R17 V2
1 Zone Timeswitch Installation and Operating Guide

Table of contents

Installation Instructions

Factory Default Settings

3

Specifications

3

LCD Display

4

Button Description

5

Wiring Diagram

6

Mounting & Installation

7

Operating Instructions

Quick Introduction to your R17V2 Timeswitch

10

Mode Selection

11

Programming Modes

12

Factory Program Settings

12

Adjust the Program Setting in 5/2 Day Mode

13

Reviewing the Program Settings

14

Boost Function

14

Advance Function

15

Operating Instructions Continued

Menu

16

P01 Setting the Date, Time and the Programming Mode

16

P02 Holiday Mode

17

P03 Frost Protection

18

P04 Zone Title

19

P05 PIN

20

Copy Function

22

Backlight Mode Selection

23

Locking the Keypad

24

Resetting the Timeswitch

24

Master Reset

25

Service Interval

25

1 Zone Timeswitch Installation Instructions

Factory Default Settings

Contacts: Program: Backlight: Keypad Lock: Frost Protection:

Volt Free Contacts 5/2D On Off Off

Operating Mode: Pin Lock: Service Interval: Zone Title:

Specifications

Power Supply: Ambient Temperature: Dimensions: Contact Rating: Program Memory Temperature Sensor: Backlight: IP Rating: Battery:

230VAC 0 ... 50°C 161 x 100 x 31 mm 3(1)A 5 Years NTC 100K White IP20 3VDC Lithium LIR2032 & CR2032

Backplate: Pollution degree:
Software Class:

EPH Controls Ltd.

Auto Off Off ZONE
British System Standard 2 (Resistance to voltage surge 2000V; as per EN60730) Class A
3

LCD Display
[1] Displays current time. [2] Displays current day of the week. [3] Displays zone title. [4] Displays current mode. [5] Displays when keypad is locked. [6] Displays when frost protection is activated. [7] Displays current date.

[2]

[3]

[1] [7]
4

[6] [5]

[4]

R17V2

Button Description

Boost Button Boost
Zone Select Button Select

Menu Button
MENU

Program Advance Plus Minus Button Button Button Button

PROG

ADV

OK Button
OK

Master Reset

EPH Controls Ltd.

5

Wiring Diagram

COM OFF

ON

NL

200-240V~ 50/60Hz

Terminal Connections

Earth

N

Neutral

L

Live

1

COM - Common Connection

2

OFF - N/C Normally Closed Connection

4

ON - N/O Normally Open Connection

6

R17V2

Switching Options
Mains Switching - Link L to 1.
Low Voltage Switching - Remove the external controls link
from the boiler PCB. - Connect 1 and 4 to these terminals.

Mounting & Installation

161

31

100

EPH Controls Ltd.

7

Mounting & Installation continued
Caution!
 Installation and connection should only be carried out by a qualified person.  Only qualified electricians or authorised service staff are permitted to open the timeswitch.  If the timeswitch is used in a way not specified by the manufacturer, its safety may be impaired.  Prior to setting the timeswitch, it is necessary to complete all required settings described in this section.  Before commencing installation, the timeswitch must be first disconnected from the mains.
This timeswitch can be surface mounted or mounted to a recessed conduit box.
1) Remove the timeswitch from its packaging. 2) Choose a mounting location for the timeswitch:
- Mount the timeswitch 1.5 metres above the floor level. - Prevent direct exposure to sunlight or other heating / cooling sources. 3) Use a philips screwdriver to loosen the screws of the backplate on the bottom of the timeswitch. The timeswitch is lifted upwards from the bottom and removed from the backplate.
(See Diagram 3 on Page 7)
4) Screw the backplate onto a recessed conduit box or directly to the surface. 5) Wire the backplate as per the wiring diagram on page 6. 6) Sit the timeswitch onto the backplate making sure the timeswitch pins and the backplate
contacts are making a sound connection, push the timeswitch flush to the surface and tighten the screws of the backplate from the bottom. (See Diagram 6 on Page 7)

8

R17V2

1 Zone Timeswitch Operating Instructions

Quick introduction to your R17V2 Timeswitch:
The R17V2 timeswitch has up to three daily heating programs called P1, P2 and P3. See Page 13 for instructions on how to adjust the program settings.
Within these sections you can see what mode the timeswitch is currently in.
When in the AUTO mode, it will show when the timeswitch is next programmed to be switched ON or OFF.
For `Mode Selection' please see page 11 for further explanation.
When the timeswitch is ON, you will see the red LED light up. This indicates that power is being sent from the timeswitch.

10

R17V2

Mode Selection

AUTO

There are four modes available for selection.

AUTO The timeswitch operates up to three `ON/OFF' periods per day (P1,P2,P3).

ALL DAY The timeswitch operates one `ON/OFF' period per day. This operates from the first `ON' time to the third 'OFF' time.

ON

The timeswitch is permanently ON.

OFF

The timeswitch is permanently OFF.

Press Select to change between AUTO, ALL DAY, ON & OFF.

The current mode will be shown on the screen.

The Select is found under the front cover.

EPH Controls Ltd.

