Friedrich Kühl Room Air Conditioners
Specifications, Installation and Sizing Guide
Kühl Series: The smartest window air conditioners ever designed.
Friedrich Kühl Room Air Conditioners offer advanced features for optimal comfort and energy efficiency. The Kühl Series is designed for superior performance and ease of use.
Key Features:
- Two, 7-day energy management programs
- Customizable, 7-day schedules (requires KWIFI accessory, sold separately)
- 24-hour timer
- 4 cooling/4 fan-only speeds on select models
- Auto fan
- Auto-changeover between cooling and heating modes (Kühl+ models except EQ08)
- Auto restart
- 8-way air flow control
- Control panel lockout (ON/OFF)
- Steel inner wall and extra dense insulation materials block outdoor noise
- Vibration-isolating design and components reduce operating noise
- Fresh air intake/stale air exhaust vent*
- Washable, antimicrobial air filter
- Check filter reminder
- Optional carbon filter absorbs odors
- Easy filter access
- Robust 20 gauge steel cabinet
- Solid-steel blower housing
- Totally-enclosed commercial grade fan motor
- Durable base pan and steel inner walls
- Aluminum end plates resist rust
- Install in a window or thru-the-wall
- Slideout chassis
- Includes heavy duty window installation hardware (optional accessory on Kühl+ models, sold separately)
- Rugged hardboard side panels (heavy duty side curtains on SQ and EQ models)
- Power cord can run either left or right
- Patented firm grip handles for easier chassis install/removal
- Smart Grid capable
- ENERGY STAR® qualified models
- EntryGard™ anti-intrusion protection secures the chassis to the sleeve to deter ‘kick-in’ intrusion
- Insect barrier*
- Aluminum rear grille protects the outdoor coil from debris and vandalism
* Option not available on SQ and EQ models
Model Specifications and Sizing
Sleeve Dimensions:
The following table details the dimensions for Kühl sleeves (Q, S, M, L) used for installation:
Sleeve | Sleeve Height (Inches) | Width (Inches) | Depth with Front (Inches) | Shell Depth to Louvers (Inches) | Minimum Extension Into Room* (Inches) | Minimum Extension Outside* (Inches) | Window Width INCHES (Minimum** Maximum) | In-wall Installation Finished Hole (Height Width) | Carton Dimensions (Inches Height Width Depth) |
---|---|---|---|---|---|---|---|---|---|
Q | 14 ¼" | 19 ¾" | 21 3/8" | 8 ½" | 5 ½" | 10 ¾" | 22" 42" | 14 ½" 20" | 8 ½" 18 3/4" 22" |
S | 15 15/16" | 25 15/16" | 29" | 8 ¾" | 5 ¾" | 16 15/16" | 27 3/8" 42" | 16 3/16" 26 3/16" | 7 3/8" 19" 29" |
M | 17 15/16" | 25 15/16" | 29" | 8 ¾" | 5 ¾" | 16 15/16" | 27 3/8" 42" | 18 3/16" 26 3/16" | 7 3/8" 21" 29" |
L | 20 3/16" | 28" | 35 ½" | 16 ½" | 5 3/8" | 18 15/16" | 29 7/8" 42" | 20 3/8" 28 ¼" | 15 1/8" 24 1/2" 31 5/8" |
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
NOTE: S,M and L sleeves may be installed in window with no side kits if properly installed.
Model Specifications Table:
The following table lists detailed specifications for various Kühl models, including cooling and heating capacities, electrical requirements, and energy efficiency ratings.
