User Guide for ZKTeco models including: G5 Multi Biometric Access Control Terminal, G5, Multi Biometric Access Control Terminal, Biometric Access Control Terminal, Access Control Terminal, Control Terminal
G5 - ZKTeco Indonesia
3 Terminal Block AUXIN SEN BUT GND NO COM1 NC1 ALARM-ALARM 12V OUT GND 485B 485A 232TXD 232RXD WD0 WD1 IWD0 IWD1 BELL BELL-Auxiliary Input Sensor Exit Button Alarm
File Info : application/pdf, 16 Pages, 4.80MB
DocumentDocumentQUICK START GUIDE Outdoor & Multi-Biometric Access Control Terminal Applicable Model: G5 Version: 1.0 Date: May 2023 Safety Precautions Before installation, please read the following precautions carefully to prevent the risks of danger to the users of this product or those nearby and damaging the device. Do not expose to direct sunlight, water, dust and soot. Do not place any magnetic objects near the product. Magnetic objects such as magnets, CRT, TV, monitors or speakers may damage the device. Do not place the device next to heating equipment. Prevent water, drinks or chemicals leaking into the device. This product is not intended for use by children unless they are supervised. Do not drop or damage the device. Do not disassemble, repair or modify the device. Do not use the device for any purpose other than those specified. Remove dusts or dirts regularly. While cleaning, wipe dust off with a smooth cloth or towel instead of water. Contact your supplier in case of any problem! 1 Device Overview 1.142" (29.0mm) Near-infrared Flash Microphone Near-infrared Camera Visible Light Camera 8" HD Capacitive Touch Screen Built-in ID Card Reader Fingerprint Scanner 11.004" (279.5mm) Terminal Block Back Plate 5.551" (141.0mm) 2 Micro USB USB Port Speaker Terminal Block USB AUXIN SEN BUT GND NO COM1 NC1 ALARMALARM+ 12V OUT GND 485B 485A 232TXD 232RXD WD0 WD1 IWD0 IWD1 BELL+ BELL- Auxiliary Input Sensor Exit Button Lock Alarm Power Out RS485 RS232 Wiegand Out Wiegand In Bell Power In Ethernet 3 Product Installation The recommended distance 61.024" (1.55m) For users whose height is between 55.118" to 70.866" (1.4m to 1.8m), the recommended height of the equipment is 61.024" (1.55m), and the distance from the personnel to the equipment is 19.685" (0.5m). Users not in the range can adjust the position by moving back and forth according to the actual situation. 19.685" (0.5m) Installation on the wall First passing the wires through the wiring hole in the back plate. Drill holes at suitable locations on the wall, then fix the back plate to the wall with mounting screws, the recommended distance from the camera to the ground is 61.024 inches (1.55m). Then attach the device to the back plate from top to bottom. Fasten the device to the back plate with a security screw. 1 2 3 1 2 4 4 Power & Ethernet Connection Power Connection AC Adapter Recommended power supply Recommended AC adapter: 12V, 3A To share the power with other devices, use an AC adapter with higher current ratings. Ethernet Connection Network Cable Router 5 Access Control & Reader Connection Access Control Connection 12V OUT GND 485B 485A 232TXD 232RXD WD0 WD1 IWD0 IWD1 Reader Connection 12V OUT GND 485B 485A 232TXD 232RXD WD0 WD1 IWD0 IWD1 WD0 WD1 GND +12V Access Controller GND Do not use +12V GND 485485+ RS485 Reader +12V GND RXD TXD RS232 Reader +12V GND WD0 WD1 Wiegand Reader Do not use 6 Lock Relay Connection The system supports both Normally Opened Lock and Normally Closed Lock. The NO Lock (Normally Opened when powered) is connected with 'NO' and 'COM' terminals, and the NC Lock (Normally Closed when powered) is connected with 'NC' and 'COM' terminals. The power can be shared with the lock or can be used separately for the lock, as shown in the example with NC Lock below: Device not sharing power with the lock is shown below: AUXIN SEN BUT GND NO COM1 NC1 ALARMALARM+ +12V DC DO NOT REVERSE THE CONNECTION. FR107 V- V+ NC COM NO Magnetic Lock +12V GND AC Adapter DC12V, 3A Do not use Device sharing power with the lock is shown below: AUXIN SEN BUT