STC-200 Thermostat
Quick Start Guide
Version 21.08.02GEN
The STC-200+ thermostat with just one relay to control the power supply status of the wired heater or cooler or output alarm.
1. Wiring Diagram
A wiring diagram shows a 10A/220VAC input with terminals labeled 1 through 7. Terminal 1 is connected to the load (NC - Normally Closed). Terminals 4 and 5 are for the sensor. Terminals 6 and 7 are for the power supply (L - Line, N - Neutral).
2. Set the Aimed Temp Range
The aimed temperature range was defined from "SP" to "H"; hence you need to set both the "SP" and the "H" value.
3. Function Menu
Code | Function |
---|---|
F0 | Temperature Hysteresis / Difference |
F1 | Protection Delay Time for the Compressor |
F2 | Lower Limit for SP Setting |
F3 | Upper Limit for SP Setting |
F4 | Refrigeration or Heating or Alarm Mode |
F5 | Calibration = Real. - Measured. |
3.1. Set the "SP" value
- Press the Set key, shows the exists SP value.
- Press the ▲ or ▼ keys to change SP, which F2 and F3 limited.
- It will back to normal status from the setting interface in the 30s if without operation.
3.2. Set the "Hysteresis" Value?
- Hold the Set + ▲ keys simultaneously for 4s, and you will see the code F0.
- Next, press the Set key again to see the current value and press the direction key to change it.
- At last, press the Set key to save the new data and back to the menu list.
- Hold the Set key for 3s to saves data and back to normal monitor status.
- Repeat steps 2,3,4 to change others.
- Hold the Set key for 3s to quit from setting or leave it alone; it will back to normal status in the 30s if without operation.
This is not a step-by-step user manual; it just shows the key points. The new user should read the Full-Content Version User Manual.