Product Overview
This document provides an overview, specifications, and precautions for the AIGOSTAR Low-Voltage Dedicated External Power Supply.
The power supply features:
- AC Input Terminals: For connecting the main power supply. These include Ground wire (?), Neutral wire (〰️), and Live wire (⚡).
- Lamp Output Terminals: For connecting the load (e.g., LED lights). These include Negative pole (➖) and Positive pole (➕).
The physical layout includes terminals for AC input and lamp output, with clear labeling for polarity.
Specifications
Model | Power | Input Voltage | Output Voltage | Output Current | Over Current | Working Temperature | Dimension |
---|---|---|---|---|---|---|---|
FHYLA100W24V | 100W | 220-240V | 24V | 4.1A | 3.74-4.99A | -25°C~35°C | 140*50*25 mm |
FHYLA150W24V | 150W | 220-240V | 24V | 6.3A | 5.62-7.5A | -25°C~35°C | 160*50*25 mm |
FHYLA200W24V | 200W | 220-240V | 24V | 8.3A | 7.5-9.99A | -25°C~35°C | 200*50*25 mm |
Precautions
- It is recommended to use a load power of no more than 80% to extend the service life.
- Do not operate while the power is on to avoid the risk of electric shock.
- When outputting, try to use multiple parallel connections to reduce line loss of a single line.
- Avoid using in humid environments to reduce the risk of damage to the power supply due to moisture.