AERIC DEHUMIDIFIER

USER'S MANUAL

Model: AERD351P

Important Safety Introductions

Inside you will find many helpful tips on how to use and maintain your dehumidifier properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your dehumidifier. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.

To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications:

[Warning Symbol] WARNING This symbol indicates the possibility of death or serious injury.

[Caution Symbol] CAUTION This symbol indicates the possibility of injury or damage to property.

[Prohibited Action Symbol] Never do this.

[Required Action Symbol] Always do this.

WARNING

CAUTION

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The appliance shall be installed in accordance with national wiring regulations. Do not operate your dehumidifier in a wet room such as a bathroom or laundry room. The appliance with electric heater shall have at least 2 feet space to the combustible materials. Contact the authorised service technician for repair or maintenance of this unit.

WARNING

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your dehumidifier, follow basic precautions, including the following:

Electrical Information

The complete electrical rating of your new dehumidifier is stated on the serial plate. Refer to the rating when checking the electrical requirements.

Grounding type wall receptacle

Diagram description: A standard wall receptacle with a grounding slot. Text next to it reads: "Do not, under any circumstances, cut, remove, or bypass the grounding prong."

Power supply cord with 3-prong grounding plug and current detection device

PLACEMENT

At least 7.9 inches (20 cm) air space between front/rear/left/right sides of dehumidifier and adjacent obstacle and at least 24 inches (61 cm) air space between top side of dehumidifier and adjacent obstacle should be maintained during normal operation.

WARNING

WARNING

SPECIFICATIONS

Figures noted, in the contents are for reference only; variation may result due to application in different countries or regions, and shall be based on the best of practical operation.

Voltage/FrequencyAC 115V~60Hz
Refrigerant TypeR32
Working Temperature41°F - 89.6°F (5°C - 32°C)
Working Humidity30% - 90%RH

NOTE Wiring diagram affixed inside the rear panel

NOTE Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

WARNING (FOR USING R32 REFRIGERANT ONLY)

READ THE MANUAL CAREFULLY BEFORE USING THE APPLIANCE.

Explanation of symbols displayed on the unit (For the unit adopts R32 Refrigerant only)

WARNING (FOR USING R32 REFRIGERANT ONLY)

  1. Transport of equipment containing flammable refrigerants See transport regulations.
  2. Marking of equipment using signs See local regulations.
  3. Disposal of equipment using flammable refrigerants See national regulations.
  4. Storage of equipment/appliances The storage of equipment should be in accordance with the manufacturer's instructions.
  5. Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
  6. Information on servicing
    1. Checks to the area: Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
    2. Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapour being present while the work is being performed.
    3. General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
    4. Checking for presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
    5. Presence of fire extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
    6. No ignition sources: No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
    7. Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
    8. Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:
      • The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
      • The ventilation machinery and outlets are operating adequately and are not obstructed;
      • If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
      • Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
      • Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
    9. Checks to electrical devices: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include:
      • That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
      • That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
      • That there is continuity of grounding.
  7. Repairs to sealed components
    1. During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
    2. Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
      • Ensure that apparatus is mounted securely.
      • Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres.
      • Replacement parts shall be in accordance with the manufacturer's specifications.

    NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.

  8. Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
  9. Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
  10. Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
  11. Leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
  12. Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. Opening of the refrigeration systems shall not be done by brazing. The following procedure shall be adhered to:
    • Remove refrigerant;
    • Purge the circuit with inert gas;
    • Evacuate;
    • Purge again with inert gas;
    • Open the circuit by cutting or brazing.
    The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
  13. Charging procedures In addition to conventional charging procedures, the following requirements shall be followed.
    • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
    • Cylinders shall be kept upright.
    • Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
    • Label the system when charging is complete (if not already).
    • Extreme care shall be taken not to overfill the refrigeration system.
    • Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
  14. Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task 's commenced.
    1. Become familiar with the equipment and its operation.
    2. Isolate system electrically.
    3. Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders; All personal protective equipment is available and being used correctly; The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards.
    4. Pump down refrigerant system, if possible.
    5. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
    6. Make sure that cylinder is situated on the scales before recovery takes place.
    7. Start the recovery machine and operate in accordance with manufacturer's instructions.
    8. Do not overfill cylinders. (No more than 80 % volume liquid charge).
    9. Do not exceed the maximum working pressure of the cylinder, even temporarily.
    10. When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
    11. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
  15. Labelling Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
  16. Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

NOTE: The following precautions are for the recovery of refrigerant. Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

Identification of Parts

Diagram description: The dehumidifier unit features a dry air vent and control panel at the top, a handle for carrying, and a drain water tank at the front base. The moist air intake is located on the side, with an air filter behind it. A continuous drainage outlet is also present, and the unit stands on roll castors.

Function Explanation

Control Panel

Buttons: POWER, MODE, SPEED, TIMER/HUMIDITY SET (+/-), TIMER, FILTER RESET, DISPLAY.

