AXL F BK PN TPS - Bus Coupler

Phoenix Contact

Item Number: 2403869

URL: https://www.phoenixcontact.com/us/products/2403869

This document provides technical specifications and product information for the Phoenix Contact AXL F BK PN TPS Bus Coupler. Data is sourced from the online catalog.

Product Description

The bus coupler is intended for use within a PROFINET network. It creates the link to the Axioline F I/O system and industrial I/O signals connected to it. Up to 63 Axioline F devices can be connected to the bus coupler. Device descriptions for Phoenix Contact controllers are integral parts of the engineering tools PC Worx and PLCnext Engineer. Corresponding GSDML files are available for integrating the Axioline F station into other programming systems.

Your Advantages

Commercial Data

Item numberPacking unitSales keyProduct keyCatalog pageGTINWeight per piece (including packing)Weight per piece (excluding packing)Customs tariff numberCountry of origin
24038691 pcDR02DRI21APage 69 (C-6-2019)4055626345826221.4 g220.8 g85176200DE

Technical Data

Dimensions

Image of the Axioline F Bus Coupler, showing its compact form factor with RJ45 connectors.

The device has a width of 45 mm, a height of 126.1 mm, and a depth of 74 mm. The depth measurement applies when a TH 35-7.5 DIN rail is used, in accordance with EN 60715.

Notes

Utilization restrictionEMC note
EMC: class A product, see manufacturer's declaration in the download area

Interfaces

PROFINET
Number of interfaces2
Connection methodRJ45 jack
Note on the connection methodAuto negotiation and autocrossing
Transmission speed100 Mbps (full duplex)
Transmission physicsEthernet in RJ45 twisted pair
Axioline F local bus
Number of interfaces1
Connection methodBus base module
Transmission speed100 Mbps
Service
Number of interfaces1
Connection methodUSB type C

System Properties

System limits
Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 63

Device Function & Properties

Device functionPROFINET device
SpecificationVersion 2.3
Conformance ClassConformance-Class C
Device ID1000 hex
Vendor ID00B0 hex
TypeBlock modular
Product typeI/O component
Product familyAxioline F
Mounting positionany (observe temperature derating)
Scope of deliveryincluding bus base module and Axioline F connector

Insulation Characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical Properties

Maximum power dissipation for nominal conditionmax. 2.5 W
Potentials: Communications power UL feed-in
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 600 mA (2.0 A at UBus, UL = 24 V, up to HW 03)
max. 700 mA (2.5 A at UBus, UL = 24 V, from HW 04)
Power consumptionmax. 14.4 W (2.0 A at UBus, UL = 24 V, up to HW 03)
max. 16.8 W (2.5 A at UBus, UL = 24 V, from HW 04)
Protective circuitSurge protection; electronic
Reverse polarity protectionno
Potentials: Axioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Power supply unitmax. 2 A (up to HW 03)
max. 2.5 A (As of HW 04)
Electrical isolation/isolation of the voltage ranges
Test voltage: PROFINET interface 1 / PROFINET interface 21500 V AC, 50 Hz, 1 min.
Test voltage: PROFINET interface 1 / 24 V communications voltage (UL) feed-in1500 V AC, 50 Hz, 1 min.
Test voltage: PROFINET interface 2 / 24 V communications voltage (UL) feed-in1500 V AC, 50 Hz, 1 min.
Test voltage: PROFINET interface 1 / functional ground1500 V AC, 50 Hz, 1 min.
Test voltage: PROFINET interface 2 / functional ground1500 V AC, 50 Hz, 1 min.
Test voltage: 24 V communications voltage (UL) feed-in / functional ground500 V AC, 50 Hz, 1 min.

Connection Technology

Axioline F connector
Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the "Axioline F: system and installation" user manual.
Conductor connection
Connection methodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm
Axioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the "Axioline F: system and installation" user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Environmental and Real-life Conditions

Ambient conditionsValues
Ambient temperature (operation)-25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail)
-25 °C ... 55 °C (Mounting position: any)
Degree of protectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting typeDIN rail mounting
Mounting positionany (observe temperature derating)

Diagrams

Connection of the cables: Diagram showing the physical connections. It illustrates Ethernet ports (X1, X2) and a 24 V DC power input (UL). Status LEDs (BF, SF, RDY, DE) are also indicated.

Dimensional drawing: The device has a width of 45 mm, a height of 126.1 mm, and a depth of 74 mm.

Block diagram: Functional block diagram illustrating the internal architecture. It shows two Ethernet interfaces, a central microcontroller (µC), LEDs for status indication, power inputs (UL 24V, UBus 3.3V), and the connection to the local bus (UBus). Reset and Service interfaces are also depicted.

Approvals

To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/2403869

  • DNV GL (Approval ID: TAA00000DF)
  • LR (Approval ID: LR2001902TA-08)
  • ClassNK (Approval ID: 14A006)
  • BV (Approval ID: 36433/B4 BV)
  • PRS (Approval ID: TE/1020/880590/21)
  • BSH (Approval ID: 840)
  • RINA (Approval ID: ELE008423XG)
  • ABS (Approval ID: 20-2059154-PDA)
  • PROFINET (Approval ID: Z12930)
  • UAE-RoHS (Approval ID: 23-02-63241)
  • cULus Listed (Approval ID: E238705)

Classifications

Classification SystemCode
ECLASS-11.027242608
ECLASS-12.027242608
ECLASS-13.027242608
ETIM 9.0EC001604
UNSPSC 21.032151600

Environmental Product Compliance

REACH SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years. For information on hazardous substances, refer to the manufacturer's declaration available under "Downloads".

