Quick Installation Guide

(Hilbert Industrial Smart Lite Switches)

Content Overview

This document provides a quick installation guide for Level One Hilbert Industrial Smart Lite Switches. It covers power connection, logging onto the equipment, configuring network settings for Windows and macOS, and using the LevelOne IP Locator application. Safety instructions and disposal information are also included.

Power Connecting Procedure

Requirement: For operation, a DC Industrial Power Supply is needed (sold separately).

The procedure involves connecting power using a 4-pin terminal block. The diagram shows redundant power inputs with a terminal block.

Diagram Description: A diagram shows a 4-pin terminal block with screw terminals labeled V1+, V1-, V2+, V2-, and Ground. Arrows indicate wires being connected to these terminals, and the block is shown being inserted back into a device.

Note: DC Industrial Power Supply Sold Separately

Logging On to the Equipment

Connect the RJ-45 interface cable of an industrial switch to a computer using a network cable.

Diagram Description: An illustration shows a laptop computer connected via an RJ-45 cable to a series of Level One Hilbert Industrial Switches. A separate DC Industrial Power Supply unit is depicted, connected via a wire.

Note: The Industrial switch is an indoor device. If you need to use it to connect outdoor devices such as outdoor IP cameras or outdoor WiFi Access Points via cable, you need to install an arrester on the cable between the outdoor device and the switch.

Setting TCP/IP Properties

Windows

  1. Click Start → Control Panel → Network and Internet → Network and Sharing Center → Change adapter settings. Right-click Local Area Connection and select Properties.
  2. Double-click Internet Protocol Version 4 (TCP/IPv4).
  3. Set the computer's IP address: The computer's IP address should be any one of the following free IP addresses: 192.168.1.2 ~ 192.168.1.253. Then click OK to return to the previous page, and click OK again to close the window.
  4. Logging on to the equipment: Open a web browser and type 192.168.1.1 in the address bar, then press Enter. In the pop-up login interface, enter the factory username "admin" and password "admin", then click OK.

Diagram Description: Screenshots illustrate the Windows network configuration steps, including the Network Connections window and the TCP/IP Properties dialog. A browser screenshot shows the login page for 192.168.1.1.

macOS

  1. Click the Apple icon, then from the Apple drop-down list, select System Preferences.
  2. Click the Network icon.
  3. Select Ethernet (for wired connection), and from the Configure IPv4 drop-down list, select Manually.
  4. Set the computer's IP address: The computer's IP address should be any one of the following free IP addresses: 192.168.1.2 ~ 192.168.1.253. Set the Subnet Mask to 255.255.255.0, and then click Apply.
  5. Logging on to the equipment: Open a web browser and type 192.168.1.1 in the address bar, then press Enter. In the pop-up login interface, enter the factory username "admin" and password "admin", then click OK.

Diagram Description: Screenshots illustrate the macOS network configuration steps, including System Preferences, the Network icon, and the IPv4 configuration setting. A browser screenshot shows the login page for 192.168.1.1.

Running the Application

The LevelOne IP Locator is a switch discovery tool compatible with Windows and Mac operating systems. It helps search for Hilbert series switches and find their IP addresses.

  1. Scan the setup code to download and launch the LevelOne IP Locator. The URL is: http://level1.info/iplocator
  2. Execute the application: LevelOne IP Locator.exe.
  3. The LevelOne IP Locator Utility will scan the network for connected Hilbert switches and display their IP addresses and other information.
  4. To access a device for configuration, click its IP address in the device list. On the login screen, enter the factory username "admin" and password "admin", then click "Sign in".

A settings box will appear, allowing you to instantly configure IP addresses and other information.

Diagram Description: A QR code for downloading the LevelOne IP Locator. An icon representing the application executable. Screenshots show the LevelOne IP Locator utility listing devices and the login interface, as well as a dialog for modifying device settings.

Safety and Handling Instructions

⚠️ Explanation of Symbols: The symbol with an exclamation mark in a triangle indicates important information. Always read this information carefully.

Disposal

♻️ WEEE: Dispose of the product at a recycling point. Do not dispose of it with household waste. Incorrect storage or disposal can harm the environment and/or cause injury.

Safety Instructions

Read the operating instructions carefully and observe the safety information. Failure to follow these instructions may invalidate the warranty.

a) General Information

b) People and Product

Care and Cleaning

Models: IGS-2110P Managed L2 Gigabit Ethernet Power over Ethernet Switch, IGS-2110P, Managed L2 Gigabit Ethernet Power over Ethernet Switch, Gigabit Ethernet Power over Ethernet Switch, Power over Ethernet Switch, over Ethernet Switch, Ethernet Switch, Switch

File Info : application/pdf, 38 Pages, 1.59MB

PDF preview unavailable. Download the PDF instead.

mmo 117692359 1717422352 245 6578

References

macOS 版本14.3.1(版號23D60) Quartz PDFContext

Related Documents

Preview Level One Quick Installation Guide - Network Transceivers
Concise installation guide for Level One network transceivers, covering safety, general information, and care. Features plug-and-play installation for networking equipment.
Preview Level One Managed Switches Quick Installation Guide
Provides essential steps for installing and performing initial configuration of Level One Managed Switches, covering rack and desktop mounting, and basic network setup.
Preview LevelOne FSW-1650 and FSW-2450 Fast Ethernet Switch Quick Installation Guide
A quick installation guide for LevelOne FSW-1650 (16-Port) and FSW-2450 (24-Port) Fast Ethernet Switches, covering hardware installation, LED indicators, mode control, and equipment connection.
Preview LevelOne GNC-0113 2.5-Gigabit PCIe Network Card Declaration of Conformity
Official Declaration of Conformity for the LevelOne GNC-0113 2.5-Gigabit PCIe Network Card, detailing compliance with EU legislation and harmonised standards, along with safety and care instructions.
Preview LevelOne WUA-1810E USB WiFi Adapter User Manual
Comprehensive user manual for the LevelOne WUA-1810E USB WiFi Adapter, covering installation, configuration, troubleshooting, and system specifications for Windows and macOS.
Preview Declaration of Conformity - LevelOne XQS-3126 Ethernet Switch
Official Declaration of Conformity for the LevelOne XQS-3126 Ethernet Switch, manufactured by Digital Data Communications GmbH, confirming compliance with key EU and UK regulations including RoHS, EMC, and Low Voltage Directives.
Preview LevelOne WUA-1810 E Quick Installation Guide
This guide provides step-by-step instructions for installing and connecting the LevelOne WUA-1810 E USB WiFi Adapter. It covers connecting the adapter, installing drivers, and establishing a wireless connection.
Preview LevelOne GEP-2421W150: 24-Port Gigabit PoE Switch, 150W
Product overview and technical specifications for the LevelOne GEP-2421W150, a 24-port Gigabit PoE switch with 150W total PoE power budget, IEEE 802.3af/at compliance, and 19-inch rack-mount capability.