User Manual for EPEVER models including: LS-E-EU Series-5A 30A PWM Charge Controller, LS-E-EU Series-5A 30A, PWM Charge Controller, Charge Controller, Controller

User

Download File

LS-E(EU) Series(5A~30A) PWM Charge Controller - EPEVER


File Info : application/pdf, 2 Pages, 287.33KB

PDF preview unavailable. Download the PDF instead.

LS-E-EU-Manual-EN-V4.2
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
Thank you for selecting the LandStar E/EU series solar charge controller. Please read this manual carefully before using the product and pay attention to the safety information.
Do not install this product in humid, salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
Solar Charge Controller
1. Safety Information
 Read all the instructions in the manual before installation.  DO NOT disassemble or attempt to repair the controller.  Install an external fast-acting fuse or breaker as required.  Disconnect the solar module and fast-acting fuses/breakers near the battery
before installing or moving the controller.  Power connections must remain tight to avoid excessive heating from a
loose connection.  Only charge batteries that comply with the controller's parameters.  The battery connection may be a single battery or a bank of batteries.  Risk of electric shock! The PV and load can produce high voltages when the
controller is working.
2. Overview
The LandStar E/EU series controller is a PWM charge controller that adopts the most advanced digital technique. It's an easy operation and cost-efficient controller featured as:  3-Stage intelligent PWM charging: Bulk, Boost/Equalize, and Float  Support 3 charging options: Sealed, Gel, and Flooded  Battery status LED indicator indicates battery situation  Battery temperature compensation function  With humanized settings, the operation is more comfortable and convenient  The USB provides a power supply that can charge electronic equipment(LS
EU series only)  Battery type and load output can be set via the button  Extensive Electronic protection
3. Product Features

Figure 1 Product Feature

 PV Terminals

 Battery Terminals

 Load Terminals



USB output interface (LS EU series only)

 Mounting Hole 4.5

 Load Switch Button  Battery status LED indicator  Load status LED indicator



Charging status LED indicator

4. Wiring
Connect the system in the order of battery  load PV array following Figure 2-2," Schematic Wiring Diagram," and disconnect the system in the reverse order.

NOTE: Do not connect the circuit breaker or fast-acting fuse while wiring the controller. Ensure that the leads of "+" and "-" poles are connected correctly.

NOTE: A fast-acting fuse whose current is 1.25 to 2 times the controller's rated current must be installed on the battery side with a distance from the battery not greater than 150 mm.

WARNING: The controller has no PV reverse connection protection; please connect it correctly.

1

Tel: +86-752-3889706

Website: www.epever.com

Figure 2 Connection diagram
5. LED Indicators

1) Charging and load status indicator

Indicator
Charging status LED indicator

Color Green

Status On Solid
OFF
Fast Flashing

Load status LED indicator

Green

On Solid OFF
Slowly Flashing Fast Flashing

2) Battery status indicator

Instruction In Charging No Charging Battery Over
Voltage Load ON Load OFF Overload Load short circuit

LED1

LED2 LED3 LED4

Battery Status

Slowly Flashing ×

×

×

Under voltage

Fast Flashing

×

×

×

Over-discharge

Battery LED indicator status during voltage is up





×

×

12.8V Ubat13.4V







×

13.4V Ubat14.1V









14.1V  Ubat

Battery LED indicator status during voltage is down







×

12.8VUbat13.4V





×

×

12.4VUbat12.8V



×

×

×

Ubat12.4V

NOTE:  The above voltage values are measured in the 12V system at 25; please

double the values in the 24V system.  "" states LED indicator on; "×" states LED indicator off.

6. Operating

1) Load ON/OFF Setting

Press the button to control the load output when the controller is powered on. 2) Battery Type Setting

Operation: Step 1: Enter the setting mode by pressing the button for 5s until the battery status LEDs are flashing.
Step 2: Select the desired mode by pressing the button.
Step 3: The mode is saved automatically without any operation for 5S, and the LED stops flashing. Battery Type Indicator shows as below:

LED1

LED2

LED3

Battery type



×

×

Sealed(Default)





×

Gel







Flooded

NOTE: "" states LED indicator on "×" states LED indicator off

2

HUIZHOU EPEVER TECHNOLOGY CO., LTD.

