Eastron SDM54 Series Smart Three Phase Energy Meter

User Manual

1. Introduction

The SDM54 measures and displays the characteristics of single-phase two-wire (1p2w) and three-phase four-wire (3p4w) supplies, including voltage, frequency, current, power, power factor, active and reactive energy, imported or exported. Energy is measured in terms of kWh and kVArh. Maximum demand on power and current can be measured over preset periods of up to 60 minutes. The SDM54 supports a maximum of 100A direct loads per phase, with dual tariff management availability. The meter is designed for DIN-rail mounting, with IP51 front protection. The meter is optionally equipped with pulse outputs, RS485 Modbus port, or M-bus port. Configuration can also be done via keypad, which is password protected.

1.1 Unit Characteristics

The SDM54 Series are smart three-phase energy meters, covering 3 models with the following features and differences:

Model Measurements Outputs Tariff Control
SDM54-2T kWh, kVarh, W, Var, VA, PF, Hz, V, A, Max.dmd. Etc. 2x Pulse outputs; RS485 Modbus Double tariffs
SDM54-M kWh, kVarh, W, Var, VA, PF, Hz, V, A, Max.dmd. Etc. 2x Pulse outputs; RS485 Modbus Single tariff
SDM54-DI kWh, kVarh, W, Var, VA, PF, Hz, V, A, Max.dmd. Etc. 2x Digital inputs; RS485 Modbus Single tariff
SDM54-MB-2T kWh, kVarh, W, Var, VA, PF, Hz, V, A, Max.dmd. Etc. 2x Pulse outputs; M-Bus Double tariffs
SDM54-MB kWh, kVarh, W, Var, VA, PF, Hz, V, A, Max.dmd. Etc. 2x Pulse outputs; M-Bus Single tariff
SDM54-P kWh, kVarh, W, Var, VA, PF, Hz, V, A, Max.dmd. Etc. 2x Pulse outputs Single tariff

1.2 RS485 Serial–Modbus RTU

The RS485 serial port with Modbus RTU protocol provides a means of remotely monitoring and controlling the unit. Set-up screens are provided for setting up the RS485 port. D/LT645 protocol is optionally available on request.

1.3 M-Bus

The M-Bus port complying with EN13757-3 protocol provides a means of remotely monitoring and controlling the meter. Set-up screens are provided for setting up the M-Bus port.

1.4 Pulse outputs

Two pulse outputs that clock up the measured active and reactive energy. The constant of pulse output 2 for active energy is 400imp/kWh (unconfigurable), its width is fixed at 100ms. The default constant of configurable pulse output 1 is 400imp/kWh, default pulse width is 100ms. The configurable pulse output 1 can be set from the set-up menu.

1.5 Double Tariffs

The meter has double tariffs function for cost allocation management. There are two terminals to monitor voltage input from an external device. Once voltage is detected within 230V (80~120%), the energy will be counted in another register.

2. Start-up Screens

The interface performs initial testing. The second screen indicates the software version. Meter serial number, Modbus ID, and Baudrate information are provided. After a short delay, the screen will display active energy measurements.

3. Measurements

Use the buttons to scroll the display for data-check or change options in Set-up mode. Press and hold a button to enter Set-up mode.

3.1 Buttons

There are two buttons on the front panel.

3.2 Measured parameters

Each successive pressing of the button shows different measured parameters:

4. Set-up

Password is needed before any further operation. The default password is 1000. The left screen shows the set-up menu of the meter, including main, communication, time, and pulse settings.

5. Specifications

5.1 Electrical specifications

5.2 Environmental specifications

5.3 Output specifications

Three interfaces are available:

5.3.1 Modbus RS485 port output

5.3.2 M-Bus port output

5.3.3 Pulse Output

The unit provides two pulse outputs indicating real-time measured energy. Pulse output 1 is configurable; Pulse output 2 is fixed with a constant of 400imp/kWh. Both pulse outputs are passive type. Pulse output 1 is configurable. Default setting is exp-kWh; 100mS, constant 400imp/kWh. Pulse output 2 is non-configurable. It is fixed with active kWh. The constant is 400imp/kWh.

