Instruction Manual for The Home Depot models including: Z-17RIIUFA-4470 12-Light Modern Chandelier Lights, Z-17RIIUFA-4470, 12-Light Modern Chandelier Lights, Modern Chandelier Lights, Chandelier Lights, Lights

IMAGE FOR FINISHED PRODUCT: Page: - 1 - / 4

2 дня назад — WARNING (To reduce the risk of fire, electric shock, or personal injury):. 1. We suggest installation by a licensed electrician.

PDF preview unavailable. Download the PDF instead.

06783eec-74e0-4980-95cd-206fa2f634f6
Item Number: Z-17RIIUFA-4470 WARNING (To reduce the risk of fire, electric shock, or personal injury): 1. We suggest installation by a licensed electrician. 2. Please read the instruction carefully and save it as you may need it at a later time. 3. Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the "OFF" position.
» Place the wall switch in the "OFF" position. 4. Mounting surface should be clean, dry, flat, strong enough and 1/4" larger than the canopy on all sides.
Any gaps between the mounting surface and canopy exceeding 3/16" should be corrected as required. 5. Make sure that the ceiling or wall can stand the weight of the lamp before installation. 6. Make sure the voltage you are using is 120V. The maximum wattage is Type B,Max 40W per bulb. 7. Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp. 8. When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs
get hot quickly. 9. The safety instructions appearing in this manual are not meant to cover all possible conditions that may
occur. It must be understood that common sense, caution and care must be used with any electrical products. IMAGE FOR FINISHED PRODUCT:
Page:  1  / 4

TOOLS REQUIRED (NOT INCLUDED): Before starting assembly and installation please prepare the needed tools as below picture
PARTS TYPE & QTY INCLUDING: (C) Single bar (1) (D) Green ground screw (1) (E) Canopy (1) (F) Loop (4) (G) Hex nut (1) (H) Cap nut (1) (I) Quick link (2) (J) Tube (K) Shorter screw (4) (L) Flat iron stent (2) (M) Stem (2) (N) Upper frame (2) (O) Lower frame (2) (P) Longer screw (8) (Q) Sockets assembly (2) (R) Shorter pipe (24) (S) Longer pipe (36) (T) Nut (2) ACCESSORIES & QTY ENCLOSED: (A) Wire connector (3) (B) Mounting screw (2)
ASSEMBLY & INSTALLATION INSTRUCTIONS: 1. Carefully remove the fixture from the carton and check that all parts and accessories are
included as shown in the above illustration. 2. Make preinstallation
Page:  2  / 4

Step A1 » Screw stems (M) onto sockets assemblies (Q), then secure flat iron stents (L) with nuts (T).
By group, screw longer pipes (S) and shorter pipes (R) onto the same circle as shown above.
Step A2 » Insert lower frames (O) into flat iron stents (L), and secure them with shorter screws (K). Step A3 » Thread longer screws (P) into lower frame (O) and then into upper frame (N). Tighten till snug.
Step B1 » According to your desired fixture height, use and screw the chosen tubes (J) onto the top of flat iron
stents (L).
Step B2 » Attach quick links (I) to loops (F) on canopy (E) and tubes (J).
Carefully pass wires through loops (F) and canopy (E). Gently pull the wires to ensure the wires are not stressed. 3. Turn off power Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done. » Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the "OFF" position. » Place the wall switch in the "OFF" position. 4. Make installation
Page:  3  / 4

Step C1 » Unscrew hex nut (G) and cap nut (H) from single bar (C). Step C2 » Attach single bar (C) to the outlet box with mounting screws (B).
Note: the side of single bar (C) marked "GND" must face out.

Step C3 » If needed, shorten the length of fixture wires. At this point, the remaining wire length measured
above single bar (C) is at least 6".

Step C4 » Make wire connections
Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.

Connect ground wires according to the below chart

Connect wires according to the below chart

Twist wires together with plastic wire connectors until tightly joined, and wrap each connector with approved electrical tape. Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.
Step C5 » Raise canopy (E) to the ceiling and secure canopy (E) in place by tightening hex nut (G) and cap
nut (H) onto the preassembled threaded nipple on single bar (C).
NOTE: The canopy (E) should be snug against the ceiling and cap nut (H). If not, adjust the threaded length of the preassembled threaded nipple on single bar (C) by: · First, unscrew the preassembled hex nut · Then, screw the preassembled threaded nipple in or out of single bar
(C) · When the secure length is achieved, tighten the preassembled hex nut
and back to step C5.
Step C6 » Install bulbs (not included) (Please do not exceed the maximum wattage recommended on the
socket.)

5. Check everything is already installed properly, then you could turn on the light. Enjoy!

ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts.

CLEANING To clean, wipe the fixture with a soft cloth. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.
Page:  4  / 4