Commercial Pressure Switches

Types F and G

Class 9013

Product Descriptions

The Class 9013 Type F line of pressure switches are UL Listed and CSA Certified as commercial control equipment. The Class 9013 Type G line of pressure switches are UL Listed and CSA Certified as commercial/light industrial control equipment.

Type FHG - PUMPTROL® Compressor Pressure Switch

The Type FHG - PUMPTROL® Compressor Pressure Switch is used to control electrically driven air compressors. It is diaphragm actuated and has contacts that open on rising pressure.

[Image: A grey, rectangular pressure switch with a diaphragm housing and electrical conduit connections.]

Type FSG, FYG, FRG - PUMPTROL® Water Pump Pressure Switches

The Type FSG, FYG, FRG - PUMPTROL® Water Pump Pressure Switches are used to control electrically driven water pumps and have the following features:

  • The Type FSG is the standard water pump switch, suitable for all types of pumps: jets, submersible, reciprocating, etc.
  • The Type FYG is designed to meet higher horsepower and pressure requirements.
  • The Type FRG is reverse acting: the contacts open on falling pressure.
  • All are diaphragm actuated.

[Image: A grey, square-ish pressure switch with a clear cover showing internal components and conduit connections.]

Type G - PUMPTROL® Commercial/Light Industrial Pressure Switch

The Type G - PUMPTROL® Commercial/Light Industrial Pressure Switch is used to control electrically driven water pumps and air compressors. It has higher electrical ratings for direct control of motors in pump and compressor applications. The Type G switch is diaphragm actuated and has contacts that open on rising pressure.

[Image: A grey, box-like pressure switch with a diaphragm housing and conduit connections, shown with an optional release valve.]

Technical Overview

Operating Points (Settings)

Every pressure switch has two operating points: one on rising pressure and one on falling pressure. The operating point on rising pressure is referred to as the TRIP POINT or cut-out for pumps and compressors, and the operating point on falling pressure is referred to as the RESET POINT or cut-in for pumps and compressors. These operating points are called the SETTINGS of the switch.

  • TRIP POINT (rising pressure)
  • RESET POINT (falling pressure)

Differential

The differential is the difference in pressure between the trip point (cut-out) and the reset point (cut-in). It can be adjustable or nonadjustable (fixed). Example:

Cut-in: 30 psi
Cut-out: 50 psi
Differential: 20 psi (50-30 psi)

Range

The range is the pressure limits within which the operating points (settings) can be adjusted. The range of the Class 9013 pressure switch is referenced to the operating point on rising pressure (trip point). The differential subtracts from the trip point setting.

During the normal operating cycle, system pressure should never exceed the upper limit of the range when using a diaphragm actuated switch. This will greatly reduce the life of the diaphragm.

Maximum Allowable Pressure

Maximum allowable pressure is the pressure to which a switch can be subjected without causing a change in operating characteristics, shift in settings, or damage to the device.

Pressure surges may occur in a system during the start-up of a machine or from valve operation. Surges are not normally detrimental to the life of a switch if the surge is within the maximum allowable pressure rating of the switch. Diaphragm actuated switches should not be subjected to more than 10 surges per day. More frequent surges will greatly reduce the life of the diaphragm.

Specifications

Electrical Ratings

Switch TypeVoltageSingle Phase AC (Hp)Polyphase AC (Hp)DC (Hp)Control Circuit Rating
FHG2, 3, 4, 9, 12
13, 14, 19, 42, 44, 49
115
230
460/575
1 1/2
2
1
2
3
1
1/4
1/4
--
A600
FHG22, 24, 29, 32, 33
34, 39, 52, 54, 59
FYG, FYW
115
230
460/575
2
3
1
3
5
1
1/2
1/2
--
FRG One Pole
All Form H
115
230
1
1
1/4
1/4
--
--
A300
FRG Two Pole115
230
1
1
1
1
1/4
1/4
All 9013G Form H115
230
460/575
1
2
2
1/2
1/2
1
--
--
--
A600
All 9013G Except Form H115
230
460/575
2
3
5
1
1
5
--
--
--

Note: DC Rating does not apply to Form M4. 600 volt DC rating does not apply. See 1993 NEC Article 430-84.

