Omada by TP-Link

Installation Guide

RJ45 SFP Module

For technical support, replacement services, user guides, and more, please visit https://support.omadanetworks.com/.

Note: Images may differ from the actual products.

Installing the RJ45 SFP / RJ45 SFP+ Module

  1. Lock the yellow latch into place and insert the module into an SFP/SFP+ slot with the label side up.
  2. Gently push the module into the slot until you hear a click. Then, insert the RJ45 network cable.

Removing the RJ45 SFP / RJ45 SFP+ Module

  1. Press the RJ45 crystal head and pull out the cable.
  2. Pull down the latch and remove the module.

Positioning the 10G RJ45 SFP+ Modules

The 10G RJ45 SFP+ modules consume more power than optical modules, which may generate more heat. To avoid overheating, it is recommended to place the modules separated by multiple optical transceivers or empty slots. When used in high temperature environments, additional cooling must be applied.

The figures below only show the recommended positioning. The actual number of modules that can be inserted depends on the switch's heat dissipation and power margin.

Scenario 1:

Recommended: [Module] [Empty Slot] [Module]

Not Recommended: [Module] [Module] [Module]

Scenario 2:

Recommended: [Module] [Empty Slot] [Module]

Not Recommended: [Module] [Module] [Module]

Specifications

General Specifications

General Specifications SM331T SM5310-T
Model SM331T SM5310-T
IEEE 802.3 IEEE802.3i IEEE 802.3
IEEE 802.3u IEEEE 802.3u IEEE 802.3bz
IEEE 802.3ab IEEE 802.3ab IEEE 802.3ab
Standards and Protocols IEEE 802.3x, SFF-8472, INF 8074/SFP MSA SFF-8472, SFF-8431
MAC Interface 1000BASE-X XFI
Data Rate* (max.) 1.25 Gbps 10.3125 Gbps
Power Input 3.3 V 3.3 V
Power Consumption (max.) 0.8 W 2.5 W
Cable 100BASE-TX: UTP cat.5 or above (max. 100m)
1000BASE-T: UTP cat.5e or above (max. 100m)
10/5/2.5Gbps: UTP cat.5e or above (max. 100m)
10GBASE-T: UTP cat.6a or above (max. 30m)
RX LOS Yes Yes
TX_Fault Yes Yes
TX_Disable Yes Yes
LLF Yes Yes
LFP Yes Yes
DDM (temperature and voltage) Yes Yes
Hot Swappable Yes Yes

Compatibility

Model Gigabit SFP Slot (SFP Slot) 10G SFP+ Slot (SFP+ Slot)
SM331T Supported Supported**
SM5310-T Supported*** Supported***

We recommend using only Omada modules for your Omada devices. To find the compatible Omada devices for your module, please visit our website.

Notes:

Environmental and Physical Specifications

Environmental and Physical Specifications Value
Product Operating Temperature 0°C to 70°C (32°F to 158°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Operating Humidity 10% to 90% RH, Non-condensing
Storage Humidity 5% to 90% RH, Non-condensing

Safety Information

Declarations of Conformity

EU Declaration of Conformity

TP-Link hereby declares that the SFP module is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2011/65/EU and (EU)2015/863. The original EU declaration of conformity may be found at https://www.tp-link.com/en/support/ce.

UK Declaration of Conformity

TP-Link hereby declares that the SFP module is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016. The original UK Declaration of Conformity may be found at https://www.tp-link.com/support/ukca.

FCC compliance information statement

Product Name: 1000BASE-T RJ45 SFP Module/10GBASE-T RJ45 SFP+ Module

Model Number: SM331T/SM5310-T

Responsible party: TP-Link Systems Inc.

Address: 10 Mauchly, Irvine, CA 92618

Website: https://www.tp-link.com/us/

Tel: +1 626 333 0234

Fax: +1 909 527 6804

E-mail: sales.usa@tp-link.com

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

We, TP-Link Systems Inc., have determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.

Industry Canada Statement

CAN ICES-003 (A)/NMB-003(A)

CE Mark Warning

This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

Ukrainian Conformity Statement

Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам нормативних документів та вимогам, що передбачені чинними законодавчими актами України.

