Corbin Russwin IN120 WiFi/IN220 PoE Mortise Lockset Installation Instructions

Attention Installer:

Please read these instructions carefully to prevent missing important steps. Improper installations may result in damage to the lock and void the factory warranty. The accuracy of the door preparation is critical for proper functioning and security of this lock. Misalignment can cause premature wear and a lessening of security.

For specific security information, please contact your local ASSA ABLOY Door Security Solutions sales consultant or call 800-810-9473.

Warning: This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm. For more information go to: www.P65warnings.ca.gov.

Avertissement: Ce produit peut vous exposer au plomb qui, dans l'état de la Californie, est reconnu pour causer le cancer, des anomalies congénitales ou d'autres problèmes de reproduction. Pour plus d'informations, visitez: www.P65warnings.ca.gov.

Contact: 1-800-810-9473, techsupport.corbinrusswin@assaabloy.com

Copyright © 2016, 2021, 2025, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved.

Table of Contents

  1. Warning
  2. Regulatory and Power Specifications
    • Electronic Authentication Specifications (Mobile Credentials)
    • Power Supply Specifications
  3. Product Illustrations
    • IN120/220 Assembly
    • Mortise Lock
  4. IN220 PoE Installation Wiring
  5. Lock Installation
    • Prepare Door
    • Install Door Position Switch (DPS)
    • Prepare Lock Body
    • Install Lock Body
    • Install Outside Cylinder
    • Install Turn Piece
  6. IN120/220 Installation
    • Outside Reader Installation
    • Inside Mounting Plate Installation
    • Installation of Connectors
    • Installing the Controller
    • Supplying Power to the Controller
    • Inside Cover Installation
  7. Operational Check

1. Warning

Changes or modifications to this device not expressly approved by ASSA ABLOY could void the user's authority to operate the equipment.

FCC:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

The card reader shall be installed and used such that parts of the user's body other than the hands are maintained at a distance of approximately 20 cm (8 inches) or more.

Innovation, Science and Economic Development Canada:

Under Innovation, Science and Economic Development Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

Conformément à la réglementation d'Innovation, Sciences et Développement économique Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.

General Regulatory Compliance:

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device.

Ce dispositif contient des émetteurs/réceptuers exemptés de licence conformes aux RSS d'Innovation, Sciences et Développment économique Canada. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée a le dispositif.

This equipment complies with FCC and IC radiation exposure limits set forth for general population (uncontrolled environment). This device must not be co-located or operating in conjunction with any other antenna or transmitter.

Cet équipement est conforme aux limites d'exposition aux radiations de la FCC et IC définies pour la population générale (environnement non contrôlé). Cet appareil ne doit pas être co-localisé ou fonctionner en conjonction avec une autre antenne ou un autre émetteur.

CAUTION: When using hard power, DO NOT install batteries.

AVERTIR: Ne pas installer de batteries si vous utilisez l'alimentation électrique.

CAUTION: Risk of Explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

AVERTIR: Risque d'explosion si la batterie est remplacée par un type incorrect. Jetez le batteries usagées conformément aux instructions.

Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.

ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES

To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components:

2. Regulatory and Power Specifications

Electronic Authentication Specifications (Mobile Credentials)

This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70.

Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL294/B.

The system shall not be installed in the fail-secure mode unless permitted by the local authority having jurisdiction and shall not interfere with the operation of listed panic hardware.

Reader with HID® OMNIKEY® reader core technology offers support for the following credentials:

High Frequency (13.56 MHz): Low Frequency (125 kHz):
• HID iCLASS® • HID Prox®
• HID ICLASS SE® (SIO-enabled) PIV/PIV-1:
• HID iCLASS® Seos™ • 40-bit BCD
• HID MIFARE® SE • 64-bit BCD
• HID DESFire® EV1 SE • 75-bit output
• HID MIFARE Classic SE • 128-bit output
• DESFire EV1 • 200-bit output
• DESFire EV2/EV3 (EV1 Compatibility)

NFC & BLE-enabled Mobile Phones:

Optional Keypad:

UL Listings:

UL 294 Access Control Ratings:

Level 1 Level 4
Destructive Attack Level 1
Line Security Level 1
Endurance Level 1
Standby Power Level 1

Power Supply Specifications

IN120 (WiFi version):

CAUTION: When using Hard Power, DO NOT install batteries.

CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

IN220 (PoE version):

Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety Standard for Electrical Installations, local codes and the authorities having jurisdiction. Equipment installed in outdoor use applications shall employ NEC Class 3 wiring methods.

3. Product Illustrations

IN120/220 Assembly

Tools Required:

Item No. Description
1* Reader Assembly (keypad version optional)
2 Mounting Plate Assembly (includes gasket)
3a PoE Controller Assembly
3b WiFi Controller Assembly* (Batteries Included)
4 AA Alkaline Batteries (6)
5 Inside Escutcheon Assembly with Privacy Button
6 Door Position Switch (optional)

See document FM646 for part numbers.

