Installation Instructions

READ BEFORE INSTALLING UNIT

Compact Window Mounting (10,000~12,000 BTU)

INSTALLATION WARNINGS AND CAUTION

To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

NOTE:

The top rail on your unit may already be installed. If not, follow the steps below.

Mounting Hardware

Mounting HardwareQty.
1/2" screws7
lock frame (For Wooden windows)2
lock frame (For Vinyl-Clad windows)2
sash lock1
weather seals (6"X3/4"X1/12")5
window sash seal foam1

Top Rail Hardware

Top Rail HardwareQty.
3/8" Screw4
Top Rail1

TOOLS NEEDED

Before installing, the top rail must be assembled on the unit.

  1. Remove the air conditioner from the carton and place on a flat surface.
  2. Remove top rail from the rear of the packaging material as shown in Fig. A.
  3. Align the hole in the top rail with those on the top of the unit as shown in Fig. B.
  4. Secure the top rail to the unit with the 3/8" Screws as shown in Fig. C.

LEFT + RIGHT FILLER PANEL ASSEMBLY

NOTE: Top Rail and Side Panels at each side are offset to provide the proper pitch to the rear of (5/16"). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained!

  1. Place unit on floor, a bench or a table. There is a Left and Right side Filler Panels - be sure to use the proper panel for each side. When installed, the flange for securing the panel in place to the window sill will be facing into the room.

A. Hold the side Panel in one hand and gently pull back the center to free the open end. See FIG. 1.

B. Slide the free end “I” section of the panel directly into the cabinet as shown in FIG. 2. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.

C. Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. See FIG. 3.

D. Slide the panel all the way in and repeat on the other side.

Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches (584 mm to 914 mm) (FIG. 4A, FIG. 4B). Lower sash must open sufficiently to allow a clear vertical opening of 15-1/2 inches (394 mm ). Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage.

Storm Window:

If the air conditioner is blocked by Storm Window, add wood as shown in FIG. 5, or remove storm window before air conditioner is installed. If Storm Window Frame must remain, be sure the drain holes or slots are not caulked or painted shut. Accumulated Rain Water or Condensation must be allowed to drain out.

Installation

  1. Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (FIG. 6A & FIG. 6B). Carefully close the window behind the top rail of the unit.
  2. Extend the side panels out against the window frame (FIG. 7A for wooden windows), (FIG. 7B for Vinyl-Clad windows).
  3. Place the frame lock between the frame extensions and the window sill as shown (FIG. 8A for wooden windows), (FIG. 8B for Vinyl-Clad windows).
  4. Drive locking screws:

A: For wooden windows: Drive 1/2" (12.7 mm) locking screws through the frame lock and into the sill (FIG. 9A). NOTE: To prevent window sill from splitting, drill 1/8" (3mm) pilot holes before driving screws. Drive 1/2" (12.7 mm) locking screws through frame holes into window sash (FIG. 9B).

B: For Vinyl-Clad windows: Drive 1/2" (12.7 mm) locking screws through the frame lock and into the window sash (FIG. 9B). NOTE: Before driving the screws, use a drill to drill 5 holes through the holes in the frame lock and frame extensions into the windows sash as shown (FIG. 9B).

  1. To secure lower sash in place, attach right angle sash lock with 1/2" (12.7mm) screw as shown (FIG. 10). NOTE: It is difficult to lock the windows with the sash lock for Vinyl-Clad windows, so you can use lock by window itself.
  2. Cut foam window seal and insert it into the space between the upper and lower sashes (FIG. 11).
  3. After the completion of the installation, please check the machine's lean as shown (FIG. 12A & FIG. 12B). It's necessary for proper condensed water utilization and drainage.
  4. Trim the weather seal (6"X3/4"X1/12") with a proper length, peel off the protective backing and plug any gaps if needed as shown FIG.13.

Removing the air conditioner From Window

PDF preview unavailable. Download the PDF instead.

2020215a0562 Acrobat Distiller 7.0 (Windows)

Related Documents

Preview Frigidaire Compact Window Air Conditioner Installation Guide
Comprehensive installation instructions for Frigidaire compact window air conditioners (10,000-12,000 BTU), covering mounting hardware, assembly, storm window considerations, and final checks for proper operation and drainage.
Preview Frigidaire Compact Window Air Conditioner Installation Guide
This guide provides comprehensive installation instructions for Frigidaire compact window air conditioners (12,000-14,000 BTU). It includes essential warnings, cautions, lists of mounting hardware and tools, and detailed step-by-step procedures for installing the unit in various window types, along with tips for storm windows, tilt adjustment, and unit removal.
Preview Frigidaire WD Window Air Conditioner Installation Guide
Step-by-step installation instructions for the Frigidaire WD Window Mounting Air Conditioner (8,000-10,000 BTU). Covers safety, hardware, assembly, and removal procedures.
Preview Frigidaire FHSC102WB1 10,000 BTU Slider Casement Window Air Conditioner Specifications
Detailed specifications for the Frigidaire FHSC102WB1, a 10,000 BTU slider casement window room air conditioner. Includes performance data, electrical specifications, general features, dimensions, and available accessories.
Preview Frigidaire Compact Window Air Conditioner Installation Guide
Step-by-step instructions for installing a Frigidaire compact window air conditioner (10,000-14,500 BTU), including safety warnings, hardware lists, and mounting procedures.
Preview Frigidaire FFRA102WAE Window Air Conditioner Specifications
Detailed specifications for the Frigidaire FFRA102WAE 10,000 BTU Window-Mounted Room Air Conditioner, including performance, dimensions, electrical, and safety certifications.
Preview Frigidaire FFRE1033Q1 Compact Window Air Conditioner Installation Instructions
Step-by-step installation guide for the Frigidaire FFRE1033Q1 compact window air conditioner, covering mounting, hardware, and removal.
Preview Frigidaire Compact Window Air Conditioner Installation Guide
Comprehensive installation instructions for Frigidaire compact window air conditioners (8,000-12,000 BTU), covering mounting, bracket setup, and final checks for optimal performance and safety.