Wunda Smart Connection Box: Installation Guide & Technical Specifications

Wunda Smart Connection Box

Welcome to WundaSmart

Introduction

Welcome to your Smart Connection Box. This device is a key component for your smart home heating system.

Key Components:

  • Status Lights
  • Setup Pairing Button [⚙️]
  • Output Test Button
  • 5A Fuse
  • Terminal Blocks
  • Wire Clamping Area
  • Actuator Cable Channel
  • DIN Mounting Rail Clamp
  • Wall Fixing Holes
  • Antenna

For more information and support, please visit: www.wundasmart.com/support

Quick Install Guide

  1. First, ensure your choice of Hub is set up and your App is installed.
  2. Mount the Connection Box near the manifold.
  3. Connect actuators to the terminal blocks.
  4. Connect power, pump, and heating source.
  5. Launch your App, choose Devices, then Add device, and select Smart Connection Box.
  6. Hold the Setup Button [⚙️] and wait until the device shows it has been successfully paired.
  7. Configure your installation in the App.
Diagram Description: A front view of the Wunda Smart Connection Box, a white rectangular device with blue terminal blocks. Key components are labeled with numbers 1 through 10: Status Lights, Setup Pairing Button, Output Test Button, 5A Fuse, Terminal Blocks, Wire Clamping Area, Actuator Cable Channel, DIN Mounting Rail Clamp, Wall Fixing Holes, and Antenna.

Technical Specifications

Specification Value
Dimension 326 x 133 x 32 mm
Weight 490 g
Power Supply 230V~ 50Hz
Mounting DIN rail 35mm
Wiring Fixed wiring only
Fuse 5A
Switch Rating 2(1)A 230V~
Pump circuit load 2(1)A 230V~
Thermoelectric actuator circuit load 12x 230V~ 50Hz/20W max
Ingress Protection IP20
Operating Temperature 0°C to 45°C
Storage Temperature -10°C to 55°C
Ambient Humidity Operating 25% to 90%, Storage 15% to 95% (non-condensing)
Software Class A
Rated Impulse Voltage 2.5kV
Radio SRD Frequency 869.85 MHz
Radio SRD Bandwidth 125 kHz
Radio SRD Maximum Power <5 dBm

Precautions

  1. Installation and connection should be carried out by technical service or authorized and qualified persons according to applicable regulations and standards.
  2. Always disconnect the power supply when connecting or disconnecting the devices powered from the main device.
  3. Before installation, read the terms and conditions of the warranty and these instructions. Improper installation or use contrary to these instructions will void the warranty.
  4. All repairs to the device should be carried out by a competent electrician. Otherwise, it will void the warranty.
  5. This device should not be installed or worked on by minors, people with reduced physical or mental abilities, or with lack of experience or knowledge of the equipment, except if supervision and instruction for the safe use of the equipment is provided in such a manner that all the associated hazards are understood.
  6. If a power cord is damaged, it should be replaced by a qualified person in order to avoid a hazard.
  7. Do not install the device with mechanically damaged casing or damaged/broken cables.
  8. The device must not be exposed to water or excessive humidity resulting in steam condensation (e.g. caused by rapid changes of the ambient temperature).

Wiring Examples

Heating Source - Voltage Free (wiring example)

Diagram Description: This diagram shows a simplified wiring setup for a voltage-free heating source. It illustrates connections for mains input (L, N, 5A Fuse), AC output (LON, LON, COM, NO), and connections for Pump, Boiler, and Actuators. The terminal blocks are labeled with L, N, and specific output designations.

Heating Source - 230V~ Output (wiring example)

Diagram Description: This diagram shows a wiring setup for a 230V~ output heating source. Similar to the voltage-free example, it includes mains input (L, N, 5A Fuse) and AC output (LON, LON, COM, NO), but specifically shows connections for Pump, Boiler, and Actuators with 230V~ output terminals.

