Owner's Manual for Kentec models including: KS-POWER-OUT, DS215-KS-POWER-OUT-Rev.01, KS-POWER-OUT System Wired Fire Detection, KS-POWER-OUT, System Wired Fire Detection, Wired Fire Detection, Fire Detection, Detection
K-System Wired Fire Detection - Kentec Electronics Ltd
Datasheets - Kentec Electronics Ltd
File Info : application/pdf, 2 Pages, 173.83KB
DocumentDocumentKS-POWER-OUT Powered Output Module Features Loop powered Single loop address programmed via TCH-B200 24 VDC output with adjustable current level 2 x Monitored inputs Compact design Colour coded flying leads for easy installation LPCB approved Description KS-POWER-OUT is an addressable Powered Output Module which allows ancillary equipment to be powered from the loop for example conventional beam detectors or flame detectors.. A Hochiki ESP protocol device it is compatible with Kentec's range of Taktis and Syncro addressable control panels. The module provides a 24 VDC output with an engineer configurable current level, current level can be set through the fire alarm control panel from 2-32mA in 2mA increments. This can be used to power a third party device. Two monitored inputs are provided for monitoring of outputs from the third party device to enable status to be indicated on the control panel i.e. Fire and Fault relays. KS-POWER-OUT requires a single loop address which is programmed using the TCH-B200 programmer. The compact design of the KS-POWER-OUT enables it to be installed within third party equipment. Specification Ordering Code and Description Operating Voltage Quiescent Current Alarm Current Test Signal Voltage Input Ratings Operating Temperature Range Storage Temperature Range Max Humidity Colour/Case Material Weight (g) Dimensions (mm) Approvals KS-POWER-OUT Powered Output Module 17 41 VDC 200 A (at 41 V) 2.3 ~ 32.3 mA 14 to 30 VDC Open Circuit >100 k Normal State ~10 k (EOL resistor provided) Input Activation ~470 (EOL resistor provided) Short Circuit <50 -10 °C to + 50 °C -30 °C to + 60 °C 95% RH - Non Condensing (at 40 °C) Ivory / ACS 30 65 L x 42 W x 19 D LPCB approved to EN54-18:2005 For further information visit www.kentec.co.uk KS-POWER-OUT panel configuration settings* The following table details the configuration options available on the Kentec Taktis and Syncro AS control panels: Configuration Options Configurable location text Fault Reporting Delay Map to zone Output Options Silenceable Invert output operation Configurable delay Drop on Reset (If output normally on) Current Limit Configurable Operating Duration Single Shot Mode Input Actions Input Action Message Bypass Output Delay Input Delay Latching or Non-Latching Invert input Disablement as a Plant Control Output Taktis Default ring mode (Fire), Evacuate Output, Alert Output, Pre Alarm Output, Technical Alarm Output Fault Output, Security Output Fire, Fault, Pre Alarm, Technical Alarm, Evacuate, Alert, Security, Silence, Reset, Transparent Disablement, Test Mode, Change sensitivity mode, Status, Acknowledge Alarm Extended Delay, Acknowledge Alarm Only, Override Delays Syncro AS/XT+ Default ring mode (Fire), Evacuate Output, Alert Output, Pre Alarm Output, Technical Alarm Output Fault Output, Security Output X X Fire, Fault, Pre Alarm, Technical Alarm, Evacuate, Alert, Security, Silence, Reset, Transparent Disablement, Test Mode X X * KS-POWER-OUT will be identified on Taktis and Syncro AS/XT+ control panels and on LE2 software as its Hochiki equivalent part number CHQ-POM. Datasheet DS215 06/24 Rev.01 For further information visit www.kentec.co.uk Kentec Electronics Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by Kentec Electronics Ltd. to be a complete and up-to-date description.