Thermokon RDF-IR (LCD) RS485 Modbus
Surface Temperature Sensor
Application
The RDF-IR (LCD) is a flush-mounted sensor for surface temperature measurement in living spaces and offices. It utilizes infrared measurement to determine the average temperature over a circular detection area (optical detection range 80 ±5°). This allows for direct measurement of the surface temperature within the sensor's line of sight. When two IR sensors are used, the system can output individual temperatures or the average, minimum, or maximum value of both temperature signals, configurable via the Thermokon USEapp.
Type Overview
Flush-mounted temperature sensor with optional display - active BUS
- RDF-IR (LCD) RS485 Modbus
Safety Information - Attention
Warning: Installation and mounting of electrical devices (modules) must be performed by an authorized electrician. The device is intended for its designated use only. Unauthorized modification or alteration is prohibited. The modules must not be used in conjunction with devices that directly or indirectly serve human, health, or life-saving purposes, or whose operation could pose risks to people, animals, or property. Connection of devices with a power plug must only be done after the connection line has been de-energized!
Furthermore, the following apply:
- Laws, standards, and regulations
- The state of the art at the time of installation
- The technical data and the operating manual of the device
Disposal Information
The symbol of the crossed-out garbage bin indicates that the product or removable batteries must not be disposed of with household or commercial waste. Within the EU, you are legally obligated to dispose of the product separately and appropriately according to your country's national laws. Alternatively, contact your supplier or Thermokon Sensortechnik GmbH. Further information can be found at: www.thermokon.de
Product Testing and Certification
CE Conformity Declaration: Declarations of conformity for the products can be found on our website: https://www.thermokon.de/direct/categories/rdf-ir
Technical Data
Measurement Variables | Surface Temperature |
---|---|
Output Voltage | 1x/2x 0..10 V or 0..5 V (adjustable via jumper; live-zero configuration via Thermokon USEapp), min. load 10 kΩ |
Network Technology | RS485 Modbus, RTU, Half-duplex, Baud rate 9,600, 19,200, 38,400 or 57,600, Parity: None (2 stop bits), Even or Odd (1 stop bit) |
Voltage Supply | 15..35 V = or 19..29 V ~ SELV. For AC voltage, ensure correct polarity. |
Power Consumption | typ. 0.6 W (24 V =) | 1.5 VA (24 V ~) |
Output Signal Range *Scaling Analog Output | 0..+50 °C (default setting). Selectable from 4 temperature ranges: -40..+60 °C | 0..+50 °C | -20..+80 °C | -15..+35 °C, adjustable on the transducer. |
Temperature Operating Range *Max. Permissible Operating Temperature | -20..+70 °C |
Temperature Accuracy | ±0.5 K (typ. at 21 °C in the default measurement range). Mounting height max. 7 m, > 7 m ± 1.5 K |
Sensor | PIR (passive infrared), optical opening angle (50% sensitivity): 80 ±5°. Emissivity 1.0, other values upon request. |
Display (optional) | LCD 29x35 mm with RGB backlight |
Housing | USE-M housing, PC, pure white, with removable cable entry, LCD: Cover PC transparent |
Protection Class | IP30 according to DIN EN 60529 |
Cable Entry | M25 with 4-way cable entry for cables with max. Ø=7 mm, removable |
Electrical Connection | Removable plug-in terminal, max. 2.5 mm², sensor cable length=1.5 m (standard), max. 10 m, RJ45 connector |
Environmental Conditions | max. 85% RH, non-condensing |
Environmental Conditions Note: When multiple bus devices are powered by a 24V AC supply, ensure that all positive (+) operating voltage inputs of the field devices are connected together, and all negative (-) operating voltage inputs = reference potential are connected together (phase-synchronous connection of field devices). Reverse polarity of the supply voltage on one of the field devices will create a short circuit of the supply voltage through that device. The resulting short-circuit current flowing through this field device will cause damage. Therefore, pay attention to correct wiring.
Configuration
For communication between USEapp and USE-M/USE-L products, the Thermokon Bluetooth Dongle with Micro-USB is required (Art. No.: 668262). Commercially available Bluetooth dongles are not compatible.
Application-specific reconfiguration of the devices can be performed using the Thermokon USEapp. Configuration is done when the device is powered. The configuration app and its instructions can be downloaded from the Google Play Store or the Apple App Store.
App Stores:
User Notes
The Bluetooth Dongle clicks easily into the socket. When unplugging, please fix the plug-in card (option board) to prevent it from being accidentally pulled out.
The flush-mounted ceiling sensor is installed in a 26 mm diameter hole.
Application
RJ45 sockets
- Sensor 1 (Output Temperature 1)
- Sensor 2 (Output Temperature 2)
Base version expandable with a 2nd temperature sensor. Connection of 2 remote sensors is possible with a shielded RJ45 cable up to 10 m long!
Connection Plan
To switch the output voltage (0..10 V or 0..5 V) using jumpers, the display must first be removed from the circuit board. For daisy-chained RS485 cabling, connect both cable shields using the supplied 2-pole terminal as shown.
Voltage Output Selection:
- 0..5 V
- 0..10 V
Sensor 2 Connection:
- AO U2 Temperature 2* | 0..10 V
- AO U1 Temperature 1 | 0..10 V
Power Supply:
- PGND
- UB+
- -15..35 V = / 19..29 V ~
RS485 Cabling:
- A
- B
* Optional if Sensor 2 is connected.