Temperature Ratings

MinimumMaximum
Media-22 °F (-30 °C)+257 °F (+125 °C)
Ambient-22 °F (-30 °C)+158 °F (+70 °C)

Note: FSG and FYG have a 32 °F (0 °C) minimum ambient temperature rating.

Maximum Allowable Pressure

TypePressure (psig)
FHG, FSG, FYG, FSW, FYW220
FRG, GHB, GHG, GSB, GSG300
GMG, GSR, GSW100
GHR, GHW250

Certifications

Type FHG - PUMPTROL® Compressor Pressure Switch: UL Listed (File E12158 CCN NKPZ), CSA Certified (File LR 25490 Class 3211 06).

Type FSG, FYG, FRG - PUMPTROL® Water Pump Pressure Switch: UL Listed (File E12158 CCN NKPZ), CSA Certified (File LR 25490 Class 3211 06).

Type G - PUMPTROL® Commercial/Light Industrial Pressure Switch: UL Listed (File E12158 CCN NKPZ, Except GHR and GSR), CSA Certified (File LR 25490 Class 3211 06, Except GHR and GSR). Also UL Listed (File E12443 CCN NOWT, For GHR and GSR), CSA Certified (File LR 26817 Class 3218 05, For GHR and GSR).

Dimensions

Type F - PUMPTROL® Compressor and Water Pump Pressure Switch Dimensions

[Diagram showing dimensions for Type F switches. Key measurements include overall height, width, depth, port size, and hex size. A table lists specific switch types and their 'A' dimension.]

Type F Dimensions:

  • Overall Height: 3.76 in (96 mm)
  • Width: 2.78 in (71 mm)
  • Depth: 2.34 in (59 mm)
  • Port Size: 1/2-14 STRAIGHT PIPE THREAD
  • Hex Size: 15/16
Switch TypeInchesA Dimension (mm)
FSG1, FYG11 1/3226
FHG2, 12, 22, 32, 42, 52, FRG2, FSG2, FYG229/3223
FHG3, 13, 33, FRG3, FSG3, FYG31 9/3233
FHG9, 19, 29, 39, 49, 59, FSG9, FYG91 3/3228

Type G - PUMPTROL® Commercial/Light Industrial Pressure Switch Dimensions

[Diagrams showing dimensions for Type G switches, including different enclosure types and mounting brackets. Key measurements include overall height, width, depth, port sizes, and hole dimensions. Tables list specific switch types and their dimensions.]

Type G Dimensions (Example for GHG, GSG):

  • Overall Height: 6.17 in (157 mm)
  • Width: 3.85 in (98 mm)
  • Depth: 2.50 in (64 mm)
  • Main Port Thread: 1/4-18 NPSF Pipe Thread
  • Mounting Bracket: Shown is available as a Class 9049 Type A-52 Kit.
  • Net Weight: 2 1/4 Pounds

[Diagram for Type GMG showing similar dimensions and mounting bracket details.]

Selection and Modifications

Type FHG – Selection and Modifications

Type FHG PUMPTROL® Compressor Pressure Switches

Adjustable Cut-Out Range Increasing Pressure (PSIG)Approximate Differential (PSIG)Non-Adjustable (PSIG)PolesPressure ConnectionLower HP NEMA Type 1 Enclosure TypeHigher HP NEMA Type 1 Enclosure Type
40-1002021/4" NPSF (Internal)
3/8" NPSF (Internal)
1/4" Four Way
1/4" NPT (External)
FHG2
FHG3
FHG4
FHG9
FHG22
FHG33
FHG24
FHG29
70-1503021/4" NPSF (Internal)
3/8" NPSF (Internal)
1/4" Four Way
1/4" NPT (External)
FHG12
FHG13
FHG14
FHG19
FHG32
FHG33
FHG34
FHG39
100-2004021/4" NPSF (Internal)
1/4" Four Way
1/4" NPT (External)
FHG42
FHG44
FHG49
FHG52
FHG54
FHG59

Pressure Code (fixed differential)

Below is the pressure code table for fixed differential action devices. Existence of a code does not imply that the code is available for any or all devices.

