User Manual for EPEVER models including: LS-E-EU Series-5A 30A PWM Charge Controller, LS-E-EU Series-5A 30A, PWM Charge Controller, Charge Controller, Controller
LS-E(EU) Series(5A~30A) PWM Charge Controller - EPEVER
File Info : application/pdf, 2 Pages, 287.33KB
DocumentDocumentHUIZHOU EPEVER TECHNOLOGY CO., LTD. Thank you for selecting the LandStar E/EU series solar charge controller. Please read this manual carefully before using the product and pay attention to the safety information. Do not install this product in humid, salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments. Solar Charge Controller 1. Safety Information Read all the instructions in the manual before installation. DO NOT disassemble or attempt to repair the controller. Install an external fast-acting fuse or breaker as required. Disconnect the solar module and fast-acting fuses/breakers near the battery before installing or moving the controller. Power connections must remain tight to avoid excessive heating from a loose connection. Only charge batteries that comply with the controller's parameters. The battery connection may be a single battery or a bank of batteries. Risk of electric shock! The PV and load can produce high voltages when the controller is working. 2. Overview The LandStar E/EU series controller is a PWM charge controller that adopts the most advanced digital technique. It's an easy operation and cost-efficient controller featured as: 3-Stage intelligent PWM charging: Bulk, Boost/Equalize, and Float Support 3 charging options: Sealed, Gel, and Flooded Battery status LED indicator indicates battery situation Battery temperature compensation function With humanized settings, the operation is more comfortable and convenient The USB provides a power supply that can charge electronic equipment(LS EU series only) Battery type and load output can be set via the button Extensive Electronic protection 3. Product Features Figure 1 Product Feature PV Terminals Battery Terminals Load Terminals USB output interface (LS EU series only) Mounting Hole 4.5 Load Switch Button Battery status LED indicator Load status LED indicator Charging status LED indicator 4. Wiring Connect the system in the order of battery load PV array following Figure 2-2," Schematic Wiring Diagram," and disconnect the system in the reverse order. NOTE: Do not connect the circuit breaker or fast-acting fuse while wiring the controller. Ensure that the leads of "+" and "-" poles are connected correctly. NOTE: A fast-acting fuse whose current is 1.25 to 2 times the controller's rated current must be installed on the battery side with a distance from the battery not greater than 150 mm. WARNING: The controller has no PV reverse connection protection; please connect it correctly. 1 Tel: +86-752-3889706 Website: www.epever.com Figure 2 Connection diagram 5. LED Indicators 1) Charging and load status indicator Indicator Charging status LED indicator Color Green Status On Solid OFF Fast Flashing Load status LED indicator Green On Solid OFF Slowly Flashing Fast Flashing 2) Battery status indicator Instruction In Charging No Charging Battery Over Voltage Load ON Load OFF Overload Load short circuit LED1 LED2 LED3 LED4 Battery Status Slowly Flashing × × × Under voltage Fast Flashing × × × Over-discharge Battery LED indicator status during voltage is up × × 12.8V Ubat13.4V × 13.4V Ubat14.1V 14.1V Ubat Battery LED indicator status during voltage is down × 12.8VUbat13.4V × × 12.4VUbat12.8V × × × Ubat12.4V NOTE: The above voltage values are measured in the 12V system at 25; please double the values in the 24V system. "" states LED indicator on; "×" states LED indicator off. 6. Operating 1) Load ON/OFF Setting Press the button to control the load output when the controller is powered on. 2) Battery Type Setting Operation: Step 1: Enter the setting mode by pressing the button for 5s until the battery status LEDs are flashing. Step 2: Select the desired mode by pressing the button. Step 3: The mode is saved automatically without any operation for 5S, and the LED stops flashing. Battery Type Indicator shows as below: LED1 LED2 LED3 Battery type × × Sealed(Default) × Gel Flooded NOTE: "" states LED indicator on "×" states LED indicator off 2 HUIZHOU EPEVER TECHNOLOGY CO., LTD. Battery Voltage Control Parameters Below parameters are measured in the 12V system at 25 ºC; please double the values in the 