DIP Switch Settings (Main Board)
DIP 1..3 Reserved* | Temperature Measurement Range – DIP 4 | 5 [SI / IMP] | Measurement Range – DIP 6 *Factory Settings | ||||
---|---|---|---|---|---|---|
OFF OFF* | OFF ON | ON OFF | ON ON | OFF* | ON | |
0..+50 | ||||||
+40..+140 | ||||||
-20..+80 | ||||||
-40..+60 | ||||||
-40..+160 | ||||||
-15..+35 °C | ||||||
0..+100 °F | ||||||
SI | ||||||
IMP |
DIP Switch Settings (Plug-on Board)
The Modbus address of the device is set via a 5-position DIP switch, binary coded in the range of 1...31. With address 0 via DIP, an extended address range (32..247) is available via USEapp.
Termination Resistor 120 Ω | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch 1 | Switch 2 | Baud Rate | Modbus Address | Parity | |||||||||
ON | ON | ON | ON | ON | ON | ON | ON | ON | ON | ON | *Factory Settings | ||
Activated | |||||||||||||
Deactivated* | |||||||||||||
9600* | |||||||||||||
19200 | |||||||||||||
38400 | |||||||||||||
57600 | |||||||||||||
Address Example: 26 | ON=2¹ (1)* | ON=2² (2) | ON=2³ (4) | ON=2⁴ (8) | ON=2⁵ (16) | ||||||||
Parity | |||||||||||||
Even | |||||||||||||
Odd | |||||||||||||
None (2 stop bits) | |||||||||||||
None* (1 stop bit) | |||||||||||||
None (1 stop bit) |
Modbus Addresses
USE-RS485 Modbus Interface. For a detailed description of the Modbus addresses, please visit the following link: https://www.thermokon.de/direct/files/use-rs485-modbus-manual.zip
Address | Access | Description | Register 400 = 1 (Unit SI) Resolution / Unit | Register 400 = 2 (Unit Imperial) Resolution / Unit |
---|---|---|---|---|
0 | R | Temperature 1 | 0.1 °C | Imperial 0.1 °F |
13 | R | Temperature 2 | 0.1 °C | Imperial 0.1 °F |
Dimensions (MM)
Diagram showing the dimensions of the sensor housing and its components.
Diagram Description:
- Main housing: 65 mm (length) x 85 mm (width) x 45 mm (height)
- Cable entry: 30 mm (length) x 28 mm (width) x 30.5 mm (height)
- Internal components: Various dimensions including 85 mm, 71 mm, 24 mm, 90 mm, 22 mm, 4.5 mm, 12 mm.
Accessories (Included in Delivery)
- Mounting base (Art. No.: 631228)
- Universal mounting set (Art. No.: 698511) - Includes cover screw + screw cover, 2 dowels, 2 countersunk screws, 2 lens head screws.
Accessories (Optional)
- Bluetooth Dongle (Art. No.: 668262)
- Cable entry M25 USE white, sealing insert 4x Ø=7 mm (Pack of 4) (Art. No.: 641364)
Related Documents
![]() |
Thermokon RDF-IR (LCD) RS485 Modbus Datasheet - Infrared Temperature Sensor Datasheet for the Thermokon RDF-IR (LCD) RS485 Modbus ceiling sensor, detailing its application, technical specifications, configuration, and dimensions for surface temperature measurement. |
![]() |
Thermokon RDF-IR (LCD) RS485 BACnet Datasheet - Ceiling Sensor Surface Temperature Datasheet for the Thermokon RDF-IR (LCD) RS485 BACnet ceiling sensor, providing technical specifications, application details, security advice, disposal notes, and configuration options for surface temperature measurement. |
![]() |
Thermokon RDF-IR Ceiling Surface Temperature Sensor Datasheet Datasheet for the Thermokon RDF-IR ceiling flush-mounted sensor, detailing its application, technical specifications, available types, and configuration options for surface temperature measurement. |
![]() |
Thermokon NOVOS 5 x (LCD) RS485 Modbus Room Operating Unit Datasheet Datasheet for the Thermokon NOVOS 5 x (LCD) RS485 Modbus room operating unit. This device measures temperature, humidity, CO2, and VOC, offering advanced features for indoor climate control in commercial and public spaces. Details include technical specifications, application notes, and configuration options via RS485 Modbus. |
![]() |
NOVOS 5 x (LCD) RS485 Modbus Raumbediengerät Datenblatt Technisches Datenblatt für das Thermokon NOVOS 5 x (LCD) RS485 Modbus Raumbediengerät. Erfassung von Temperatur, Feuchte, CO2 und VOC für Gebäudeautomation. |
![]() |
Thermokon NOVOS 3 (EPD) RS485 Modbus Room Sensor Datasheet Datasheet for the Thermokon NOVOS 3 (EPD) RS485 Modbus room sensor, detailing its application, available types, technical specifications, mounting instructions, connection plans, configuration options, display features, and DIP switch settings for temperature, humidity, CO2, and VOC monitoring. |
![]() |
Thermokon JOY HC AO2DO/HC 3AO RS485 Modbus Room Controller Datasheet Technical datasheet for the Thermokon JOY HC AO2DO and JOY HC 3AO room controllers, featuring RS485 Modbus communication. Details technical specifications, application, safety instructions, installation, and configuration. |
![]() |
Thermokon NOVOS 3 INC (EPD) RS485 Modbus Room Operating Unit Datasheet Technical datasheet for the Thermokon NOVOS 3 INC (EPD) RS485 Modbus room operating unit. This device measures temperature, humidity, CO2, and VOC, offering advanced control for HVAC systems via RS485 Modbus communication. |