SettingsCode
Off at 100 PSIJ27
Off at 110 PSIJ37
Off at 115 PSIJ38
Off at 120 PSIJ69
Off at 125 PSIJ52
Off at 135 PSIJ39
Off at 140 PSIJ68
Off at 150 PSIJ55
Off at 155 PSIJ40
Off at 175 PSIJ59
Specify other pressureJ99

Special Features And Modifications For Type FHG

DescriptionForm Letter
Standard Pack of 20 SwitchesC2O
Addition of a Second Ground ScrewG4★
Maintained Manual Cut-Out Lever (AUTO-OFF)M1
Pulsation PlugP
1/2" Conduit Bushing - 1/2" Long Thread - On LeftT
1/2" Conduit Bushing - 1/2" Long Thread - on RightT1
Slip-On Connectors (Load Side Terminals Only)U
Slip-On Connectors (Line and Load Terminals)U2
Factory Sealed Range StudW
Two-Way Pressure Release ValveX
Quick Connect Two-Way Pressure Release Valve (for use with Polyflow Tubing)X1
Black CoverZ22

★ Can be field installed. Nameplate should then be marked with the Form letter and maintenance and ordering records corrected.

Ordering Information (Type FHG)

  1. Specify Class 9013 Type FHG.
  2. Select pressure code from Pressure Code Table and add code designation to end of type number. Be sure that pressure code falls within the limits of the device as shown in the device listings.
  3. If special features are desired, add the appropriate Form letter to the Class and Type. Arrange Form letters in alphabetical sequence when ordering more than one special feature.
  4. Place packaging code at end of sequence with other forms when ordering.

For standard pack of 20 devices per box: C20
For individual packaged devices: leave blank

Example: 9013FHG19J52MIXC20

NOTE: If no packaging code is indicated, devices will be shipped individually packaged.

Types FSG, FYG PUMPTROL® Water Pump Pressure Switches – Selection and Modifications

Standard Action: Contacts Open On Rising Pressure

Cut-Out Range (PSIG)Approximate Adjustable Differential (PSIG)Cut-in Range (PSIG)Pressure Connection2 Pole NEMA Type 12 Pole NEMA Type 3R
20-6515-305-451/8" NPSF Internal
1/4" NPSF Internal
1/4" NPT External
1/4" Bayonet (barbed)
90° Elbow 1/4" Bayonet
FSG1
FSG2
FSG9
FSG10
FSG20
FSW1
FSW2
FSW9
FSW10
FSW20
20-5010-3010-301/4" NPSF Internal
1/4" NPT External
FSG22
FSG29
FSW22
FSW29
9-306-203-101/4" NPSF Internal
1/4" NPT External
FSG42
FSG49
FSW42
FSW49
34-6515-3019-451/8" NPSF Internal
1/4" NPSF Internal
1/4" NPT External
1/4" Bayonet (barbed)
90° Elbow 1/4" Bayonet
FYG1
FYG2
FYG9
FYG10
FYG20
FYW1
FYW2
FYW9
FYW10
FYW20
25-8020-305-601/4" NPSF Internal
1/4" NPT External
FYG22
FYG29
FYW22
FYW29
9-406-203-101/4" NPSF Internal
1/4" NPT External
FYG42
FYG49
FYW42
FYW49

Note: Must be mounted in vertical position to maintain enclosure rating.

Pressure Codes (Standard action)

Below is the pressure code table for standard action devices. Existence of a code does not imply that the code is available for any or all devices.