24V system Battery Type Sealed Gel Flooded Over Voltage Disconnect Voltage 16.0V 16.0V 16.0V Charging Limit Voltage 15.0V 15.0V 15.0V Over Voltage Reconnect Voltage 15.0V 15.0V 15.0V Equalize Charging Voltage Boost Charging Voltage 14.6V 14.4V ---- 14.2V 14.8V 14.6V Float Charging Voltage 13.8V 13.8V 13.8V Boost Reconnect Charging Voltage 13.2V 13.2V 13.2V Low Voltage Reconnect Voltage 12.6V 12.6V 12.6V Under Voltage Warning Reconnect Voltage 12.2V 12.2V 12.2V Under Voltage Warning Voltage 12.0V 12.0V 12.0V Low Voltage Disconnect Voltage 11.1V 11.1V 11.1V Discharging Limit Voltage 10.6V 10.6V 10.6V Equalize Duration Boost Duration 120 min. 120 min. ---- 120 min. 120 min. 120 min. 7. Protection Battery Over Voltage Protection When the battery voltage reaches the Over Voltage Disconnect Voltage(OVD), the controller stops charging the battery to protect the battery from being overcharged. Battery Over Discharge Protection When the battery voltage reaches the Low Voltage Disconnect Voltage(LVD), the controller stops discharging the battery to protect the battery from being over-discharged. Overload Protection The load is switched off after a delay when the load current exceeds 1.25 times the rated current. The user must reduce the load appliance, press the button, or restart the controller. Load Short Circuit Protection The load is switched off when the load short circuit (3 times the rated current) happens. The user must clear the short circuit faults, press the button, or restart the controller. High Voltage Transients Protection The controller is protected against small high voltage transients. In Tel: +86-752-3889706 Website: www.epever.com lightning-prone areas, an external lightning arrester is recommended. 8. Troubleshooting Faults Possible reasons Troubleshooting The charging LED turns off during the daytime when sunshine falls on PV PV array disconnection Confirm that PV and battery wire connections are correct and tight. modules properly. Battery voltage Measure battery voltage with No LED indicator may be less than the multi-meter. Min.8V can 8V start up the controller. Charging LED fast flashes. Battery over voltage Check if the battery voltage is higher than the OVD, and disconnect the PV. The load will recover when the LED1 fast flashes. Battery over-discharged battery voltage is restored to or above the LVR (low voltage reconnect voltage). Please reduce the number Load LED flashes slowly. Overload of electric equipment. Press the button or restart the controller. Check carefully loads Load LED fast flashes. Load short circuit connection, clear the fault. Press the button or restart the controller. When the load current exceeds 1.25 times, 1.5 times, and 2 times the rated value, the controller can automatically turn off loads after 60s, 5s, and 1s, respectively. 10. Disclaimer This warranty does not apply under the following conditions: Damage from improper use or use in an unsuitable environment. PV or load current, voltage, or power exceeds the controller's rated value. User disassembly or attempted to repair the controller without permission. The controller is damaged due to natural elements such as lighting. The controller is damaged during transportation and shipment. 9. Technical Specifications Item Nominal system voltage Rated charge current Rated discharge current Battery input voltage range Max. PV open circuit voltage Self-consumption Charge Circuit Voltage Drop Discharge Circuit Voltage Drop USB input interface Temperature compensation coefficient Environment temperature Humidity Enclosure Grounding Dimension(L x W x H) Mounting size Mounting hole size Terminals Net weight LS0512E LS1012E LS1024E LS2024E 12VDC 12/24VDC Auto 5A 10A 20A 5A 10A 20A LS0512EU LS1012EU LS1024EU LS2024EU LS3024EU 12VDC 12/24VDC Auto 5A 10A 20A 30A 5A 10A 20A 30A 8V16V 8V32V 8V16V 8V32V 30V 50V 0.21V 30V 12V5mA; 24V7mA 50V 0.13V 0.12V -- 0.17V 5VDC/1.2A 5VDC/2A -5mV//2V IP30 92.8x65 x20.2mm 84.4mm 101.2x67 x21.8mm 92.7mm 101.2x67 x21.8mm 92.7mm 14AWG/2.5mm2 12 AWG/4mm2 12AWG/4mm2 0.07kg 0.08kg 0.08kg -35 +50 128x85.6 x34.8mm 118mm 10AWG/6mm2 0.15kg 95%,(N.C.) IP20 Common Positive 109.7x65.5 120.3x67 120.3x67 148x85.6 148x106.8 x20.8mm x21.8mm x21.8mm x34.8mm X43.7mm 100.9mm 111.5mm 138mm 4.5 14AWG/2.5mm2 12AWG/4mm2 12AWG/4mm2 10AWG/6mm2 8AWG/10mm2 0.09kg 0.10kg 0.10kg 0.18kg 0.29kg Any changes without prior notice! Version number: V4.2 3 4