Model | UPC | Cooling Btu | Heating Btu | Volts | Cooling Amps | Cooling Watts | Heating Amps | Heating Watts | EER | CEER | Estimated Yearly Energy Cost | COP | Moisture Removal (Pints/HR) | CFM | Net Wt. (lbs.) | Ship Wt. (lbs.) | Sleeve |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Kühl® (Cool Only) | |||||||||||||||||
SQ06N10C | 724587432664 | 5800 | — | 115 | 4.1 | 472 | — | — | 12.3 | 12.1 | $43 | — | 1.5 | 190 | 72 | 85 | Q |
SQ08N10D | 724587432671 | 8000 | — | 115 | 6.1 | 656 | — | — | 12.2 | 12.0 | $59 | — | 1.9 | 200 | 72 | 85 | S |
SS08N10C | 724587432589 | 8000 | — | 115 | 5.8 | 656 | — | — | 12.2 | 12.0 | $59 | — | 1.9 | 255 | 99 | 121 | S |
SS10N10C | 724587432640 | 10000 | — | 115 | 7.2 | 820 | — | — | 12.2 | 12.0 | $74 | — | 2.5 | 300 | 106 | 128 | S |
SS12N10C | 724587432688 | 11900 | — | 115 | 8.7 | 975 | — | — | 12.2 | 12.0 | $88 | — | 3.9 | 300 | 112 | 134 | M |
SS12N30C | 724587432695 | 12000/11800 | — | 230/208 | 4.5/4.9 | 984/967 | — | — | 12.2/12.2 | 12.0/12.0 | $89 | — | 3.6 | 300 | 112 | 134 | M |
SS14N10C | 724587432701 | 13600 | — | 115 | 10.4 | 1214 | — | — | 11.2 | 10.9 | $109 | — | 4.3 | 275 | 116 | 138 | M |
SM14N10 | 724587432442 | 13700 | — | 115 | 9.9 | 1123 | — | — | 12.2 | 12.0 | $101 | — | 3.0 | 360 | 141 | 154 | M |
SM14N30 | 724587432435 | 13800/13300 | — | 230/208 | 5.0/5.3 | 1131/1099 | — | — | 12.2/12.1 | 12.0/12.0 | $102 | — | 3.6 | 360 | 141 | 154 | M |
SM18N30B | 724587432718 | 20000/20000 | — | 230/208 | 9.3/10.2 | 2092/2041 | — | — | 9.8/9.8 | 9.8/9.8 | $184 | — | 6.0 | 425 | 191 | 212 | L |
SM21N30D | 724587432725 | 20500/20000 | — | 230/208 | 9.3/10.2 | 2092/2041 | — | — | 9.8/9.8 | 9.8/9.8 | $188 | — | 6.0 | 425 | 193 | 214 | L |
SL24N30C | 724587432626 | 24000/24000 | — | 230/208 | 10.2/11.1 | 2308/2308 | — | — | 10.4/10.4 | 10.3/10.3 | $208 | — | 7.0 | 640 | 212 | 248 | L |
SL28N30C | 724587432657 | 28000/28000 | — | 230/208 | 13.1/14.1 | 2800/2800 | — | — | 10.0/10.0 | 9.9/9.9 | $252 | — | 8.5 | 640 | 109 | 131 | L |
SL36N30B | 724587429961 | 36000/35500 | — | 230/208 | 17.5/19.2 | 4000/3944 | — | — | 9.0/9.0 | 9.0/9.0 | $360 | — | 12.0 | 725 | 132 | 153 | L |
Kühl® + (Heat Pump) | |||||||||||||||||
YS10N10C* | 724587432541 | 10000 | 8800 | 115 | 7.9 | 917 | 9.0 | 978 | 10.9 | 10.8 | $83 | 2.6 | 2.0 | 300 | 113 | 128 | S |
YS12N33C | 724587432558 | 12000/12000 | 11300/11000 | 230/208 | 4.9/5.2 | 1101/1101 | 5.6/5.9 | 1257/1213 | 10.9/10.9 | 10.8/10.8 | $99 | 2.6/2.7 | 3.0 | 375 | 141 | 154 | M |
YM18N34C | 724587432732 | 17500/17200 | 15200/15200 | 230/208 | 7.1/7.6 | 1606/1578 | 19.5/17.0 | 1665/1665 | 10.9/10.9 | 10.8/10.8 | $144 | 2.7/2.7 | 5.4 | 370 | 197 | 211 | L |
YL24N35C | 724587432633 | 24000/24000 | 22000/22000 | 230/208 | 10.1/11.0 | 2330/2330 | 10.7/11.4 | 2391/2391 | 10.3/10.3 | 10.2/10.2 | $210 | 2.6/2.6 | 7.0 | 600 | 213 | 246 | L |
Kühl® + (Electric Heat) | |||||||||||||||||
EQ08N11D | 724587432749 | 8000 | 4000 | 115 | 6.1 | 656 | 11.2 | 1290 | 12.2 | 12.0 | $61 | — | 1.9 | 200 | 72 | 85 | Q |
ES12N33B | 724587430004 | 12000/12000 | 10700/8900 | 230/208 | 4.9/5.2 | 1062/1062 | 16.0/14.7 | 3500/2900 | 11.3/11.3 | 11.2/11.2 | $96 | — | 3.4 | 325 | 115 | 136 | S |
ES14N33 | 724587432466 | 13100/13000 | 10700/8900 | 230/208 | 5.2/5.6 | 1180/1171 | 16.0/14.7 | 3500/2900 | 11.1/10.9 | 10.9/10.9 | $106 | — | 4.0 | 325 | 141 | 154 | M |
EM18N34A | 724587432091 | 20000/20000 | 13000/10600 | 230/208 | 9.3/10.2 | 2041/2041 | 19.5/17.0 | 4200/3500 | 9.8/9.8 | 9.8/9.8 | $184 | — | 6.0 | 425 | 197 | 211 | L |
EM21N34 | 724587432459 | 20500/20000 | 13000/10600 | 230/208 | 9.3/10.2 | 2092/2041 | 19.5/17.0 | 4200/3500 | 9.8/9.8 | 9.8/9.8 | $188 | — | 6.0 | 425 | 212 | 248 | L |
EL24N35 | 724587431612 | 23500/23200 | 17300/14300 | 230/208 | 11.2/12.0 | 2500/2468 | 24.0/22.4 | 5500/4650 | 9.4/9.4 | 9.4/9.4 | $225 | — | 7.0 | 750 | 212 | 248 | L |
EL36N35B | 724587429954 | 36000/35500 | 17300/14300 | 230/208 | 17.5/19.2 | 4000/3944 | 24.0/22.4 | 5500/4650 | 9.0/9.0 | 9.0/9.0 | $360 | — | 12.0 | 725 | 132 | 153 | L |
* YS10N10C heat pump operates on 115 volt and is NOT equipped with supplemental heat. Will not provide heat at temperatures below 40˚F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 60˚F to 115˚F.