App Configuration

If you are wiring your two-port valve or direct feed to trigger the boiler to the connection box, ensure that you select the relay within the app when you are selecting your actuators.

App Screenshot Description: Two mobile app screens are shown, titled "Connection box configuration" for "Smart Connection Box 2.0". Each screen displays a grid of numbered buttons (1-12) and a "Relay" button. In both screenshots, button 8 is highlighted and labeled "Relay". Below this, a "Ll test" section shows similar numbered buttons, with button 8 also selected and labeled "Relay". The options "Cancel" and "Save" are visible at the bottom of each screen.

Installer's Notepad

Use this section to record installation details.

Output no Connected to loop no Room name
1
2
3
4
5
6
7
8
9
10
11
12

This Smart Connection Box is connected to:

[Text area for connection details]

Notes:

[Text area for additional notes]

Compliance and Manufacturer

EU Declaration of Conformity

This device is in compliance with essential requirements and other relevant provisions of the following EU Directives:

  • RED Directive 2014/53/EU
  • ROHS Directive 2011/65/EU

A copy of the EU Declaration of Conformity is available at: wundasmart.com/conformity

CE Mark: ??

WEEE Symbol Explanation

The WEEE symbol [♻️] means that a device must be disposed of separately from general household waste. When a device reaches the end of its lifespan, it must be taken to a designated waste collection point for safe disposal or recycling. This conserves natural resources, protects human health, and helps the environment.

Manufacturer

WundaGroup PLC

Caldicot, NP265AD

United Kingdom

Website: www.wundasmart.com

Models: Smart Connection Box, Connection Box

File Info : application/pdf, 5 Pages, 976.73KB

PDF preview unavailable. Download the PDF instead.

Connection-Box-Insert 13-01-25

References

Adobe PDF library 17.00 Adobe Illustrator(R) 24.0

Related Documents

Preview Wunda Phase 4: Professional Heat Source Connection & Control Setup Guide
Comprehensive guide for professional installers on connecting Wunda underfloor heating manifolds to heat sources and setting up smart controls, including wiring, app configuration, and system start-up.
Preview Wunda Rapid Response Boards & Pipe Installation Guide - Phase 2
Phase 2 installation guide for Wunda Rapid Response® underfloor heating boards and pipe. Covers perimeter strip, board laying, bonding, pipe installation, and floor probe preparation for DIY and professional use.
Preview Wunda Rapid Response Installation Guide: Phase 1 - Floor Preparation
Comprehensive guide for Phase 1 of Wunda Rapid Response underfloor heating system installation, covering DIY and professional floor preparation steps.
Preview Wunda Rapid Response Boards Installation Guide - Phase 2
Detailed instructions for Phase 2 of installing Wunda Rapid Response boards and pipe, covering perimeter strip, dry laying boards, bonding, preparing boards for pipe, laying pipe, and preparing for floor finish.
Preview Wunda Duo Board & Vapour Barrier U04 Installation Guide and Technical Specifications
Comprehensive guide to installing Wunda Duo Board and Vapour Barrier (U04), a HDF free-floating sub-floor system for resilient flooring over underfloor heating. Includes technical specifications and detailed installation steps.
Preview Wunda Spray Adhesive T07: Application, Safety & Technical Guide
Comprehensive guide to Wunda Spray Adhesive T07, covering application techniques, safety precautions, technical specifications, and canister handling for bonding Wunda Rapid Response boards.
Preview Wunda Rapid Response Floor Coverings Installation Guide
A comprehensive guide detailing the installation of various floor coverings, including wood, laminate, carpet, LVT, vinyl, poured finishes, and tile/stone, with Wunda Rapid Response underfloor heating systems. Covers preparation, installation methods, approved compounds, curing times, and floor probe usage.
Preview Wunda Duo Board & Vapour Barrier Installation Guide
Comprehensive guide for installing Wunda Duo Board and Vapour Barrier, a HDF free-floating sub-floor system designed for resilient floorings over underfloor heating.