Indicator Lights: Defrost, Bucket Full, Dehumidification, Continuous, High Fan, Low Fan, Timer On/Off, Display, Clean Filter.

Display

Shows current humidity (%) or Time Delay hours. The corresponding indicator light will illuminate.

Power Button

Turns the unit ON/OFF. Note: does not disconnect from power supply.

Mode Control Button

Two settings: Dehumidification, Continuous. The settings are adjusted with the Mode Control button. A light will indicate which setting is currently being used.

Fan Speed Button

Two settings: High, Low. Press the Fan Speed button to toggle among the two speeds. The corresponding fan speed indicator will illuminate.

Timer

Programs auto-off (1-24 hours) or auto-on. When a Time Delay is programmed, the Timer indicator light will illuminate.

Humidity/Timer Set Buttons (+ and -)

Adjusts the Humidity or Hours in Time Delay.

To Set the Humidity Level: The humidity can be set between 30% RH and 90% RH. The humidity can be adjusted in increments / decrease of 5% by each press of a button. Press the +/- buttons to select the desired Relative Humidity (RH). Note: After setting the humidity level, the display will revert to the current humidity after a few seconds have passed.

Filter Reset Button

After 250 hours of operation, the indicator light will glow to remind you to clean the filter. Remove the filter and clean it. Press Filter reset button to turn off the light and Reset the filter alarm. See "AIR FILTER CLEANING STEPS".

Light Switch Button

Turns top panel lights on/off.

Bucket Full

Indicator illuminates when the water collection bucket is full.

Defrost

Indicator illuminates when the unit enters defrost mode due to low room temperature. The unit will operate in temperatures down to 41°F (5°C). Do not use below 41°F (5°C).

NOTE: When operating the dehumidifier for extended periods (greater than 12 hours continuously) the dehumidifier will operate for 12 hours on then 1 hour off in order to reset the system. During the off period, "SA" will show in the display window for 3 seconds when pressing the button, and then resume to the settings. The unit will restart automatically after the hour is complete.

Operating Instructions

Start Operation

  1. Insert plug into a suitable wall socket matching the rating label voltage.
  2. Remove the complimentary direct drainage hose from the front tank. Ensure the water tank is properly inserted. If "Bucket Full" indicator illuminates, check the float lever movement and reinsert the tank.

When Water Tank Full Lamp is On

The machine stops, "Water tank Full" light illuminates. Remove the tank carefully, empty it, and replace it properly to resume operation.

Defrost

Unit enters defrost mode automatically in low temperatures (below 53.6°F / 12°C) to prevent frost buildup on the evaporator. Defrost lamp comes on. Unit operates down to 41°F (5°C). Do not use below 41°F (5°C).

Continuous Drainage

Steps:

  1. Prepare hose.
  2. Remove drain cover from drainage outlet.
  3. Remove soft rubber stopper from drain cover and store it.
  4. Thread hose through drain cover.
  5. Connect hose to drain port.
  6. Screw drain cover back to drainage outlet.
  7. Place bucket in original location (optional, for backup).

Proper Way to Place Hose

Hose must be placed below the drainage hole. Avoid uneven surfaces and do not kink the hose. (Diagram description: Shows correct vs. incorrect hose placement with X marks).

Maintenance

Ensure dehumidifier is unplugged before servicing/cleaning.

Clean the Shell

  1. Wipe with a soft, clean cloth.
  2. For dirtier units, use mild detergent and a half-dried cloth.
  3. Do not wash with a hose due to electrical hazard.

Clean the Air Filter

Purpose: Filters dust/particles, protects inner components. Blockage: Increases electricity usage, risk of overheating. Frequency: Clean at least every two weeks. Do not use in dusty environments.

Cleaning Steps:

  1. Pull out the filter gently.
  2. Clean by vacuum cleaner or washing with clean water, then dry with a dry cloth.
  3. Place the filter back.

Troubleshooting Guide

ProblemPossible CausesSolution
Dehumidifier doesn't workElectricity shutdown or low voltage
Bad plug or a wire is broken
Connect the appliance to the correct supply source
Contact customer service to repair or replace*
Fan doesn't workMotor is broken
Low voltage
Contact customer service to repair or replace*
Connect the appliance to the correct supply source
Compressor doesn't workStill under the 3 min. compressor reset protection
Compressor is broken
Wait until it goes back to function after 3 min.
Contact customer service to repair or replace*
Can not dehumidify or the dehumidification volume is too lowFilter is dirty
Refrigerant is leaking
Low temp. and humidity
Uneven floor
Clean filter
Detect the leakage and fill with refrigerant.*
Normal
Place the appliance on a flat, stable, heat-resistant surface.
Loud noise and vibrationMotor or compressor is loose
Sound of flowing water
Tighten screws
Normal, it is the sound when the refrigerant is flowing
Evaporator is frostedFilter is too dirty
environment temp. is too low
Clean filter
Stop use temporarily
Dehumidification water overflowsDrain bucket could be broken broken
Micro switch could be broken broken
Contact customer service to repair or replace*
Contact customer service to repair or replace*
The water tank full lamp onThe water tank is full
The water tank is not correctly installed
Pour the water and reposition the water tank correctly
Reposition the water tank correctly
LED display "E1"The temperature sensor is open or short circuit.Contact customer service to repair or replace*
LED display "E2"The tube sensor is open or short circuit.Contact customer service to repair or replace*

Caution: Do not attempt to repair, disassemble or modify the appliance. There are no user-serviceable parts inside. We suggest you to contact your service agent or a professional electrician for any help.