Prior to installation, please confirm receipt of all parts.

Note: To comply with Fire Listed doors, the batteries must be replaced with alkaline batteries ONLY.

Mortise Lock

For parts not listed, refer to ML2000 Parts and Service Manual.

Tools Required:

Item No. Description Req'd
1* ML20133/ML20134 Lock Case - No Deadbolt 1
ML20135/ML20136 Lock Case - With Deadbolt
ML20233/ML20234 Lock Case - No Deadbolt (not shown)
ML20235/ML20236** Lock Case - With Deadbolt (not shown)
2 Door Position Switch (Optional) 1

*Replacing with handing (L, LR, R, RR)

**Required for Escape Return Functionality (a residential requirement in canada)

***Not required for ML202xx

4. IN220 PoE Installation Wiring

Corbin IN220 PoE Typical Application

Components: EAC Software System, Network Switch (802.3af), Network Cable, Surface Mount RJ45.

Installation Steps:

  1. PoE frame harness assembly
  2. PoE data hinge from McKinney
  3. PoE door harness* from McKinney
  4. IN220 PoE Lock
  5. For locks with external DPS (Door Position Switch)

*Door width determines length

Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction.

Installation Overview (continued)

Supplied by CI: B-Splice Crimp Connector, RJ45-M, Patch Cable, Patch Cable to PoE Switch.

Wiring Diagram:

TIA/EIA 568-B Standard Wiring:

Pin Wire Pair Number
1 White/Orange 2
2 Orange 2
3 White/Green 3
4 Blue 1
5 White/Blue 1
6 Green 3
7 White/Brown 4
8 Brown 4

Note: Do not confuse pair numbers with pin numbers. A pair number is used for reference only (e.g., 10BaseT Ethernet uses pairs 2 & 3). The pin numbers indicate actual physical locations on the plug and jack.

Hinge side of PoE (Frame) harness:

  1. Feed cut end of harness into hole on hinge-side through single access hole.
  2. Push one connector back through the hole and feed into the other access hole.

Each of the hinge-side harness connectors should end up threaded through a different access hole and matched to the same size pin connector from the door harness:

2. PoE Data Hinge

Frame: 4-pin F, 4-pin M, 6-pin M, 6-pin F.

PoE Hinge: 4-pin F, 4-pin M, 6-pin M, 6-pin F.

Hinge-side harness connectors:

Lock-side harness connectors:

3. PoE Door Harness

Order of installation may vary. Refer to appropriate sections for instructions.

Hinge-side harness connectors:

Lock-side harness connectors:

NOTES:

Wiring Diagram:

4. PoE Lock

Order of installation may vary. Refer to appropriate sections for instructions.

  1. Prop door open.
  2. Using the ring terminal, carefully route the assembly through the door channel toward lock.

IMPORTANT: DO NOT TERMINATE POE HARNESS (WITH RJ45 M) UNTIL CABLE HAS BEEN ROUTED THROUGH DOOR AND INSIDE MOUNTING PLATE ASSEMBLY.

See Section 6.3, Installation of Connectors.

5. Lock Installation

1. Prepare Door

Illustrations shown are as viewed from outside or secure side of opening. (Figure 5-1A)

A. Verify Hand and Bevel of Door.

B. Verify exit device is correct hand for door.

C. Verify Product Label.

D. Door Preparation: mark and drill door.

Outside of Door:

Inside of Door:

2. Install Door Position Switch (DPS)

Wood doors have 3/8" raceway to controller cutout and metal doors have 3/4" raceway to the controller cutout.

Refer to template (ships with product): MEFT18 (MEFT26 for EA option)

  1. Insert connector end of DPS through the raceway on the latch edge of the door. (Figure 5-2)
  2. NOTE: For metal doors, use DPS Collar.
  3. Push DPS firmly into place by hand.

IMPORTANT: DO NOT USE ANY TOOLS TO TAP THE SWITCH; DOING SO MAY CAUSE DAMAGE.

