 mm | 35 mm |
Output, circulation pump | 40-70 W | 70-160 W |
Cooling output | 2-5 kW | 4-9 kW |
Intended for heat pump at 0/35°C | 5-8 kW | 10-17 kW |
Diagram Descriptions
Dimension Diagrams
PCM 40 Unit Dimensions: The unit measures approximately 515 mm in height (excluding pipes), 600 mm in width, and 370 mm in depth. Connection ports for hot and cold water circuits are located on the unit.
PCM 42 Unit Dimensions: The PCM 42 unit is taller, with a height of approximately 635 mm (excluding pipes), while maintaining the same width of 600 mm and depth of 370 mm. It also features connection ports for the water circuits.
Capacity Diagrams
PCM 40 Cooling Capacity: This graph illustrates the relationship between cooling output (in kW) and water flow rate (in liters per second, l/s). It shows performance curves for two different temperature differences between the supply and return water: 4°C and 3°C. Higher flow rates and smaller temperature differences generally yield higher cooling outputs within the specified ranges.
PCM 42 Cooling Capacity: Similar to the PCM 40, this graph plots cooling output (kW) against flow rate (l/s) for the PCM 42. It also includes performance lines for 4°C and 3°C temperature differences, indicating a greater cooling capacity range compared to the PCM 40.