GND NO COM1 NC1 ALARMALARM+ +12V GND 7 DO NOT REVERSE THE CONNECTION. FR107 V- V+ NC COM NO Magnetic Lock AC Adapter DC12V, 3A Do not use Connecting Other Devices Bell Connection BELL+ BELL- +12V DC Bell Power Door Bell Smoke Detector, Door Sensor, Exit Button & Alarm Connection AUXIN SEN BUT GND NO COM1 NC1 ALARMALARM+ Detector Power NO COM +12V DC Smoke Detector Door Sensor Exit Button Alarm +12V DC Alarm Power Do not use 8 Standalone Installation Option A Option B PC TCP/IP WAN 3G Door Bell Door Sensor PC SWITCH Alarm Lock USB Disk Exit Button Smoke Detector 9 Menu Functions Enroll New User When there is no Super Administrator set in the device, click to enter the menu. Add a new user and set the User Role to Super Admin, then the system will request for Administrator's verification before entering the menu. It is recommended to register a Super Administrator initially for security purposes. Click > User Management > > New User to register a new user. The procedure includes entering the User ID and Name, choosing User Role, registering Fingerprint, enroll Card Number, setting Password and setting Access Control Role. 10 Menu Functions Access Settings Click > Access Control > Access Control Options to enter the setting interface. Network Settings Click > System Settings > Network settings to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the top right corner of the standby interface. 11 Menu Functions Attendance Search View records in the device: Click > Attendance Search > Access Logs (records of all users will be displayed) > select Time Range > press OK, the corresponding attendance logs will be displayed. View records on computer: Click > USB Management > Download to USB. Insert the USB disk correctly and download the data to the USB drive, then copy this data from the USB drive to your PC. The downloaded data filename will be "Device Serial Number.dat", you can open and view it. 12 Menu Functions & Troubleshooting Date and Time Settings Click > System Settings > Date and Time, to enter Date and Time setting interface. Troubleshooting 1. Fingerprint can't be detected or it takes too long. Ø Check whether the finger or fingerprint sensor is stained with sweat, water, or dust. Ø Retry after wiping the finger and fingerprint sensor with dry paper tissue or a mildly wet cloth. Ø If the fingerprint is too dry, blow onto the fingertip and retry. 2. Failed to gain access after successful verification. ØCheck with administrator whether the enrolled fingerprint has been deleted from the device or not. 3. Door doesn't open after successful verification. ØCheck if the lock open duration parameter is set appropriately. 13 Specifications Model CPU Operation System Storage SDK WLAN Display Screen Type Resolution Camera Card Type QR Code (optional) User Capacity Face Templates Capacity Fingerprint Capacity (optional) Card Capacity Record Capacity Firmware Functions Language Software G5 64bit Eight Core Customized Computer Vision CPU Android 9.0 2GB LPDDR3 16GB eMMC Android LCDP, PUSH SDK 2.4GHz/5.0GHz Dual Frequency; IEEE 802.11 a/b/g/n/ac 8 inch TFT LCDColor Screen Capacitive Touch Screen 800*1280 2MP Binocular Camera 125kHz ID card & 13.56MHz IC card Multi-tech Card Module (optional) ISO14443A/B & ISO15693 & HID Prox Dynamic QR codes on the ZKBioSecurity mobile application QR code, PDF417, Data Matrix, MicroPDF417, Aztec scanning in third-party development projects 100,000 100,000 30,000 100,000 5,000,000 Push, Schedule Bell, Automatic Status Switch, Record Query, Access Levels, Groups, Holidays, DST, Duress Mode (Password & Fingerprint), Anti-Passback, Customization of Wallpaper & Screen Saver, Tamper Alarm English, Korean, Latin American, Indonesian, Vietnamese, Traditional Chinese, Portuguese, Spanish, Farsi, Japanese, Russian and Thai BioTime 8.0 , ZKBioSecurityZKBioCV Security 14 ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 - 82109991 Fax : +86 755 - 89602394 www.zkteco.com Copyright © 2023 ZKTECO CO., LTD. All Rights Reserved.