SettingsCode
5-21 PSIJ15
8-20 PSIJ16
20-40 PSIJ20
20-50 PSIJ18
30-50 PSIJ21
40-60 PSIJ24
50-70 PSIJ33
55-85 PSIJ34
60-80 PSIJ25
Specify other pressureJ99

Special Features And Modifications For Type FSG, FYG & FRG Devices

DescriptionApplies toForm Letter
Standard Pack of 20 Devices per boxAll Type FC2O
Pilot Light - Indicates Switch Contacts ClosedFSG, FYGG5★
One Normally Open-One Normally Closed ContactFRG 2 Pole OnlyH
Maintained Manual Cut-Out Lever (AUTO-OFF)FSG, FYGM1
Momentary Manual Cut-In Lever (AUTO-START)FRG2-59 OnlyM3
Low Pressure Cut-Off (AUTO-START-OFF) Operates at Approximately 10 PSIG Below Cut-in and will turn off the pumpFSG, FYG (Types 1-20 only)M4
Maintained Manual Cut-in Lever (AUTO-ON)FRG2-59 OnlyM5
Pulsation Plug (Standard on FSG-4 and FYG-4)FRG, FSG, FYGP
Salt Water Flange (1/4 NPSF Internal Only)All Type FQ
Plastic Flange (max. temp. 120°F) (max. pressure 80 psi)FRG, FSG, FYGQ8
1/2" Conduit Bushing - 1/2" Long Thread - on Left1/4" NPSF Internal OnlyT
1/2" Conduit Bushing - 1/2" Long Thread - on RightAll Type FT1
Slip-On Connectors (Load Side Terminals Only)FSG, FYGU
Slip-On Connectors (Line and Load Terminals)FSG, FYGU2
Black CoverFSG, FYGZ22

★ Can be field installed. Nameplate should then be marked with the Form letter and maintenance and ordering records corrected. f Nylon pulsation plug can be field installed on types having 1/4" NPSF Internal connector. Part number 1530-S6-G1 is one bag of 50 plugs.

Ordering Information (Type FSG, FYG)

  1. Specify Class 9013 Type FSG, FYG, or FYG.
  2. Select pressure code from Pressure Code Table and add code designation to end of type number. Be sure that pressure code falls within the limits of the device as shown in the device listings.
  3. If special features are desired, add the appropriate Form letter to the Class and Type. Arrange Form letters in alphabetical sequence when ordering more than one special feature.
  4. Place packaging code at end of sequence with other forms when ordering.

For standard pack of 20 devices per box: C20
For individual packaged devices: leave blank

Example: 9013FSG2J21MPU2C20

NOTE: If no packaging code is indicated, devices will be shipped individually packaged.

Type FRG PUMPTROL® Water Pump Pressure Switches – Selection and Modifications

Reverse Action: Contacts Open On Falling Pressure

Cut-in Range (PSIG)Approximate Adjustable Differential (PSIG)Cut-Out Range (PSIG)Pressure Connection1 Pole Type2 Pole Type
23-6515-308-451/4" NPSF Internal
3/8" NPSF Internal
1/4" Flare
1/4" NPT External
FRG12
FRG13
FRG18
FRG19
FRG2
FRG3
FRG8
FRG9
10-456-204-251/4" NPSF Internal
3/8" NPSF Internal
1/4" Flare
1/4" NPT External
FRG32
FRG33
FRG38
FRG39
FRG22
FRG23
FRG28
FRG29
6-145 Non-Adjustable1-111/4" NPSF Internal
3/8" NPSF Internal
1/4" Flare
1/4" NPT External
FRG52
FRG53
FRG58
FRG59
FRG42
FRG43
FRG48
FRG49
40-10020-3020-751/4" NPSF Internal
3/8" NPSF Internal
1/4" Flare
1/4" NPT External
FRG72
FRG73
FRG78
FRG79
FRG62
FRG63
FRG68
FRG69
65-15030-4535-1201/4" NPSF Internal
3/8" NPSF Internal
1/4" Flare
1/4" NPT External
FRG92
FRG93
FRG98
FRG99
FRG82
FRG83
FRG88
FRG89

Pressure Codes (Reverse action)

Below is the pressure code table for reverse action devices. Existence of a code does not imply that the code is available for any or all devices.