Warranty

Limited Carry-in Appliance Warranty

This product is warranted to be free from manufacturer's defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. The warranty is available only to the person to whom the unit was originally sold by manufacturer or by an authorized distributor of manufacturer and is non-transferable.

Terms of Warranty

Plastic parts are warranted for thirty (30) days from purchase date with no extensions provided.

FIRST 24 Months: During the first twenty-four (24) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrintor's option,at no charge to the ORIGINAL purchaser. Please keep your purchase receipt as a warranty proof of purchase date.

To Obtain Service:

Contact information: Tel: 888-984-2766, Email: service@aeric.com. Return to the store WHERE PURCHASED FOR REPLACEMENT.

Exclusions

Save as herein provided by manufacturer, there are no other warranties, conditions, representations or other warranties, conditions express or implied, made or intended by manufacturer or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or status is hereby expressly excluded. Save as herein provided, manufacturer shall not be responsible for any damage or loss of users, except as expressed or for any consequential loss arising from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless manufacturer from any claim for damages to persons or property caused by the unit. As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow limitation or implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from state to state.

General Provisions

  1. No warranty in insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
  2. Power failure.
  3. Damage in transit or when moving the appliance.
  4. Improper power supply such as low voltage, defective house wiring or inadequate fuses.
  5. Accident, attention, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions (extremely high or low room temperatures).
  6. Use in commercial or industrial purposes (i.e. the appliance is not installed in a domestic residence).
  7. Fire, water, damage, theft, war, riot, hostility, acts of God such as hurricanes, floods, etc.
  8. Service calls resulting in customer education.

Manufacturer: AERIC LLC, Ramsey New Jersey 07446 USA.

Models: AERD351P 3 Speed Dehumidifier, AERD351P, 3 Speed Dehumidifier, Dehumidifier

PDF preview unavailable. Download the PDF instead.

bSLQQ5JuTdZdFNG9OeesysXx9V7cbpx5loAXl77I

Related Documents

Preview AERIC AERP051AW Portable Air Conditioner User Manual
Comprehensive user manual for the AERIC AERP051AW portable air conditioner, covering safety instructions, parts identification, operation, installation, troubleshooting, care, maintenance, and warranty information.
Preview AERIC AERD501PF Dehumidifier User Manual: Safety, Operation, and Troubleshooting
Comprehensive user manual for the AERIC AERD501PF dehumidifier, covering important safety instructions, parts identification, function explanation, operating procedures, maintenance, troubleshooting, and warranty information.
Preview Aeric Portable Air Conditioner User's Manual - AERP051AW
User's manual for the Aeric Portable Air Conditioner, model AERP051AW. This guide provides important safety instructions, identification of parts, operation details, installation instructions, troubleshooting tips, care and maintenance guidelines, and warranty information.
Preview AERIC AERD501PF Dehumidifier - Features and Specifications
Discover the AERIC AERD501PF Dehumidifier, designed for efficient home comfort. This unit offers a 50-pint daily dehumidifying capacity, a large 16.2-pint bucket, a washable removable filter, and a programmable 1-24 hour timer. It operates within a temperature range of 41-89.6°F and features a 2-year limited warranty. Includes a 6-ft. power cord and a noise level of 50 dBA (Max). ENERGY STAR certified.
Preview Aeric AERD501P Dehumidifier: Features and Specifications
Detailed specifications and features of the Aeric AERD501P dehumidifier, including its dehumidifying capacity, bucket capacity, operating temperature, and warranty.
Preview Aeric AERP051AMW Portable Air Conditioner User's Manual
User's manual for the Aeric AERP051AMW portable air conditioner. Provides important safety instructions, parts identification, operation guidelines, and troubleshooting tips for optimal use and maintenance.
Preview AERIC AERP051AMW Portable Air Conditioner - Specifications and Features
Detailed specifications and features for the AERIC AERP051AMW portable air conditioner, including cooling capacity, dehumidification, airflow, noise level, and warranty information.
Preview Aeric AERP101HAW Portable Air Conditioner - Features and Specifications
Detailed information on the Aeric AERP101HAW portable air conditioner, including cooling capacity, features like dehumidification, heating, adjustable thermostat, programmable timer, noise level, and warranty.