3. Prepare Lock Body

  1. Move red locking to side of lockbody being locked. (Figure 5-3A)
  2. Push in latch partially then depress catch plate with screwdriver. (Figure 5-3A)
  3. Pull latch out of lockbody and rotate 180 degrees. (Figure 5-3B)
  4. Push in latch until tailpiece hits back of case. (Figure 5-3C)
  5. NOTE: Make sure catch plate is even with top surface and locking pin is not projected. (Figure 5-3D) If not, depress catch plate with screwdriver and repeat step 4.
  6. Rotate lock front to match bevel of door as shown. (Figure 5-3E)

4. Install Lock Body

  1. Feed wires through 1-5/16" diameter hole on inside of door while installing lockbody. (Figure 5-4A)
  2. Pull wires through hole while inserting lockbody. Do not push wires back into cylinder hole. (Figure 5-4B)
  3. IMPORTANT: Door must remain open during installation. Use door stop.
  4. Install, but do not tighten two (2) #12 x 1" combination screws through lockbody. (Figure 5-4A)

5. Install Outside Cylinder

  1. Slide cylinder through collar. Thread cylinder into lockbody. (Figure 5-5B)
  2. Rotate the cylinder into cylinder hole with fingers.
  3. Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole.
  4. IMPORTANT: Do not attempt to tighten all the way.
  5. Verify that orientation of cylinder has the Corbin Russwin logo as depicted in Figure 5-5A.
  6. Hand tighten the cylinder clamp screw with Phillips screwdriver to prevent unscrewing of the cylinder (Figure 5-5C).
  7. Test cylinder function:
    • Key retracts latchbolt and deadbolt (7976 & 82276 function)
    • Key retracts latchbolt (7978 & 82278 function)
    • Cylinder not present for 7977, 7979, 82277 or 82279 functions

For Standard Lever Trim

Outside of Door: Outside Adapter Plate

Inside of Door:

7. Align adjustment bolt with threaded hole in lever.

8. Install I/S lever with set screw.

For Museo® Trim

  1. Thread adapter plate hub into lever and fully tighten. (Figure 5-5P)
  2. NOTE: Spindle can be used to help thread hub into lever.
  3. Align adapter plate hub with square hole in lever; keeping hub as tight as possible. (Figure 5-5Q)
  4. Install outside trim assembly and inside adapter plate. (Figure 5-5R)

6. Install Turn Piece

6. IN120/220 Installation

1. Outside Reader Installation

  1. Orient reader so LED lens is at the top.
  2. Feed the cable/connector through the door (from outside to inside).
  3. Install reader to the outside of the door by aligning mounting posts with the door preparation holes. Hold reader flush against door while ensuring proper alignment.

2. Inside Mounting Plate Installation

  1. Feed cables/connectors through the inside controller mounting plate assembly (and gasket if required*).
  2. IMPORTANT: Door must remain open during installation. Use door stop.
  3. Tuck excess cable into wire hole on inside of door.
  4. Insert and partially tighten two (2) through-bolts prior to installation of connectors.
  5. Secure ground lug(s) with #6-32 machine screw. (Figure 6-2A)

*Gasket is required for outdoor installations.

NOTE: Do not use gasket for fire-rated openings.

NOTE: If installing with gasket, separate gasket from controller mounting plate to feed cables/connectors through holes as indicated (Figure 6-2B). Once cables/connectors are fed through, reattach gasket to controller mounting plate.

NOTE: Cable lengths exaggerated for illustrative purposes.

3. Installation of Connectors

CAUTION:

  1. Snip end of packet to dispense grease.
  2. Ensure all connector pins and contacts (Figure 6-3A) are covered. (Do not overfill or over-apply**)

    *Supplied tube contains 5 grams of silicone dielectric compound (grease)

    **Evenly distribute grease; full application requires approximately 2.5 grams

  3. IMPORTANT: Do not run wires through bottom flange hole in plate - it will damage wires and controller connector. Route wires around flange (See Figures 6-3A - 6-3B).
  4. Secure the following connectors (Figure 6-3B, Figure 6-3C).
    • A. Secure the 4-pin DPS connector.
    • B. Secure the 10-pin lock body assembly connector.
  5. Secure mounting plate.
    • Tuck excess cable into wire hole on inside of door.
    • Secure the mounting assembly while ensuring proper alignment of outside reader and fully tighten the (2) through-bolts on the inside of the door to secure the reader and plate to the door.
    • C. Secure the 24-pin card reader connector. (Figure 6-3B, Figure 6-3C)
    • D. Ensure all openings on back of secured reader connector are covered completely with grease. (Figure 6-3C)

4. Installing the Controller

If installing IN220 (PoE)*

  1. Strip Ethernet cable jacket (3) inches.
  2. Separate (untwist) and straighten (8) Ethernet wires before carefully feeding through ferrite bead (Figure 6-3D).
  3. Crimp RJ45 (male) connector on end of wires.

*For more detail, refer to Section 4 IN220 PoE Installation Wiring "1 - Frame Harness Installation".

CAUTION:

  1. Insert bottom tab of controller (ensure a clear path) into slot on mounting plate (Figure 6-4D, Figure 6-4E).
  2. Ensure proper alignment of board-to-board connectors (Figure 6-4E) while pivoting controller toward door until two tabs on top click securely into place on mounting plate. (Figure 6-4D)

CAUTION: To avoid possible damage to board-to-board connectors, care should be taken when securing controller to mounting plate. If there is resistance when securing, detach controller to determine cause before re-attaching controller.