SettingsCode
8.5-5.5 PSIJ17
10-5 PSIJ36
22-12 PSIJ22
22-16 PSIJ19
35-20 PSIJ70
40-20 PSIJ23
50-30 PSIJ35
80-60 PSIJ32
100-80 PSIJ51
150-120 PSIJ64
Specify other pressureJ99

Special Features And Modifications For Type FSG, FYG & FRG Devices

(Table already included in FSG/FYG section, as it applies to all three)

Ordering Information (Type FRG)

(Ordering information is similar to FSG/FYG, but specific examples might differ. The general structure is the same.)

  1. Specify Class 9013 Type FRG.
  2. Select pressure code from Pressure Code Table and add code designation to end of type number. Be sure that pressure code falls within the limits of the device as shown in the device listings.
  3. If special features are desired, add the appropriate Form letter to the Class and Type. Arrange Form letters in alphabetical sequence when ordering more than one special feature.
  4. Place packaging code at end of sequence with other forms when ordering.

For standard pack of 20 devices per box: C20
For individual packaged devices: leave blank

NOTE: If no packaging code is indicated, devices will be shipped individually packaged.

Type G PUMPTROL® Commercial/Light Industrial Pressure Switch – Selection and Modifications

Cut-Out Range (PSIG)Approximate Adjustable Differential (PSIG)Cut-In Range (PSIG)EnclosurePolesNPSF Internal Pressure ConnectionType
10-354-85½-30½NEMA Type 1 General Purpose21/4GMG2
20-8015-305-60NEMA Type 3R
Rainproof
21/4GSB2
NEMA Type 1 General Purpose21/8
1/4
3/8
GSG1
GSG2
GSG3
20-8020-405-50NEMA Type 7 & 9 Hazardous Locations21/8
1/4
3/8
GSR1
GSR2
GSR3
NEMA Type 4 Watertight21/8
1/4
3/8
GSW1
GSW2
GSW3
65-20020-4040-170NEMA Type 3R
Rainproof
21/4GHB2
NEMA Type 1 General Purpose21/8
1/4
3/8
GHG1
GHG2
GHG3
65-20020-4040-170NEMA Type 7 & 9 Hazardous Locations21/8
1/4
3/8
GHR1
GHR2
GHR3
NEMA Type 4 Watertight21/8
1/4
3/8
GHW1
GHW2
GHW3
80-25025-4532-215NEMA Type 3R
Rainproof
21/4GHB5
NEMA Type 1 General Purpose21/8
1/4
3/8
GHG4
GHG5
GHG6
80-25024-4532-215NEMA Type 7 & 9 Hazardous Locations21/8
1/4
3/8
GHR4
GHR5
GHR6
NEMA Type 4 Watertight21/8
1/4
3/8
GHW4
GHW5
GHW6
80-25040-6030-190NEMA Type 7 & 9 Hazardous Locations21/8
1/4
3/8
GHR4
GHR5
GHR6
NEMA Type 4 Watertight21/8
1/4
3/8
GHW4
GHW5
GHW6

Note: Must be mounted in vertical position to maintain enclosure rating.

Pressure Code Table (Type G)

Pressure Setting (Close-Open)

CodeSettings
J2020-40 PSI
J2130-50 PSI
J2340-20 PSI
J2440-60 PSI
J2560-80 PSI
J2670-90 PSI
J2870-100 PSI
J2975-100 PSI
J3080-100 PSI
J3190-120 PSI
J51100-80 PSI
J53100-125 PSI
J54110-125 PSI
J56110-150 PSI
J57120-150 PSI
J58125-150 PSI
J60125-175 PSI
J61130-175 PSI
J62140-175 PSI
J63145-175 PSI
J64150-120 PSI
J65215-250 PSI
J66140-170 PSI
J67150-175 PSI
J99Specify Setting Required