Accessories

  • AXL F BS BK - Bus connector (2701422): Axioline F bus base module for housing type BK. Link
  • FL PLUG RJ45 GR/2 - RJ45 connector (2744856): RJ45 connector, degree of protection: IP20, 8 positions, 1 Gbps, CAT5, Crimp connection, AWG 26-24, straight outlet, gray. Link
  • FL PLUG RJ45 GN/2 - RJ45 connector (2744571): RJ45 connector, degree of protection: IP20, 8 positions, 1 Gbps, CAT5, Crimp connection, AWG 26-24, straight outlet, green. Link
  • FL CAT5 HEAVY - Data cable (2744814): CAT5-SF/UTP cable, heavy-duty installation cable, 2 x 2 x 0.22 mm², shielded, outer sheath: 7.8 mm diameter. Link
  • FL CAT5 FLEX - Installation cable (2744830): Installation cable, Ethernet CAT5 (100 Mbps), shielded, PUR halogen-free, water blue RAL 5021, 4-wire. Link
  • FL CRIMPTOOL - Assembly tool (2744869): Crimping pliers for assembling RJ45 plugs. Link
  • ZB 20,3 AXL UNPRINTED - Zack marker strip (0829579): Zack marker strip for Axioline F device labeling, unprinted, 25-section. Link
  • ZBF 10/5,8 AXL UNPRINTED - Zack Marker strip, flat (0829580): Flat Zack Marker strip, white, unlabeled, for terminal block width 10.15 mm. Link
  • EMT (35X18,7)R - Insert label (0801831): Insert label for marking Phoenix Contact Axioline modules, roll, white, unlabeled. Link
  • SAFE AI - Function block (2400057): Function block library for safety-related analog value acquisition. Contact safety hotline (+49 5281 9-462777) before ordering. Link
  • CAB-USB A/ USB C/1,8M - Connecting cable (2404677): Connecting cable from USB A to USB C for controller-PC connection. Link
  • CAB-USB C/ USB C/1,8M - Connecting cable (1021809): Connecting cable from USB C to USB C for controller-PC connection. Link

Phoenix Contact 2024 - all rights reserved

Models: 2403869 AXL F BK PN TPS Bus Coupler, 2403869, AXL F BK PN TPS Bus Coupler, Bus Coupler, Coupler

File Info : application/pdf, 16 Pages, 628.82KB

PDF preview unavailable. Download the PDF instead.

phoenix-contact-2403869-en

References

iText Core 7.2.5 (production version), pdfHTML 4.0.5 (production version) ©2000-2023 iText Group NV,

Related Documents

Preview Phoenix Contact PLCnext Technology: Controllers, I/O Systems, and Software
Explore Phoenix Contact's PLCnext technology, featuring advanced PLC controllers, versatile Axioline I/O systems (F, SE, E), and powerful engineering software for industrial automation. Discover open architecture, multi-language programming, and extensive communication protocols.
Preview Phoenix Contact IL MOD BK DI8 DO4-PAC Inline Bus Coupler Datasheet
Technical datasheet for the Phoenix Contact IL MOD BK DI8 DO4-PAC Inline Bus Coupler, detailing its features, specifications, Modbus/RTU communication, digital I/O, parameterization, and safety information for explosive areas.
Preview Guia Técnico: Comunicação OPC UA entre Node-RED e PLCnext
Este guia técnico da PHOENIX CONTACT detalha a configuração e implementação da comunicação OPC UA entre o software Node-RED e o sistema PLCnext. Abrange desde a instalação do Node-RED e configuração do servidor OPC UA no PLCnext até a configuração de nós OPC UA Client no Node-RED para leitura e escrita de variáveis.
Preview Guia de Configuração do Node-RED no PLCnext | Phoenix Contact
Aprenda a configurar e integrar o Node-RED com controladores PLCnext da Phoenix Contact para automação industrial, IoT e edge computing. Guia técnico detalhado.
Preview Technical Guide: PLCnext and Compactlogix Communication via Node-RED
Learn how to integrate PHOENIX CONTACT PLCnext and Allen Bradley Compactlogix controllers using Node-RED for industrial automation. This guide covers configuration, variable reading, and writing.
Preview PLCnext and S7-1200 Communication via Node-Red: Technical Guide
A technical guide from PHOENIX CONTACT detailing the setup and configuration for communication between PLCnext controllers and Siemens S7-1200 PLCs using Node-Red, including Tia Portal and Node-Red configurations.
Preview Phoenix Contact Product Certification Certificate - AXC F XT ETH 1TX and AXL Series
This document contains the China Compulsory Certification (CCC) for Phoenix Contact products, specifically the AXC F XT ETH 1TX and AXL series. It details model numbers, technical specifications, electrical parameters, and environmental operating conditions, including explosion protection markings.
Preview Phoenix Contact INTERBUS Diagnostics Guide for Generation 4 Controller Boards
Comprehensive guide to diagnosing INTERBUS systems, detailing diagnostic displays, LED indicators, error codes, menu navigation, and troubleshooting for Phoenix Contact Generation 4 controller boards.