5. Supplying Power to the Controller

NOTE: Before inserting PoE plug into connector, apply dielectric grease to top of plug, covering the pin area. (Figure 6-5A)

A. IN220 (PoE)

  1. Once controller is securely in place, connect RJ45 male connector to female RJ45 port on controller board. (Figure 6-5A)
  2. If power is enabled, LED will flash, and lock motor will cycle.

B. IN120 (WiFi)

  1. Once controller is securely in place, place (6) "AA" alkaline batteries in the compartment, being careful to align polarity properly. (Figure 6-5B)
  2. After batteries are installed, there is a slight delay; LED will flash and the lock motor will cycle.

6. Inside Cover Installation

  1. Assemble cover by hooking top edge on inside mounting plate taking care not to pinch gasket (top edge goes between plate and gasket). (Figure 6-6A)
  2. Carefully press bottom of cover toward door without pinching any wires.
  3. Secure the cover with a Security Allen key. (Figure 6-6A)

NOTE: Use of power tools on this step is strongly discouraged. Over-torquing security pin hex screw will result in battery cover damage.

7. Operational Check

When lock is fully installed, perform the following steps:

IMPORTANT: Be sure to test functions prior to closing door.

  1. Insert key into cylinder and rotate. There should be no friction against lock case, wire harness or any other obstructions.
  2. Check that the key retracts the latch; the key should rotate freely.
  3. Throw the deadbolt (if present); check that the key retracts both the deadbolt and the latch.
  4. Try the inside lever; ensure it retracts latch (if installed).
  5. Use a valid credential* set up with the Lock Configuration Tool to unlock outside lever and retract latch.

Refer to Network and Lock Configuration Tool user manual (WFMN1) for information on how to configure and program locks.

*Twenty (20) seconds after lock initialization (single beep with lock motor actuation).

In all cases, perform the following checks:

LED signalling:

*Refer to Lock Configuration Tool user manual (WFMN1) for information on how to configure and program locks.

Models: MODBLE9163K, U4A-MODBLE9163K, U4AMODBLE9163K, IN120 WiFi Mortise Lockset, IN120 WiFi, Mortise Lockset, Lockset

File Info : application/pdf, 28 Pages, 4.67MB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8503001

References

Adobe PDF Library 17.0

Related Documents

Preview Corbin Russwin IN120 WiFi & IN220 PoE Cylindrical Lockset Installation Guide
Comprehensive installation instructions for Corbin Russwin IN120 WiFi and IN220 PoE cylindrical locksets. Covers product overview, hardware, electronic specifications, wiring, installation steps, and operational checks for secure access control solutions.
Preview Corbin Russwin IN120 WiFi and IN220 PoE Exit Device Installation Instructions
Comprehensive installation guide for Corbin Russwin IN120 WiFi and IN220 PoE exit devices (ED5200(S)N & ED5600N Series), covering rim and mortise installations, wiring, and operational checks for models including 9100/9M100.
Preview Corbin Russwin IN120 WiFi / IN220 PoE Installation Instructions
Comprehensive installation guide for Corbin Russwin IN120 WiFi and IN220 PoE multi-point locksets, covering door preparation, wiring, lock body installation, and operational checks.
Preview Corbin Russwin IN120 WiFi/IN220 PoE EcoFlex CLX33100 Installation Instructions
Detailed installation instructions for the Corbin Russwin IN120 WiFi and IN220 PoE EcoFlex CLX33100 smart lock, covering product illustrations, wiring, lock installation, and operational checks.
Preview Corbin Russwin IN120 WiFi / IN220 PoE Installation Instructions
Comprehensive installation guide for Corbin Russwin IN120 WiFi and IN220 PoE exit devices, covering various models like PED5200, PED5400, PED5600, and PED5800 series. Includes detailed steps for preparation, wiring, component installation, and operational checks.
Preview Corbin Russwin IN120 WiFi/IN220 PoE Installation Instructions
Comprehensive installation guide for Corbin Russwin IN120 WiFi and IN220 PoE exit devices, including ED5200 (S)N & ED5600N Series Rim and Mortise models. Covers wiring, assembly, and operational checks.
Preview Corbin Russwin ML2000 Series Mortise Locks: M, N, and P Escutcheon Trim Installation Instructions
Detailed installation instructions for Corbin Russwin ML2000 Series Mortise Locks, covering M, N, and P Escutcheon Trims, including handing, escutcheon installation, and specific notes for different configurations. Features ASSA ABLOY security technology.
Preview Corbin Russwin ML20600 Series Mortise Lock Installation Instructions
Comprehensive installation guide for the Corbin Russwin ML20600 Series Mortise Lock with iCLASS SE® Reader Option. Covers general description, features, regulatory specifications, product illustrations, wiring diagrams, installation steps, and operational checks.