Safety Instructions
Model: M540A01
Document No. 1058MM11REV00 Version: 2022-10-19
Manufactured by: i.safe MOBILE GmbH
Address: i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany
Contact: Tel. +49 9343 60148-0 | Email: info@isafe-mobile.com | Website: www.isafe-mobile.com
EX Markings
ATEX: II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T135°C Db
EU Type Examination Certificate: EPS 22 ATEX 1 341 X
CE-designation: 2004
IECEx: Ex ib IIC T4 Gb Ex ib IIIC T135°C Db
IECEx Certificate: IECEx EPS 22.0072X
UKEX: II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T135°C Db
UK Type Examination Certificate: EPS 22 UKEX 1 341 X
UKCA-designation: 2503
Temperature Range: -20°C ... +55°C (EN/IEC 60079-0)
Temperature Range: -10°C ... +55°C (EN/IEC 62368-1)
EX-Relevant Safety Regulations
Use of this device assumes that the operator observes the conventional safety regulations and has read and understood the Operating Manual, Safety Instructions, and certificate.
When used in explosion hazardous areas, the following Safety Instructions must also be complied with:
- Inside explosion hazardous areas, the covers of all interfaces (USB, ISM Interface) must be closed.
- To ensure IP-protection, it must be ensured that all gaskets are present and functional. There must be no large gap between the two halves of the housing and between the battery compartment cover and housing.
- The device may only be charged outside explosion hazardous areas using the i.safe PROTECTOR 2.0 USB-C Cable or other charging equipment approved by i.safe MOBILE GmbH.
- The Headset IS-HS2A.1 or other accessories approved by i.safe MOBILE GmbH may be used within explosion hazardous areas only if connected to the ISM interface. The connector must be securely fastened to the ISM interface.
- microSD cards type IS-SD164.1 and IS-SD1128.1, or microSD cards complying with the intrinsic safety entity parameters mentioned in the certificate, may be used in the corresponding slot in the hazardous area.
- Nano-SIM cards complying with the intrinsic safety entity parameters mentioned in the certificate, may be used in the corresponding slot in the hazardous area.
- The device may only be charged at ambient temperatures between 0°C ... +45°C.
- The device may not be exposed to any aggressive acids or alkalis.
- The device may only be used in zones 1, 2, 21, or 22.
Information Concerning SAR Certification (Specific Absorption Rate)
The SAR limit of Europe is 2.0 W/kg for the head and body, and 4.0 W/kg for the limbs. The device has been tested against this SAR limit.
The highest SAR value reported under this standard during product certification for use at the ear is 0.72 W/kg, when correctly worn on the body is 1.44 W/kg, and for limbs is 3.08 W/kg.
This device was tested for typical body-worn operations with the back of the handset kept 5 mm from the body. The device complies with RF specifications when used at 5 mm from the body. Belt clips, holsters, and similar accessories used should not contain metallic components in the assembly. The use of accessories that do not satisfy these requirements may not comply with RF exposure requirements and should be avoided.
Restrictions in the 5 GHz Band
According to Article 10 (10) of Directive 2014/53/EU, the packaging shows that this radio equipment will be subject to some restrictions when placed on the market in Belgium (BE), Bulgaria (BG), the Czech Republic (CZ), Denmark (DK), Germany (DE), Estonia (EE), Ireland (IE), Greece (EL), Spain (ES), France (FR), Croatia (HR), Italy (IT), Cyprus (CY), Latvia (LV), Lithuania (LT), Luxembourg (LU), Hungary (HU), Malta (MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT), Romania (RO), Slovenia (SI), Slovakia (SK), Finland (FI), Sweden (SE), the United Kingdom (UK), Turkey (TR), Norway (NO), Switzerland (CH), Iceland (IS), and Liechtenstein (LI).
The WLAN function for this device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range.
Affected Countries: AT, BE, BG, CH, CY, CZ, DE, DK, EE, EL, ES, FI, FR, HR, HU, IE, IS, IT, LI, LT, LU, LV, MT, NL, PL, PT, RO, SE, SI, SK, TR, UK
EU/UK Declaration of Conformity
This section confirms the compliance of the device with relevant EU and UK regulations. For complete details, please refer to the official Declaration of Conformity document provided by i.safe MOBILE GmbH.