Explanation of the symbols on the product label

Note: The product label can be found at the bottom of the product. Symbols may vary from products.

Symbol Explanation
II Class II equipment
II with functional earthing Class II equipment with functional earthing
~ Alternating current
= Direct current
[DC polarity] Polarity of DC power connector
[indoor use] For indoor use only
[dangerous voltage] Dangerous voltage
[caution shock] Caution, risk of electric shock
[energy efficiency] Energy efficiency marking
[protective earth] Protective earthng
[earth symbol] Earth
[frame] Frame or chassis
[functional earth] Functional earthing
[caution hot] Caution, hot surface
[caution] Caution
[manual] Operator's manual
[stand-by] Stand-by
["ON"/"OFF"] "ON"/"OFF" (push-push)
[fuse] Fuse
[N fuse] N Fuse is used in neutral N
[recycling symbol] RECYCLING
[WEEE] This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment. Users have the choice to give their product to a competent recycling organization or to the retailer when they buy new electrical or electronic equipment.
[caution volume] Caution, avoid listening at high volume levels for long periods
[disconnection] Disconnection, all power plugs
[mini-gap switch] Switch of mini-gap construction
[micro-gap switch US] Switch of micro-gap construction (for US version)
[micro-gap switch other] Switch of micro-gap / micro-disconnection construction (for other versions except US)
[semiconductor switch] Switch without contact gap (Semiconductor switching device)
Models: SM331T SFP Module, SM331T, SFP Module, Module

File Info : application/pdf, 2 Pages, 3.51MB

PDF preview unavailable. Download the PDF instead.

7100001187 SM5310-T(UN)3.0 multi-model IG

References

Adobe PDF library 15.00 Adobe Illustrator(R) 24.0

Related Documents

Preview TP-Link RJ45 SFP / RJ45 SFP+ Module Installation Guide
Installation guide for TP-Link TL-SM331T and TL-SM5310-T RJ45 SFP and SFP+ modules, covering installation, removal, positioning, specifications, and safety information.
Preview TP-Link TL-FM331/TL-FM531 RJ45 SFP/SFP+ Module Installation Guide
Comprehensive installation guide for TP-Link TL-FM331 and TL-FM531 RJ45 SFP/SFP+ modules, covering installation, removal, positioning, specifications, and safety information.
Preview TP-Link Omada SM5310-T 10G BASE-T RJ45 SFP+ Module Datasheet
Datasheet for the TP-Link Omada SM5310-T, a 10G BASE-T RJ45 SFP+ module that converts SFP+ ports to RJ45 ports, supporting multi-rate Ethernet speeds up to 10 Gbps over distances up to 30 meters with UTP Cat6a or higher cables. Features DDM and hot-pluggable design.
Preview TP-Link Omada SM321B: 1000Base-BX WDM Bi-Directional SFP Module Datasheet
Datasheet for the TP-Link Omada SM321B, a 1000Base-BX WDM Bi-Directional SFP Module designed for extending network distances up to 20km over a single strand of fiber, offering high speed and stability.
Preview TP-Link Omada SM5110LSB-10 SFP+ LC Module Datasheet
Datasheet for the TP-Link Omada SM5110LSB-10, a 10GBase-BX WDM Bi-Directional SFP+ LC Module supporting single-mode fiber, hot-plugging, and DDM.
Preview TP-Link Omada ER7406 Gigabit VPN Gateway Datasheet
Explore the TP-Link Omada ER7406, a high-performance Gigabit VPN Gateway designed for secure and flexible network connectivity. Features include dual-core processor, multiple VPN protocols, load balancing, and robust lightning protection.
Preview TP-Link Omada Multi-Gigabit VPN Router ER707-M2 Datasheet
Datasheet for the TP-Link Omada ER707-M2 Multi-Gigabit VPN Router, detailing its specifications, features, performance, and ordering information.
Preview TP-Link SM321A 1000Base-BX WDM Bi-Directional SFP Module Datasheet
Datasheet for the TP-Link SM321A, a 1000Base-BX WDM Bi-Directional SFP module supporting up to 20Km over a single strand of fiber. Features LC Simplex, DDM, and hot-swappable capabilities.