Quick Guide for 8kW Water Heaters
Brand: Airthereal
Important Installation Note
This unit should be installed by a qualified professional in accordance with all national, state, provincial and local electrical & plumbing codes.
Tools You'll Need
- Voltage tester: A digital multimeter with probes. [Image: Digital multimeter with probes]
- Screwdrivers: For making connections and mounting. [Image: Screwdriver]
- Pliers: For gripping and manipulating wires. [Image: Pliers]
- Wire strippers: For preparing wire ends. [Image: Wire strippers]
Electrical Requirements & Safety
⚡DANGER: HIGH VOLTAGE
⚡ELECTRIC SHOCK RISK
240V not 120V
Confirm that your breaker panel can meet the required specifications for your unit: 8kW: 240V Outlet, 1x 40A Double Pole Circuit Breaker.
[Image: Close-up of a 40A double-pole circuit breaker labeled "40" on both poles.]
⚠️ If you do not have the correct infrastructure, you will need a professional to install a new outlet, breaker, and/or wiring.
⚠️ Under no circumstances should you attempt to clean, install, inspect, repair, disassemble or otherwise service this water heater without first shutting off all power to the unit directly at the circuit breaker box. Serious bodily injury or death could occur if you ignore this warning.
Installation Steps
[Image: A hand is shown flipping a circuit breaker switch in a breaker panel.]
[Image: Close-up of a double-pole circuit breaker with wires being connected. The wires are labeled: L1: Neutral wire (black) and L2: Live wire (red). The wire gauge appears to be 8 AWG.]
[Image: A grounding bus bar with multiple yellow and green striped wires connected to it.]
- Turn off the Power at the main breaker.
- Take each wire pair and connect them to one breaker. Ensure each breaker is connected with one black wire and one red wire.
- Using a suitable wire gauge that meets all applicable electrical codes for the size of the breakers used, run the correct sets of wire from the main breaker panel to the tankless water heater.
- A separate ground conductor is required.
- Double-check the electrical connections to make sure they are correct and that all wire connections are tight and secure.