5.4 Safety and EMC

5.5 Mechanics specifications

6. Dimensions

Diagram showing the dimensions of the SDM54 meter: Width 54mm, Height 105mm, Depth 67.5mm. The front panel height is 49.6mm.

7. Wiring diagram

Three Phase Four Wires: Diagram shows connections for L1, L2, L3, N, and outputs 1, 2, 3, 4, 5, 6.

Single Phase Two Wires: Diagram shows connections for L1, N, and outputs 1, 2, 3, 4.

Other terminals: Diagrams show terminal connections for different SDM54 models:

8. EU Declaration of Conformity

This section declares that the electricity meter types listed (SDM54-2T, SDM54M, SDM54-DI, SDM54-MB-2T, SDM54-MB, SDM54-P) with the measurement range 3 x 230/400V 50Hz, 0.5-10(100)A 400imp/kWh, are in conformity with the EU-type examination certificate 0120/SGS0533. The meters fulfill the essential requirements of Directive 2014/32/EU and standards EN50470-1:2006 and EN50470-3:2006. The declaration is issued by Zhejiang Eastron Electronic Co., LTD.

9. MID certificate

Details of the MID certificate (0120/SGS0533) issued by SGS Fimko OY for Zhejiang Eastron Electronic Co., Ltd. The certificate is valid until February 21, 2032.

Contact Us

For any questions, please contact Zhejiang Eastron Electronic Co., Ltd. at No. 1369, Chengnan Rd., Jiaxing, Zhejiang, 314001, China. Tel: +86-573-83698881, Fax: +86-573-83698883, Email: sales@eastrongroup.com, Website: www.eastrongroup.com.

Models: SDM54 Series, Smart Three Phase Energy Meter, SDM54 Series Smart Three Phase Energy Meter

File Info : application/pdf, 2 Pages, 1.09MB

PDF preview unavailable. Download the PDF instead.

Eastron SDM54 Manual V1. Apr22

References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Macintosh)

Related Documents

Preview Eastron Product Catalog: Energy Meters, Current Transformers, and Gateways
Explore the comprehensive range of Eastron's energy measurement solutions, including DIN-rail energy meters, current transformers (split core, solid core, Rogowski), and communication gateways for smart grid and IoT applications.
Preview Eastron SDM630 M-bus Series Smart Three Phase Energy Meter User Manual
User manual for the Eastron SDM630 M-bus series smart three-phase energy meter. Covers product introduction, technical parameters, operation, safety, accuracy, outputs, dimensions, wiring diagrams, and declarations of conformity.
Preview Eastron SDM630MCT V2 Series Multifunction Energy Meter User Manual
User manual for the Eastron SDM630MCT V2 Series multifunction energy meters, detailing installation, operation, setup, and specifications for single and three-phase electrical systems.
Preview EASTRON SDM630M CT-2T DIN Rail Smart Energy Meter User Manual
User manual for the EASTRON SDM630M CT-2T DIN Rail Smart Energy Meter, detailing its features, specifications, installation, and setup procedures for single and three-phase electrical systems. Covers measurements, communication, and operational settings.
Preview Eastron SDM230 Series User Manual: Single Phase DIN Rail Electricity Meter
User manual for the Eastron SDM230 series of single-phase, two-wire multifunction DIN rail electricity meters. Covers operation, specifications, installation, and wiring for models including Modbus, M-bus, Pulse, and 2T variants.
Preview Eastron SDM630MCT V2 Series Three Phase Multifunction Energy Meter User Manual
User manual for the Eastron SDM630MCT V2 Series multifunction energy meter, covering installation, operation, and setup procedures for single and three-phase electrical systems.
Preview Eastron SDM630MCT V2 Series Multifunction Energy Meter User Manual
Comprehensive user manual for the Eastron SDM630MCT V2 Series multifunction energy meters, covering installation, setup, specifications, and operation for single and three-phase electrical systems.
Preview Eastron SDM630MCT Series DIN Rail Three Phase Energy Meter Datasheet
Datasheet for the Eastron SDM630MCT Series DIN rail mounted three-phase energy meters, featuring MID certification, Modbus/Mbus communication, and detailed specifications for energy monitoring.