GT Series
100-125 kW
A white, rectangular solar inverter unit with a dark grey top panel and a prominent 'GT Series 100-125 kW' label. The unit features ventilation grilles and a small, dark rectangular panel, likely a display or indicator.
Technical Data
GW100K-GT | GW110K-GT | GW125K-GT | |
---|---|---|---|
Input | |||
Max. Input Voltage (V) | 1100 | ||
MPPT Operating Voltage Range (V) | 180 ~ 1000 | ||
Start-up Voltage (V) | 200 | ||
Nominal Input Voltage (V) | 600 | ||
Max. Input Current per MPPT (A) | 42 | ||
Max. Short Circuit Current per MPPT (A) | 52.5 | ||
Number of MPP Trackers | 8 | 10 | 10 |
Number of Strings per MPPT | 2 | 2 | 2 |
Output | |||
Nominal Output Power (kW) | 100*1 | 110 | 125 |
Nominal Output Apparent Power (kVA) | 100*1 | 110 | 125 |
Max. AC Active Power (kW)*3 | 110.0*1 | 121.0*4 | 137.5*2 |
Max. AC Apparent Power (kVA)*3 | 110.0*1 | 121.0*4 | 137.5*2 |
Nominal Output Voltage (V) | 220/380, 230/400, 3L/N/PE or 3L/PE | ||
Output Voltage Range (V) | 304 ~ 460 | ||
Nominal AC Grid Frequency (Hz) | 50/60 | ||
AC Grid Frequency Range (Hz) | 45~55/55~65 | ||
Max. Output Current (A)*5 | 167.1 | 183.4 | 199.4 |
Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ||
Max. Total Harmonic Distortion | <3% | ||
Efficiency | |||
Max. Efficiency | 98.8% | 98.8% | 99.0% |
European Efficiency | 98.4% | 98.4% | 98.5% |
Protection | |||
PV String Current Monitoring | Integrated | ||
PV Insulation Resistance Detection | Integrated | ||
Residual Current Monitoring | Integrated | ||
PV Reverse Polarity Protection | Integrated | ||
Anti-islanding Protection | Integrated | ||
AC Overcurrent Protection | Integrated | ||
AC Short Circuit Protection | Integrated | ||
AC Overvoltage Protection | Integrated | ||
DC Switch | Integrated | ||
DC Surge Protection | Type II (Type I + II Optional) | ||
AC Surge Protection | Type II | ||
AFCI | Optional | ||
Emergency Power Off | Optional | ||
Rapid Shutdown | Optional | ||
Remote Shutdown | Optional | ||
PID Recovery | Optional | ||
Reactive Power Compensation at Night | Optional | ||
Power Supply at Night | Optional | ||
General Data | |||
Operating Temperature Range (°C) | -30 ~ +60 | ||
Relative Humidity | 0 ~ 100% | ||
Max. Operating Altitude (m) | 4000 | ||
Cooling Method | Smart Fan Cooling | ||
User Interface | LED, LCD (Optional), WLAN + APP | ||
Communication | RS485, WiFi + LAN or 4G or PLC (Optional) | ||
Communication Protocols | Modbus-RTU (SunSpec Compliant) | ||
Weight (kg) | 85 | 88 | 88 |
Dimension (W x H x D mm) | 930 x 650 x 300 | ||
Topology | Non-isolated | ||
Self-consumption at Night (W) | <2 | ||
Ingress Protection Rating | IP66 | ||
DC Connector | MC4 (4~6mm²) | ||
AC Connector | OT/DT terminal (Max. 240mm²) | ||
Footnotes: | |||
*1: For Australia is 99.99kW/KVA. | |||
*2: For VDE4105 Max. AC Active Power (kW) and Max. AC Apparent Power (kVA): GW125K-GT is 134.9. | |||
*3: For Chile and Brazil Max. AC Active Power (kW) and Max. AC Apparent Power (kVA): GW100K-GT is 100; GW110K-GT is 110; GW125K-GT is 125. | |||
*4: For Australia is 110kW / kVA. | |||
*5: For Australia Max. Output Current (A): GW100K-GT is 145, GW110K-GT is 159.5. | |||
*: Please visit GoodWe website for the latest certificates. | |||
*: All pictures shown are for reference only. Actual appearance may vary. |