11

Programming Modes
This timeswitch has the following programming modes. 5/2 Day mode Programming Monday to Friday as one block and
Saturday and Sunday as a 2nd block. 7 Day mode Programming all 7 days individually. 24 Hour mode Programming all 7 days as one block.

Factory Program Settings

5/2d

Mon-Fri Sat-Sun
All 7 days
Everyday

P1 ON 06:30 07:30
P1 ON 06:30
P1 ON 06:30

P1 OFF 08:30 10:00
P1 OFF 08:30
P1 OFF 08:30

5/2 Day P2 ON 12:00 12:00
7 Day P2 ON 12:00
24 Hour P2 ON 12:00

P2 OFF 12:00 12:00
P2 OFF 12:00
P2 OFF 12:00

12

R17V2

P3 ON 16:30 17:00
P3 ON 16:30
P3 ON 16:30

P3 OFF 22:30 23:00
P3 OFF 22:30
P3 OFF 22:30

Adjust the Program Setting in 5/2 Day Mode

Press PROG .

Programming for Monday to Friday is now selected.

Press and to adjust the P1 ON time.

Press OK .

Press and to adjust the P1 OFF time.

Press OK .

Repeat this process to adjust P2 and P3 times.

Programming for Saturday to Sunday is now selected.

Press and to adjust the P1 ON time.

Press OK .

Press and to adjust the P1 OFF time.

Press OK .

Repeat this process to adjust P2 and P3 times.

Press MENU to return to normal operation.

While in programming mode, pressing Select will jump to the next day (block of days) without changing the program.

Note:
1. To change from 5/2d to 7D or 24H programming, refer to page 16, Menu P01.
2. If you don't wish to use one or more of the daily programs then simply set the start time and end time to be identical. For example, if P2 is set to start at 12:00 and end at 12:00 the timeswitch will simply ignore this program and proceed to the next switching time.

EPH Controls Ltd.

13

Reviewing the Program Settings
Press PROG . Press OK to scroll through the periods for the individual day (block of days). Press Select to jump to the next day (block of days). Press MENU to return to normal operation.

Boost Function
The timeswitch can be boosted for 30 minutes, 1, 2 or 3 hours while it is in the AUTO, ALL DAY & OFF mode. Press Boost 1, 2, 3 or 4 times, to apply the desired BOOST period. When a Boost is pressed there is a 5 second delay before activation where `BOOST' will flash on the screen, this gives the user the time to select the desired BOOST period. To cancel a BOOST, press Boost again. When a BOOST period has ended or has been cancelled, the timeswitch will return to the mode that was previously active prior to the BOOST.
Note: A BOOST cannot be applied while in the ON or Holiday Mode.

14

R17V2

Advance Function
When the timeswitch is in the AUTO or ALLDAY mode, the Advance function allows the user to bring it forward to the next switching time.
If the timeswitch is currently timed to be OFF and ADV is pressed, it will be switched ON until the end of the next switching time. If the timeswitch is currently timed to be ON and ADV is pressed, it will be switched OFF until the start of the next switching time.
Press ADV .
The timeswitch will display `ADVANCE ON' or `ADVANCE OFF' until the end of the next switching time. To cancel an ADVANCE, press ADV again. When an ADVANCE period has ended or has been cancelled, the timeswitch will return to the mode that was previously active prior to the ADVANCE.

EPH Controls Ltd.

15

Menu
This menu allows the user to adjust additional functions. To access the menu, press MENU .
P01 Setting the Date, Time and the Programming Mode

DST ON

Press MENU , `P01 tInE' will appear on the screen. Press OK , the year will begin to flash. Press and to adjust the year. Press and to adjust the month. Press and to adjust the day. Press and to adjust the hour. Press and to adjust the minute. Press and to adjust from 5/2d to 7d or 24h mode. Press and to turn DST (Day Light Saving time) On or Off. Press MENU and the timeswitch will return to normal operation.
Note: Please see page 12 for descriptions of Programming Modes.

Press OK . Press OK . Press OK . Press OK . Press OK . Press OK .

16

R17V2

P02 Holiday Mode

This menu allows the user to switch off their heating system by defining a start and end date.

Press MENU , `P01' will appear on the screen.

Press until `P02 HOL' will appears on the screen.

Press OK , `HOLIDAY FROM', the date and time will appear on the screen. The year will begin to flash.

Press and to adjust the year.

Press OK .

Press and to adjust the month.

Press OK .

Press and to adjust the day.

Press OK .

Press and to adjust the hour.

Press OK .

`HOLIDAY TO' and the date and time will appear on the screen. The year will begin to flash.

Press and to adjust the year.

Press OK .

Press and to adjust the month.

Press OK .

Press and to adjust the day.

Press OK .

Press and to adjust the hour. The timeswitch will now be switched off during this selected period.

Press OK .

To cancel the HOLIDAY, press OK . The timeswitch will return to the normal operation when a holiday has finished or been cancelled.

EPH Controls Ltd.

17

Menu continued

P03 Frost Protection OFF

This menu allows the user to activate the frost protection between a range of 5°C and 20°C.