Kühl+ Heat Pump heating information indicates heat pump performance. Kühl+ Electric Heat heating information indicates electric heat strip performance. For Kühl+ Heat Pump electric heating performance refer to corresponding Kühl+ Electric Heat model.
As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® models meet the ENERGY STAR® guidelines for energy efficiency. The consumer, through the AHAM Room Air Conditioner Certification Program, can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio. EER is the unit’s Energy Efficiency Ratio; CEER is the unit’s Combined Energy Efficiency Ratio. Your energy costs will depend on your utility rates and use. The estimated energy cost is based on an electricity cost of $.12 per kWh. For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
Circuit Rating/Breaker/Power Cord:
Model | Circuit Rating Breaker or T-D Fuse | Plug Face (NEMA#) | Power Cord Length (ft.) | Wall Outlet Appearance |
---|---|---|---|---|
All SQ MODELS, EQ08N11D, SS08N10C, SS10N10C, SS12N10C and SS14N10C, YS10N10C, SM14N10. | 125V - 15A | 5-15P | 6 | ![]() |
SS12N30C, SM14N30 and SM18N30B, SM21N30D. | 250V - 15A | 6-15P | 6 | ![]() |
SL24N30C and SL28N30C, ES12N33B and ES14N33, YS12N33C. | 250V - 20A | 6-20P | 6 | ![]() |
SL36N30B, EM18N34A and EM21N34, EL24N35 and EL36N35B, YM18N34C and YL24N35C. | 250V - 30A | 6-30P | 6 | ![]() |
Cooling Sizing Guide:
This guide helps determine the appropriate cooling capacity (Btu) based on the area to be conditioned (in sq. ft.).
Area to be conditioned (sq. ft.) | Approximate Cooling Btu Required |
---|---|
100 - 150 | 5000 |
150 - 250 | 6000 |
250 - 300 | 7000 |
300 - 350 | 8000 |
350 - 400 | 9000 |
400 - 450 | 10000 |
450 - 550 | 12000 |
550 - 700 | 14000 |
700 - 1000 | 18000 |
1000 - 1200 | 21000 |
1200 - 1400 | 23000 |
1400 - 1500 | 24000 |
1500 - 2000 | 30000 |
2000 - 2500 | 34000 |
Notes for Sizing:
- Based on normal room insulation, average number of sun-exposed windows, and two-person occupancy.
- If heavily shaded, reduce cooling Btus required by 10%.
- If very sunny, increase cooling Btus required by 10%.
- Add 500 Btus per person over 2 people.
- Add 4,000 Btus if the area is a kitchen.
All Kühl models use R-410A refrigerant.
Remote Control Information
Premium LCD Remote
The Premium LCD Remote features a full LCD display showing MODE, FAN SPEED, SET TEMPERATURE, and SCHEDULE. It allows adjustment of temperature and fan speeds, setting of AUTO MODE, and turning the SCHEDULE ON/OFF.
Kühl SQ/EQ Models
Kühl SS, SM and SL Models
Kühl+ ES, YS, EM, YM, EL and YL Models
[Diagram showing remote control features]
Installation Considerations
Sleeve Dimensions Drawing:
[Diagram showing side view and sleeve dimensions]
Installation in a window or thru-the-wall
Slideout chassis
Includes heavy duty window installation hardware (optional accessory on Kühl+ models, sold separately)
Rugged hardboard side panels (heavy duty side curtains on SQ and EQ models)
Power cord can run either left or right
Patented firm grip handles for easier chassis install/removal
EntryGard™ anti-intrusion protection secures the chassis to the sleeve to deter ‘kick-in’ intrusion
Aluminum rear grille protects the outdoor coil from debris and vandalism
Warranty Information
LIMITED WARRANTY
[Details about the limited warranty would typically be found here, but are not present in the provided text.]
ENERGY STAR® Information
ENERGY STAR® qualified models are available, meeting ENERGY STAR® guidelines for energy efficiency.
AHAM Certification Seal: Provides assurance of accurate cooling and heating capacity ratings, amperes, and energy efficiency ratio (EER/CEER).
Estimated Energy Cost: Based on an electricity cost of $0.12 per kWh. Actual costs may vary based on utility rates and usage. Visit www.ftc.gov/energy for more information.