Instruction Manual for ifm models including: DV15x0 5 Segment Light Tower, DV15x0, 5 Segment Light Tower, Segment Light Tower, Light Tower, Tower
IFM DV2510 (01) PDF MANUAL - Manual-Hub.com
File Info : application/pdf, 22 Pages, 1.01MB
DocumentDocumentOperating instructions 5-segment signal lamp DV15x0 UK DV25x0 https://manual-hub.com/ 80263024 / 00 07 / 2019 Contents 1 Preliminary note4 11 Key to the symbols 4 2 Safety instructions 5 3 Functions and features 5 31 IO-Link 6 311 General information 6 312 Device-specific information6 4 Installation6 5 Electrical connection7 51 IO-Link connection7 6 Pin configuration8 61 IO-Link device (DV25x0) 8 62 Standard device (DV15x0) 8 7 Operating and display elements 9 8 Operation10 81 Operation of the IO-Link version10 811 General10 812 On/off mode10 813 RGB mode 11 814 Analogue mode12 82 Operation of the standard version 14 83 Demo mode 14 9 Parameter setting 14 91 IO-Link version14 92 Standard version 15 921 Parameter structure16 10 Scale drawing 17 101 DVx50017 102 DVx51018 103 DVx52019 104 DVx53020 2 https://manual-hub.com/ 11 Technical data 21 111 IO-Link device21 12 Maintenance, repair and disposal22 121 Cleaning the housing surface 22 13 Approvals/standards 22 UK https://manual-hub.com/ 3 1 Preliminary note Technical data, approvals, accessories and further information at wwwifmcom 1.1 Key to the symbols Instructions > Reaction, result [...] Designation of keys, buttons or indications Cross-reference Important note Non-compliance may result in malfunction or interference Information Supplementary note WARNING Warning of serious personal injury Death or serious irreversible injuries may result CAUTION Warning of personal injury Slight reversible injuries may result ATTENTION Warning of damage to property 4 https://manual-hub.com/ 2 Safety instructions · Read this document before setting up the product and keep it during the entire service life · The product must be suitable for the corresponding applications and environmental conditions without any restrictions · Only use the product for its intended purpose ( 3 Functions and features) · If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur · The manufacturer assumes no liability or warranty for any consequences UK caused by tampering with the product or incorrect use by the operator · Installation, electrical connection, set-up, operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator · Protect units and cables against damage 3 Functions and features The unit is used to visually display machine conditions The versions DVx510 and DVx530 additionally have a buzzer for acoustic signalling The 5 LED segments and the audible warning device can be switched on and off individually The device is intended for indoor use only Observe the operating conditions ( 11 Technical data) The unit must not be used for safety-related applications such as access control The standard units are DV15xx The DV25xx units are IO-Link devices The IO-Link version can be triggered and configured via the standard IO-Link interface With the standard version the individual LED segments can be switched individually via digital inputs Parameters are set via a parameter setting button or via an additional IO-Link interface If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired https://manual-hub.com/ 5 3.1 IO-Link 3.1.1 General information This unit has an IO-Link communication interface which enables direct access to process and diagnostic data In addition it is possible to set the parameters of the unit while it is in operation Operation of the unit via an IO-Link interface requires an IO-Link capable module (IO-Link master) 3.1.2 Device-specific information With a PC, suitable IO-Link software and an IO-Link adapter cable communication is possible when the system is not in operation The IODDs necessary for the configuration of the unit, detailed information about process data structure, diagnostic information, parameter addresses and the necessary information about the required IO-Link hardware and software can be found at wwwifmcom 4 Installation Disconnect power before installation For installation choose a flat mounting surface 43 1 18 4 20 M4 Fixture (view from bottom) 1: Front side Attach the fixture for the unit to the mounting surface using the supplied M4 nuts Tightening torque 18 Nm Only with the models DVx500 and DVx510: For mounting on a horizontal surface attach the base to the fixture (overlapping marks on base and fixture) and turn clockwise by approx 10 ° to fix it For mounting on a vertical surface loosen the screw in the base, turn the upper part 6 https://manual-hub.com/ of the base by 180 ° and tighten the screw again Attach the base to the fixture (overlapping marks on base and fixture) and turn clockwise by approx 10 ° to fix it Insert the cable through the fixture and, if necessary, the base and connect the socket with the M12 connector in the signal lamp Tightening torque max 1 Nm Attach the signal lamp to the fixture or the base (overlapping marks) and turn clockwise by approx 10 ° to fix it Observe the maximum tightening torque of the connection cable UK Integrated seals at the bottom of the fixture and in the base as well as O-rings at the fixture and base prevent ingress of moisture More information about available accessories at wwwifmcom 5 Electrical connection The unit must be connected by a qualified electrician The national and international regulations for the installation of electrical equipment must be adhered to Voltage supply according to SELV, PELV Disconnect power Connect the unit 5.1 IO-Link connection The IO-Link port must be connected according to the IO-Link specification https://manual-hub.com/ 7 6 Pin configuration 6.1 IO-Link device (DV25x0) M12 connector IO-Link, 4 poles (4 x 034 mm² / AWG 22) 1: UB+ 2: not used 3: UB4: IO-Link 21 34 6.2 Standard device (DV15x0) M12 connector, 8 poles (8 x 025 mm² / AWG 24) 1: LED segment 5 2: buzzer (DV1510 and DV1530) 3: LED segment 3 4: LED segment 2 5: voltage supply 6: LED segment 1 7: LED segment 4 8: IO-Link 2 18 3 7 456 The input polarity is selectable Connect pin 5 to +24 V DC to trigger the inputs with an NPN transistor Connect pin 5 to GND to trigger the inputs with a PMP transistor When triggered via IO-Link (pin 8) without connection cable E12572: Connect pin 5 to +24 V DC Connect pin 3 to GND 8 https://manual-hub.com/ 7 Operating and display elements 8 1 2 3 4 5 UK 6 7 1: Parameter setting button (only DV15x0) 2: LED segment 1 with 4 RGB LEDs 3: LED segment 2 with 4 RGB LEDs 4: LED segment 3 with 4 RGB LEDs 5: LED segment 4 with 4 RGB LEDs 6: LED segment 5 with 4 RGB LEDs 7: Buzzer (only DVx510 and DVx530) 8: Feedback LED (only DV15x0) https://manual-hub.com/ 9 8 Operation 8.1 Operation of the IO-Link version 8.1.1 General The unit is connected to an IO-Link master (A port) with a 4-pole connection cable The controller switches the individual LED segments on and off in the configured colours according to the set parameters Via the parameter "Operating mode" the following modes can be set: · On/off mode · RGB mode · Analogue mode 8.1.2 On/off mode While in operation, the controller switches the 5 LED segments and the buzzer (only with DVx510 and DVx530) on and off (PDout, cyclical data communication) Signalling corresponds to the pre-defined parameters for the individual LED segments and the buzzer Via the acyclic parameter setting the following properties can be set for every LED segment: · Colour (red, green, orange, blue, violet, turquoise, white, yellow, off) · Frequency (permanently on, low flash rate slow/medium/fast, high flash rate slow/medium/fast) · Brightness (100 %, 75 %, 50 %, 25 %) For the models with an acoustic signal device the audibility of the buzzer can be set 7 6 5 4 3 2 1 0 PDout Seg 5 Seg 4 Seg 3 Seg 2 Seg 1 Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Buzzer sound (buzzer style 18) Buzzer Byte 5 10 https://manual-hub.com/ 8.1.3 RGB mode While in operation the controller switches the 5 LED segments and the buzzer on and off (only with DVx510 and DVx530), defining the respective properties (PDout, cyclical data communication) In this operating mode, 8 different acoustic signals are available for the buzzer 7 6 5 4 3 2 1 0 PDout Segment 1 LED properties Segment 2 LED properties Seg 1 yellow Seg 2 yellow Seg 1 red Seg 2 red Seg 1 green Seg 2 green Seg 1 blue Seg 2 blue Byte 0 Byte 1 UK Segment 3 LED properties Seg 3 yellow Seg 3 red Seg 3 green Seg 3 Byte 2 blue Segment 4 LED properties Seg 4 yellow Seg 4 red Seg 4 green Seg 4 Byte 3 blue Segment 5 LED properties Seg 5 yellow Seg 5 red Seg 5 green Seg 5 Byte 4 blue Buzzer sound (buzzer style 18) Buzzer Byte 5 The properties of the LED segments are defined as follows: 3 2 1 0 0 0 0 0 0 1 0 0 0 0 1 0 0 1 1 0 0 0 0 1 0 1 0 1 0 0 1 1 0 1 1 1 1 0 0 0 Colour off red green orange blue violet turquoise white yellow