VOLA A62, A63, A63F, VR1795 Fitting Instructions
Product Series: VOLA A62, A63, A63F, VR1795
Product Overview
This document provides fitting instructions and technical specifications for the VOLA A62, A63, A63F, and VR1795 series of plumbing fittings. These products are designed for efficient water drainage in various sanitary applications.
The document is available in multiple languages, including English, German, Danish, Swedish, Dutch, and French, ensuring broad accessibility for installers and users.
Product Dimensions and Specifications
Accurate dimensions are crucial for proper installation. The following specifications are provided for the VOLA A62, A63, A63F, and VR1795 models:
A62 Model Dimensions
The A62 model features the following key dimensions:
- Overall Height: 60 mm (2 3/8")
- Lower Section Height: 28 mm (1")
- Main Diameter: Ø64 mm (2 1/2")
- Secondary Diameter: Ø63 mm (2 1/2")
- Lower Outlet Diameter: Ø43 mm (1 3/4")
- Drain Outlet Diameter: Ø60 mm (2 3/8")
Diagrams illustrate these dimensions for the A62 fitting.
A63 and A63F Model Dimensions
The A63 and A63F models share similar dimensions to the A62, with specific variations:
- Main Diameter: Ø64 mm (2 1/2")
- Secondary Diameter: Ø63 mm (2 1/2")
- Lower Outlet Diameter: Ø43 mm (1 3/4")
- Drain Outlet Diameter: Ø60 mm (2 3/8")
- A63F specific dimension: 9 mm (3/8")
Diagrams show these dimensions for the A63 and A63F fittings.
VR1795 Model Specifications
The VR1795 component is designed for installation with a thickness range of 10-25 mm (3/8" - 1"). It can also accommodate thicknesses from 35-50 mm (1 1/2" - 2") when used with appropriate parts.
Diagrams show the VR1795 component and its dimensions.
Installation Thickness Range
The fittings are designed for installation in surfaces with thicknesses typically ranging from 35 mm to 50 mm (1 1/2" to 2"). The VR1795 component can adapt to thinner surfaces.
Diagrams illustrate installation into surfaces of varying thicknesses.
Assembly Instructions
Follow these steps for proper installation of the VOLA drain fittings:
Step 1: Preparation
Apply plumbers putty or installation sealant (e.g., Sanitetskit, loodgieters mastiek, Mastic sanitaire) around the underside of the fitting where it will meet the surface of the sink or countertop. This ensures a watertight seal.
Diagram shows a tub of plumbers putty/sealant.
Step 2: Installation
Insert the fitting through the prepared opening in the sink or countertop. Ensure correct orientation. For the A63F model, specific handling may be required, as indicated by the note 'Not/Nicht/Ikke/Inte/Niet/Pas: A63F'. Press down firmly to seat the fitting.
The diagram shows a 'PUSH' indicator, signifying the action required to properly install or engage the fitting.
Diagram illustrates the fitting being installed into a sink surface, with a 'PUSH' indicator.
Step 3: Sealing and Functionality Check
Once installed, the fitting should create a watertight seal. The diagrams illustrate the fitting submerged in water to demonstrate functionality and sealing. Ensure the 'PUSH' mechanism operates correctly and the seal is maintained.
Important: A red cross symbol (❌) in the diagrams indicates an incorrect installation, configuration, or potential issue.
Diagram shows the installed fitting in water, demonstrating sealing. Another diagram shows an incorrect installation marked with a red cross (❌).
Parts Identification
The following components are identified in the diagrams for the VOLA A62, A63, A63F, and VR1795 series:
Main Fittings and Components
- Model A62 Main Body: Part 1814
- Model A63 Main Body: Part 1814A
- Top Cap/Stopper: Part 1788 (for A62, A63), Part 1788F (for A63F)
- Stem/Body Components: Part 1796A
- Lower Body/Threaded Section: Parts 1799, 1799A, 1799B
An exploded view diagram shows these main components.
Accessories and Optional Parts
- Distance Collar: Parts 1793, 1795, 1794. These parts have dimensions including Ø60 mm diameter and 26 mm height, with an outer diameter of Ø43 mm.
- Note: The Distance Collar (components 1793, 1795, 1794) is explicitly stated as 'Not included in the delivery' in multiple languages.
- Combined part references for installation: 1795 + A63, 1795 + A62.
Diagram shows the Distance Collar components and their dimensions.
Contact and Manufacturer Information
For further product information, support, or to view the full range of VOLA products, please visit the official website:
Manufacturer: VOLA A/S
Address: Lunavej 2, DK-8700 Horsens, Denmark
Telephone: +45 7023 5500
Email: sales@vola.com