Frost protection is default set to OFF. Press MENU , `P01' will appear on the screen. Press until `P03 FrOST' appears on the screen. Press OK , `OFF' will appear on the screen.

Press to select `ON'. `5°C' will flash on the screen.

Press OK .

Press and to select your desired frost protection temperature.

Press OK .

Press MENU and the timeswitch will return to normal operation.

The Frost symbol will display on the screen if the user activates it in the menu.

If the ambient room temperature drops below the desired frost protection temperature, the timeswitch will activate and the frost symbol will flash until the frost protection temperature has been achieved.

18

R17V2

P04 Zone Title
This menu allows the user to select different titles for the timeswitch. The options are:

DEFAULT OPTION ZONE

RENAME OPTION 1 HEATING

RENAME OPTION 2 HOT WATER

Press MENU , `P01' will appear on the screen. Press until `P04' appears on the screen. Press OK , `ZONE' will flash on the screen. Press to change from `ZONE' to `HEATING' or `HOT WATER'. Press MENU and the timeswitch will return to normal operation.

EPH Controls Ltd.

19

Menu continued P05 PIN
This menu allows the user to put a PIN lock on the timeswitch. The PIN lock will reduce the functionality of the timeswitch. Set up the PIN
Press MENU , `P01' will appear on the screen. Press until `P05 PIn' appears on the screen. Press OK , `OFF' will appear on the screen. Press to change from OFF to ON. Press OK . `0000' will flash on the screen. Press and to set the value from 0 to 9 for the first digit. Press OK to move to the next PIN digit. When the last digit of the PIN is set, press OK . Verify is displayed with `0000'. Press and to set the value from 0 to 9 for the first digit. Press OK to move to the next PIN digit. When the last digit of the PIN is set, press OK . The PIN is now verified, and the PIN lock is activated.
If the verification PIN is entered incorrectly the user is brought back to the menu. When the PIN lock is active the Lock symbol will flash every second on the screen. When the timeswitch is PIN locked, pressing the menu will take the user to the PIN unlock screen. Note: When the PIN lock is enabled, BOOST periods are reduced to 30 minute and 1 hour periods. When the PIN lock is enabled, Mode Selections are reduced to Auto and OFF.

20

R17V2

To Unlock the PIN

Press MENU , `UNLOCK' will appear on the screen. `0000' will flash on the screen.

Press and to set the value from 0 to 9 for the first digit.

Press OK to move to the next PIN digit.

When the last digit of the PIN is set.

Press OK .

The PIN is now unlocked.

If a PIN has been unlocked on the timeswitch, it will automatically reactivate if there is no button pressed for 2 minutes.

To Deactivate the PIN

When the PIN is unlocked (see above instructions)

Press MENU , `P01' will appear on the screen.

Press until `P05 PIn' appears on the screen.

Press OK , `ON' will appear on the screen.

Press or to select `OFF'.

Press OK .

`0000' will flash on the screen. Enter the PIN.

Press OK .

The PIN is now disabled.

Press MENU to return to normal operation or it will automatically exit after 20 seconds.

EPH Controls Ltd.

21

Copy Function
Copy function can only be used when the 7d mode is selected. (See page 16 to select 7d mode) Press PROG to program the ON and OFF periods for the day for the week you want to copy. Do not press OK on the P3 OFF time, leave this period flashing. Press ADV , `COPY' will appear on the screen, with the next day of the week flashing. To add the desired schedule to this day press . To skip this day press . Press OK when the schedule has been applied to the desired days. Ensure the timeswitch is in the `Auto' mode for this schedule to operate accordingly.

22

R17V2

Backlight Mode Selection ON

There are 3 backlight settings available for selection:

AUTO Backlight stays on for 10 seconds when any button is pressed.

ON

Backlight is permanently On.

OFF

Backlight is permanently Off.

To adjust the backlight press and hold OK for 10 seconds. `Auto' appears on the screen. Press or to change the mode between Auto, On and Off. Press OK to confirm selection and to return to normal operation.

EPH Controls Ltd.

23

Locking the Keypad
To lock the timeswitch, press and hold and together for 10 seconds. will appear on the screen. The buttons are now disabled.
To unlock the timeswitch, press and hold and for 10 seconds. will disappear from the screen. The buttons are now enabled.

Resetting the Timeswitch
To reset the timeswitch to factory settings: Press MENU . `P01' will appear on the screen. Press until `P06 rESEt' appears on the screen. Press OK to select. `nO' will begin to flash. Press , to change from `nO' to `YES'. Press OK to confirm.
The timeswitch will restart and revert to its factory defined settings. The time and date will not be reset.

24

R17V2

Master Reset
To master reset the timeswitch to factory settings, locate the master reset button on the right-hand side underneath the timeswitch. (see page 5) Press the Master Reset button and release it. The screen will go blank and reboot. The timeswitch will restart and revert to its factory defined settings.
Service Interval OFF
The service interval gives the installer the ability to put an annual countdown timer on the timeswitch. When the Service Interval is activated `SErv' will appear on the screen which will alert the user that their annual boiler service is due.
For details on how to enable or disable the Service Interval, please contact customer service.