https://manual-hub.com/ 11 6 5 4 Frequency 0 0 0 permanently on 0 0 1 low flash rate slow 0 1 0 low flash rate medium 0 1 1 low flash rate fast 1 0 0 high flash rate slow 1 0 1 high flash rate medium 1 1 0 high flash rate fast 8.1.4 Analogue mode While in operation the controller transmits an analogue value between 0 and 100 % in byte 0 via PDout % Byte 1 determines the representation of the visual signalling 9 different representations are possible Byte 5 defines the acoustic signal (only with DVx510 and DVx530) 8 different acoustic signals are available 7 6 5 4 3 2 1 0 PDout Analogue value 0100 % Byte 0 Representation LED (style 19) Byte 1 Byte 2 Byte 3 Byte 4 Buzzer sound (buzzer style 18) Buzzer Byte 5 12 https://manual-hub.com/ The signal lamp generates the following visual indications of the analogue value depending on the data in byte 1 Analogue value: 0 % 1-10 % 11-20 % 21-30 % 31-40 % 41-50 % 51-60 % 61-70 % 71-80 % 81-90 % 91-99 % 100 % Style 1 white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 Style 2 Style 3 white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 white white white white white Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 UK Style 4 white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 Style 5 Style 6 green green green green blue green green green green blue green green green green blue green green green blue green green green green blue green green green blue green green green green blue green green green blue green green green green blue green green green blue green green green green blue green green green green blue green green green green Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 red red red red red red red red red blue blue blue Segment 1 red red red red red red red blue blue red red red Segment 2 red red red red red blue blue red red red red red Segment 3 red red red blue blue red red red red red red red Segment 4 blue blue blue red red red red red red red red red Segment 5 Style 7 orange orange orange orange blue orange orange orange orange blue orange orange orange orange blue orange orange orange blue orange orange orange orange blue orange orange orange blue orange orange orange orange blue orange orange orange blue orange orange orange orange blue orbalunege orange orange blue orange orange orange orange blue orange orange orange orange blue orange orange orange orange Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 Style 8 white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 Style 9 white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 Style 10 yellow yellow yellow yellow blue yellow yellow yellow yellow blue yellow yellow yellow yellow blue yellow yellow yellow blue yellow yellow yellow yellow blue yellow yellow yellow blue yellow yellow yellow yellow blue yellow yellow yellow blue yellow yellow yellow yellow blue yellow yellow yellow blue yellow yellow yellow yellow blue yellow yellow yellow yellow blue yellow yellow yellow yellow Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 https://manual-hub.com/ 13 8.2 Operation of the standard version The unit is connected to the digital outputs of the controller via an 8-pole cable (see accessories at wwwifmcom) The 6 HTTL inputs of the signal lamp are triggered with 24 V DC According to the set parameters, the 5 LED segments are on and the buzzer sounds (only with DVx510 and DVx530) The signal inputs can be triggered either in PNP or in NPN technology ( 6.2 Standard device (DV15x0)) With the parameter setting button the following properties can be set for every LED segment: · Colour (red, green, orange, blue, violet, turquoise, white, yellow, off) · Frequency (permanently on, low flash rate slow/medium/fast, high flash rate slow/medium/fast) · Brightness (100 %, 75 %, 50 %, 25 %) Parameter setting via the IO-Link interface (pin 8 of the M12 connector) is also possible After parameter setting, the unit goes to the Run mode 8.3 Demo mode In demo mode, the unit demonstrates the different · colours · visual indications of analogue values (styles) · buzzer sounds (buzzer styles, provided the unit features a buzzer) Set the parameter [Demo mode] in the IO-Link parameter setting tool (eg LR DEVICE) For SIO and IO-Link mode, the demo is available in 3 different speeds, respectively 9 Parameter setting 9.1 IO-Link version The unit can be configured using an IO-Link parameter setting tool (eg LR DEVICE) ( 3.1 IO-Link) More information is given in the