By operating in accordance with ESG principles, Kaisai aims to reduce the negative impact of its operations on the environment while creating value for its stakeholders, including employees, customers, local communities, and investors. The company is committed to conducting business ethically and responsibly, placing great importance on transparency and corporate responsibility to enhance the trust and loyalty of its stakeholders.
Air Conditioners
FLY
Split air conditioner wall mounted
Specification
- Cooling capacity: 2.6/3.5/5.3/7.0 kW
- Heating capacity: 2.9/3.8/5.6/7.3 kW
- Refrigerant: R32
- Energy efficiency class: A++/A+
- SEER: up to 7.4
- SCOP: up to 4.1
- Cooling operating temperature range: -15~50°C
- Heating operating temperature range: -25~30°C
Functions
- ? Wi-Fi module
- ? Bio Hepa filter
- ?️ Cold catalyst filter
- ? 3D airflow
- ♨️ Compressor and condensate tray heaters
ICE / ICE BLACK
Split air conditioner wall mounted
Specification
- Cooling capacity: 2.6/3.5/5.3/7.0 kW
- Heating capacity: 2.9/3.8/5.6/7.3 kW
- Refrigerant: R32
- Energy efficiency class: A+++/A++
- SEER: up to 8.8
- SCOP: up to 4.6
- Cooling operating temperature range: -15~50°C
- Heating operating temperature range: -25~30°C
Functions
- ? Wi-Fi module
- ? Bio Hepa filter
- ?️ Cold catalyst filter
- ? 3D airflow
- ♨️ Compressor and condensate tray heaters
- [Wired controller (optional)]
- [Central controller (optional)]
GEO
Split air conditioner wall mounted
Specification
- Cooling capacity: 2.6/3.5/5.3/7.0 kW
- Heating capacity: 2.9/3.8/5.6/7.3 kW
- Refrigerant: R32
- Energy efficiency class: A+++/A++
- SEER: up to 9.3
- SCOP: 4.6
- Cooling operating temperature range: -15~50°C
- Heating operating temperature range: -25~24°C
Functions
- ? Wi-Fi module
- ? Bio Hepa filter
- ⚡ Air ionization
- ? 3D airflow
- ?️ Cold catalyst filter
- ♨️ Compressor and condensate tray heaters
NORDIC
Split air conditioner wall mounted
Specification
- Cooling capacity: 3.5 kW
- Heating capacity: 3.8 kW
- Refrigerant: R32
- Energy efficiency class: A+++/A+++
- SEER: 9.2
- SCOP: 5.1
- Cooling operating temperature range: -15~50°C
- Heating operating temperature range: -35~30°C
Functions
- ? Wi-Fi module
- ?️ Sterilisation 56°C
- ⚡ Air ionization
- ? 3D airflow
- ♨️ Compressor and condensate tray heaters
- ? Fireplace function
PRO HEAT+
Split air conditioner wall mounted
Specification
- Cooling capacity: 2.6/3.5/5.2/7.0 kW
- Heating capacity: 3.0/3.8/5.5/7.1 kW
- Refrigerant: R32
- Energy efficiency class: A+++/A++
- SEER: up to 8.5
- SCOP: up to 4.7
- Cooling operating temperature range: -15~50°C
- Heating operating temperature range: -25~30°C
Functions
- ? Wi-Fi module
- ? Silver ion filter
- ⚡ Air ionization
- ? 3D airflow
- ♨️ Condensate tray heater
- ❄️ Gentle Cooling function
- ? UVC lamp
CONSOLE TYPE
air conditioner
Specification
- Cooling capacity: 3.5/5.0 kW
- Heating capacity: 3.8/5.3 kW
- Refrigerant: R32
- Energy efficiency class: A++/A+
- SEER: up to 7.3
- SCOP: 4.0
- Cooling operating temperature range: -15~50°C
- Heating operating temperature range: -15~24°C
Functions
- ? WiFi module (option)
- ?️?️ 2 air outlets
- ♨️ 8°C continuous heating
- ♨️ Compressor and condensate tray heaters
Other Air Conditioner Types
- Cassette air conditioners (KCA/KCD)
- Floor/ceiling air conditioners (KUE)
- Duct air conditioners (KTI)
- Multi-split air conditioners
- Floor air conditioners
Heat Pumps
KHC
Air-to-water heat pump R32 monoblock
Specification
- Nominal capacity: 6/8/10/12/14/16 kW
- Electric auxiliary heater: 3/6/9 kW
- Refrigerant: R32
- Energy efficiency class (heating 35°C/55°C): A+++/A++
- COP: up to 5.15
- Water leaving temp. - heating: 25~65°C
- Water leaving temp. - cooling: 5~25°C
- Outlet water temp. - DHW: 25~60°C
- Outdoor air temp. range - heating: -25~35°C
- Outdoor air temp. range - cooling: -5~43°C
- Outdoor air temp. range - DHW: -25~43°C
Functions
- ? Wireless Wi-Fi operation
- ? Modbus RTU protocol
- ⚡ Additional electric heater
- ♨️♨️ Operation of 2 heating circuits