Special Features And Modifications For Type G Devices

DescriptionApplies toForm Letter
Standard Pack of 10 Devices per boxAll Type GC1O
3-Way Lever (On-Auto-Off) (Not compatible with Form X)GHG, GMG, GSGE
One Normally Open-One Normally Closed ContactAll Type GH
Pulsation PlugAll Type GP
Reverse ActionAll Type GR
Slip-On Connectors (Load Side Terminals Only)All Type GU
Slip-On Connectors (Line and Load Terminals)All Type GU2
Two-way Pressure Release Valve (Not compatible with Form E)GHB, GMG, GSB, GHG, GSGX
GHR, GHW, GSR, GSWX
1/4" Male Pipe Thread on Pressure ConnectionAll Type GZ
1/2"-14 NPT ExternalAll Type GZ16
1/4"-18 NPT InternalAll Type GZ23
3/8" Male Pipe Thread on Pressure ConnectionAll Type GZ23

Ordering Information (Type G)

  1. Specify Class 9013 Type G.
  2. Select pressure code from Pressure Code Table and add code designation to end of type number. Be sure that pressure code falls within the limits of the device as shown in the device listings below.
  3. If special features are desired, add the appropriate Form letter to the Class and Type. Arrange Form letters in alphabetical sequence when ordering more than one special feature.
  4. Place packaging code at end of sequence with other forms when ordering.

For standard pack of 10 devices per box: C10 (Available on GHB, GHG, GSB, and GSG)
For individual packaged devices: leave blank

NOTE: If no packaging code is indicated, devices will be shipped individually packaged.

Company Information

Square D Company
8001 Highway 64 East
Knightdale, NC 27545-9023, USA
(919) 266-3671
www.squared.com

Square D and [Square D logo symbol] are registered trademarks of Square D Company.
PUMPTROL® is a registered trademark of Square D Company.
SP is a registered trademark of the Canadian Standard Association.
UL is a registered trademark of Underwriters Laboratory.

Catalog No. 9013CT9701R8/98 September 1998 © 1998 Square D All Rights Reserved.
Replaces 9013CT9701 dated 6/98.

PDF preview unavailable. Download the PDF instead.

9013-FSG-2 Acrobat Distiller 3.0 for Power Macintosh

Related Documents

Preview Square D Pumptrol 9013FS Water Pump Switch Data Sheet
Detailed product data sheet for the Square D Pumptrol 9013FS water pump switch, including specifications, dimensions, environmental ratings, and ordering information. Features adjustable differential and 30-50 PSI range.
Preview Square D Manual Starters and Switches Selection Guide
Comprehensive selection guide for Square D manual starters and switches, covering Type F, K, M, T, and Class 2601 drum switches. Includes specifications, applications, enclosures, and dimensions for industrial motor control.
Preview Square D Class 8110 High Voltage Contactor Service Bulletin & Manual
This service bulletin from Square D provides detailed information on the Class 8110 High Voltage Drawout Contactor, Type E, Series A, including general description, inspection, installation, maintenance, and troubleshooting procedures.
Preview Square D SDSA 3-Phase Surge Protective Devices (SPDs)
Comprehensive information on Square D Surgelogic SDSA 3-Phase Surge Protective Devices (SPDs), covering Type 1 protection for Wye and Delta configurations, features, performance specifications, installation guidelines, warranty details, and model selection.
Preview Square D Sepam Digital Relays: Product Line Overview
An overview of the Square D Sepam series of digital protective relays from Schneider Electric, detailing their features, applications, and selection criteria for various power system needs.
Preview SQUARE D NEMA Size 0 & 1 Starters with Melting Alloy Overload Relay (MO558M) - Technical Specification
Detailed technical specifications and wiring guidance for SQUARE D NEMA Size 0 & 1 Starters, Class 8536, Type S, featuring Melting Alloy Overload Relays (MO558M). Includes control and power wiring diagrams, safety warnings, and thermal unit selection tables.
Preview Square D 2008 Pocket Digest: Electrical Product Information
Explore the 2008 Square D Pocket Digest for comprehensive information on Schneider Electric's best-selling electrical products. This guide includes catalog numbers, product specifications, and selection guidance for load centers, circuit breakers, and more.
Preview Z-Wave Plus Plug-in: Protocol Implementation Conformance Statement
This document provides the Z-Wave Protocol Implementation Conformance Statement for the Z-Wave Plus Plug-in, detailing its technical specifications, product information, and supported command classes.