IODD at wwwifmcom 14 https://manual-hub.com/ 9.2 Standard version Turn the transparent protective cover anticlockwise by approx 10 ° and remove it Briefly press the parameter setting button at the head of the unit (< 5 s) > The feedback LED is green on The unit is in the parameter setting mode Briefly press the parameter setting button (< 5 s) to go to the next parameter Press the parameter setting button for a longer time (> 5 s) to set the selected parameter UK > The feedback LED flashes green The unit indicates the current settings of the LED segment to be configured Briefly press the parameter setting button (< 5 s) to change the value for the selected parameter Repeat this step until the requested setting is selected > The unit indicates the current settings of the LED segment to be configured Press the parameter setting button for a longer time (> 5 s) to save the selected value for this parameter > The feedback LED flashes green The unit saves the value and goes to the next parameter > After configuration of all LED segments the unit displays the current settings of all LED segments Briefly press the parameter setting button (< 5 s) to finish the parameter setting mode > The feedback LED goes out The unit is in the Run mode If the parameter setting button is not pressed for longer than 30 seconds, the unit saves the last changes and goes to the Run mode https://manual-hub.com/ 15 9.2.1 Parameter structure LED Parameter seg Value 1 Colour red green orange blue violet turquoise white yellow off Frequency on low flash low flash low flash high high high rate rate rate fast flash rate flash rate flash rate slow medium slow medium fast Brightness 100 75 % 50 % 25 % % 2 Colour red green orange blue violet turquoise white yellow off Frequency on low flash low flash low flash high high high rate rate rate fast flash rate flash rate flash rate slow medium slow medium fast Brightness 100 75 % 50 % 25 % % 3 Colour red green orange blue violet turquoise white yellow off Frequency on low flash low flash low flash high high high rate rate rate fast flash rate flash rate flash rate slow medium slow medium fast Brightness 100 75 % 50 % 25 % % 4 Colour red green orange blue violet turquoise white yellow off Frequency on low flash low flash low flash high high high rate rate rate fast flash rate flash rate flash rate slow medium slow medium fast Brightness 100 75 % 50 % 25 % % 5 Colour red green orange blue violet turquoise white yellow off Frequency on low flash low flash low flash high high high rate rate rate fast flash rate flash rate flash rate slow medium slow medium fast Brightness 100 75 % 50 % 25 % % 16 https://manual-hub.com/ 10 Scale drawing 10.1 DVx500 UK 213 344 17 100 14 25 Dimensions [mm] 40 70 M4x1 M12x1 15 18 https://manual-hub.com/ 17 10.2 DVx510 1 213 384 57 100 14 25 1: Buzzer Dimensions [mm] 18 40 70 M4x1 M12x1 15 18 https://manual-hub.com/ 10.3 DVx520 213 244 UK 14 17 15 Dimensions [mm] 40 70 M4x1 M12x1 18 https://manual-hub.com/ 19 10.4 DVx530 213 284 1 14 57 15 1: Buzzer Dimensions [mm] 40 70 M4x1 M12x1 18 20 https://manual-hub.com/ 11 Technical data DV1500 DV1510 DV1520 DV1530 DV2500 DV2510 DV2520 DV2530 Operating voltage DC [V] Nominal voltage DC [V] Current consumption [mA] Input current [mA] Max buzzer volume [dB] Degree of soiling Ambient temperature [°C] Storage temperature [°C] Max permissible relative [%] humidity Maximum operating altitude [m] Permissible air pressure [hPa] IO-Link Connectors 1830 24 200 RMS (400 mA for 50 ms) typ 6 (24 V DC, high signal) UK - 85 - 85 - 85 - 85 2 -25...50 -40...75 90 2000 above sea level 1060 - - - - M12 connector, 8 poles M12 connector, 4 poles 11.1 IO-Link device Transmission type IO-Link revision SDCI standard IO-Link device ID DV15xx DV25xx SIO mode Input load current at input C/Q [mA] to V0 (ILL) Required master port type Min process cycle time [ms] COM2 (384 kbaud) 11 IEC 61131-9 850 d / 00 03 52 h 841 d / 00 03 49 h Yes < 250 A 32 https://manual-hub.com/ 21 12 Maintenance, repair and disposal The unit is maintenance-free After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations 12.1 Cleaning the housing surface Disconnect the device Clean the device from dirt using a soft, chemically untreated and dry cloth In case of heavy dirt, use a damp cloth Micro-fibre cloths without chemical additives are recommended 13 Approvals/standards EC declarations of conformity, approvals, etc at wwwifmcom 22 https://manual-hub.com/