KHY
Air-to-water heat pump R290 monoblock
Specification
- Nominal capacity: 12/15 kW
- Refrigerant: R290
- Energy efficiency class (heating 35°C/55°C): A++/A++
- COP: up to 4.45
- Water outlet temperature - heating: 9~70°C
- Outlet water temperature - cooling: 5~15°C
- Outdoor air temp. range - heating: -25~43°C
- Outdoor air temp. range - cooling: -5~43°C
Functions
- ♨️♨️ Operation of 2 heating circuits
- ❄️⚙️ Intelligent defrost
- ? Soundproof isolation
- ?️ Shock absorption
- ? Intuitive control
KMK / KHA with DHW tank
Air-to-water heat pump R32 split with DHW tank
Specification
- Nominal capacity: 6/8/10/12/14/16 kW
- Electric auxiliary heater: 3/6/9 kW
- Refrigerant: R32 (Czynnik chłodniczy: R32)
- Energy efficiency class (heating 35°C/55°C): A+++/A++
- COP: up to 5.15
- Water leaving temp. - heating: 25~65°C
- Water leaving temp. - cooling: 5~25°C
- Outlet water temp. - DHW: 25~60°C
- Outdoor air temp. range - heating: -25~35°C
- Outdoor air temp. range - Cooling: -5~43°C
- Outdoor air temp. range - DHW: -25~43°C
Functions
- ? Wireless Wi-Fi operation
- ? Modbus RTU protocol
- ⚡ Additional electric heater
- ♨️♨️ Operation of 2 heating circuits
- 190L/240L Stainless steel tank
KMK / KHA
Air-to-water heat pump R32 Split
Specification
- Nominal capacity: 6/8/10/12/14/16 kW
- Electric auxiliary heater: 3/6/9 kW
- Refrigerant: R32 (Czynnik chłodniczy: R32)
- Energy efficiency class (heating 35°C/55°C): A+++/A++
- COP: up to 5.20
- Water leaving temp. - heating: 25~65°C
- Water leaving temp. - cooling: 5~25°C
- Outlet water temp. - DHW: 30~60°C
- Outdoor air temp. range - heating: -25~35°C
- Outdoor air temp. range - cooling: -5~43°C
- Outdoor air temp. range - DHW: -25~43°C
Functions
- ? Wireless Wi-Fi operation
- ? Modbus RTU protocol
- ⚡ Additional electric heater
- ♨️♨️ Operation of 2 heating circuits
Energy Storage and Optimization
Hybrid Inverter
10 kW
Supporting 200% oversized PV power, Simple Efficient On&OFF Grid parallel system. Adjustable power in each phase, Support diesel generator control (DI/DO).
Specification
- Max. continuous photovoltaic input power: 20kW
- Max. DC voltage: 1100V
- Nominal voltage: 720V
- MPPT voltage range: 140V-1000V
- Starting voltage: 200V
- Max. short-circuit current per MPPT: 20A
- Backup Nominal AC output power: 9.2kW
- Backup Max. output current: 14.5A
- Nominal output voltage: 400V
Functions
- ⚙️ Intelligent operating modes
- ? LCD display
- ? Maximum 8 modules connection
- ? ON/OFF Grid work
- ? CAN/WiFi/RS485 communication
- ⚖️ Unbalanced Output
Battery Energy Storage Unit
5.1 kWh
CATL LFP Battery, Stable and safe Module, pack, system, triple protection. Modular design, Plug and play, Mobile APP Monitoring.
Specification
- Energy capacity: 5.12 kWh
- Usable volume: 4.6 kWh
- Battery type: LFP (LiFePO4)
- Depth of discharge (DoD): 90%
- Nominal voltage: 51.2V
- Life: 10 000 cycles
- Max. charging/discharging power: 2825W/4096W
- DC circuit breaker: 125A
- Max. charging/discharging current: 50 A/80 A
Functions
- ? BMS in each battery
- ?️ IP65 rated
- ?♨️ Built-in battery heaters Advanced AC/DC
- ⚡?️ Multi AC/DC protection
- ? Detailed monitoring of battery parameters
- ? High performance after a long period of operation
Product Range Overview
Kaisai offers a comprehensive range of solutions, including:
- AIR CONDITIONERS
- HEAT PUMPS
- RECUPERATION UNITS
- ALL-IN-ONE SYSTEMS
The full range of products is available on the Kaisai website.
Contact Details
FOR CONSUMERS:
Interested in purchasing Kaisai products? Check the current list of Distributors at: www.kaisai.com
FOR DISTRIBUTORS AND INSTALLERS:
HEAD OFFICE
101A Ostrobramska St.
04-041 Warsaw
22 517 36 00 | 22 879 99 07
SALES DEPARTMENT
22 465 65 85
export@kaisai.com
KLIMA-THERM GROUP ACADEMY
GDANSK BRANCH
48 Budowlanych St.
80-298 Gdansk
58 768 03 33
WARSAW BRANCH
101A Ostrobramska St.
04-041 Warsaw
22 517 36 00
KATOWICE BRANCH
108 Chorzowska St., Building B
40-101 Katowice
32 209 49 26
Do you want to become a Kaisai Distributor? Write or call us.