Honeywell Synoptique G2 System Overview
System Connectivity
The system utilizes a standard RTC telephone line and an external transmitter for communication. A connection harness links these components.
An RS232 serial interface is available for connecting to computers or printers.
Common Features (G2-20 and G2-44+ Systems)
Components shared across both G2-20 and G2-44+ alarm panels:
RS485 Bus Components
- Keypads: Up to 4 keypads can be connected, available with or without an integrated badge reader.
- CP037-50 (Keypad only)
- CP038-50 (Keypad with badge reader)
- Badge Reader: A standalone badge reader (x1).
- RIO Module: Provides 8 inputs and 4 outputs. Can be powered externally or housed in a unit (x4).
- Model: P026-50-B
- Connection: 8 inputs, 4 outputs
- Cable: Belden 8723 type, shielded, 2 twisted pairs or equivalent, up to 1km.
- Ethernet Module: Connects the system to an IP network (x1).
- Model: C072-50
- Cable: 4-wire, shielded, up to 100m.
- RF Portal: Radio communication module (x2).
- Model: C079-50-2
- Network: IP
Power and Software
- Battery: 12V power source.
- 17Ah for G2-44+
- 12Ah for G2-20
- Remote Servicing Suite (RSS): Software for remote system management, featuring a graphical interface.
Specific Features (G2-44+ System)
Components exclusive to the G2-44+ alarm panel:
ECP Bus Components
- Audio Module: Model TP2-800GY (x1).
- GSM Module: Model A231.
- Keypad 6160 ICON: Advanced keypad (x4).
- Model: 2012-172
- Expansion Module: Adds 8 inputs and 4 outputs (x3).
- Model: 2011-161
Honeywell Wired Detectors
A range of wired detectors compatible with the system:
- Intellisense® Passive Infrared (PIR) Detectors: IS21x Series.
- DUAL TEC® Detectors: DT7000 Series.
- Flexguard® Glass Break Detectors: FG1625TAS.
Wireless Detector Range
Wireless detectors compatible with Honeywell Galaxy and Domonial alarm panels:
- DT8M/DTPI8M DUAL TEC® Motion Detector
- FG8M Glass Break Detector
- SHK8M/SHKC8M Piezo Shock Detector
- DET8M Flood & Temperature Detector
- DO800M-A Miniature Door Contact
- IR8M/IRPI8M PIR Motion Detector (with pet immunity option)
- DFO800M Smoke Detector
- TCB800M Bi-directional Remote Control
Note: These wireless detectors require G2 panels with firmware version V1.5 or later.
For a complete list of radio and wired peripherals, please visit www.honeywell.com/security/fr.