Battery Voltage Control Parameters Below parameters are measured in the 12V system at 25 ºC; please double the values in the 24V system

Battery Type

Sealed

Gel

Flooded

Over Voltage Disconnect Voltage

16.0V

16.0V

16.0V

Charging Limit Voltage

15.0V

15.0V

15.0V

Over Voltage Reconnect Voltage

15.0V

15.0V

15.0V

Equalize Charging Voltage Boost Charging Voltage

14.6V 14.4V

---- 14.2V

14.8V 14.6V

Float Charging Voltage

13.8V

13.8V

13.8V

Boost Reconnect Charging Voltage

13.2V

13.2V

13.2V

Low Voltage Reconnect Voltage

12.6V

12.6V

12.6V

Under Voltage Warning Reconnect Voltage

12.2V

12.2V

12.2V

Under Voltage Warning Voltage

12.0V

12.0V

12.0V

Low Voltage Disconnect Voltage

11.1V

11.1V

11.1V

Discharging Limit Voltage

10.6V

10.6V

10.6V

Equalize Duration Boost Duration

120 min. 120 min.

---- 120 min.

120 min. 120 min.

7. Protection
 Battery Over Voltage Protection When the battery voltage reaches the Over Voltage Disconnect Voltage(OVD), the controller stops charging the battery to protect the battery from being overcharged.
 Battery Over Discharge Protection When the battery voltage reaches the Low Voltage Disconnect Voltage(LVD), the controller stops discharging the battery to protect the battery from being over-discharged.
 Overload Protection The load is switched off after a delay when the load current exceeds 1.25 times the rated current. The user must reduce the load appliance, press the button, or restart the controller.
 Load Short Circuit Protection The load is switched off when the load short circuit (3 times the rated current) happens. The user must clear the short circuit faults, press the button, or restart the controller.
 High Voltage Transients Protection The controller is protected against small high voltage transients. In

Tel: +86-752-3889706

Website: www.epever.com

lightning-prone areas, an external lightning arrester is recommended.

8. Troubleshooting

Faults

Possible reasons

Troubleshooting

The charging LED

turns off during the daytime when sunshine falls on PV

PV array disconnection

Confirm that PV and battery wire connections are correct and tight.

modules properly.

Battery voltage

Measure battery voltage with

No LED indicator

may be less than the multi-meter. Min.8V can

8V

start up the controller.

Charging LED fast flashes.

Battery over voltage

Check if the battery voltage is higher than the OVD, and disconnect the PV.

The load will recover when the

LED1 fast flashes.

Battery over-discharged

battery voltage is restored to or above the LVR (low voltage

reconnect voltage).

 Please reduce the number

Load LED flashes slowly.

Overload

of electric equipment.  Press the button or restart

the controller.

 Check carefully loads

Load LED fast flashes.

Load short circuit

connection, clear the fault.  Press the button or restart

the controller. When the load current exceeds 1.25 times, 1.5 times, and 2 times the rated value, the controller can automatically turn off loads after 60s, 5s, and 1s, respectively.

10. Disclaimer

This warranty does not apply under the following conditions:  Damage from improper use or use in an unsuitable environment.  PV or load current, voltage, or power exceeds the controller's rated value.  User disassembly or attempted to repair the controller without permission.  The controller is damaged due to natural elements such as lighting.  The controller is damaged during transportation and shipment.

9. Technical Specifications

Item Nominal system voltage Rated charge current Rated discharge current Battery input voltage range Max. PV open circuit voltage Self-consumption Charge Circuit Voltage Drop Discharge Circuit Voltage Drop USB input interface Temperature compensation coefficient Environment temperature Humidity Enclosure Grounding
Dimension(L x W x H)
Mounting size Mounting hole size Terminals Net weight

LS0512E LS1012E LS1024E

LS2024E

12VDC

12/24VDC Auto

5A

10A

20A

5A

10A

20A

LS0512EU LS1012EU LS1024EU LS2024EU LS3024EU

12VDC

12/24VDC Auto

5A

10A

20A

30A

5A

10A

20A

30A

8V16V

8V32V

8V16V

8V32V

30V

50V

0.21V

30V 12V5mA; 24V7mA

50V 0.13V

0.12V --

0.17V 5VDC/1.2A

5VDC/2A

-5mV//2V

IP30

92.8x65 x20.2mm 84.4mm

101.2x67 x21.8mm 92.7mm

101.2x67 x21.8mm 92.7mm

14AWG/2.5mm2 12 AWG/4mm2 12AWG/4mm2

0.07kg

0.08kg

0.08kg

-35  +50

128x85.6 x34.8mm 118mm
10AWG/6mm2
0.15kg

95%,(N.C.)

IP20

Common Positive

109.7x65.5

120.3x67

120.3x67

148x85.6 148x106.8

x20.8mm

x21.8mm

x21.8mm

x34.8mm

X43.7mm

100.9mm

111.5mm

138mm

4.5

14AWG/2.5mm2 12AWG/4mm2 12AWG/4mm2 10AWG/6mm2 8AWG/10mm2

0.09kg

0.10kg

0.10kg

0.18kg

0.29kg

Any changes without prior notice! Version number: V4.2

3

4



References