INTERCOMS

Centurion Systems (Pty) Ltd www.centsys.com

Company Profile

1986
In-house R&D development team

1990

1995

1999

Today
Manufactures to international
quality standard ISO 9001:2015

ISO 9001:2015

After-sales multi-language Technical Support

100% testing of products

Sales and technical support to Africa, Europe, Asia, the Americas, Australia and the Pacific
Call Centre Operating Times Monday to Friday
08h00 to 17h00 GMT+2,
Saturdays 08h00 to 14h00 GMT+2
Centurion Systems (Pty) Ltd reserves the right to make changes to the product described in this manual without notice and without obligation to notify any persons of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd makes no representations or warranties with respect to this manual. No part of this document may be copied, stored in a retrieval system or transmitted in any form or by any means electronic, mechanical, optical or photographic, without the express prior written consent of Centurion Systems (Pty) Ltd.

Contents
1. INTRODUCTION 1.1. Technical Specifications

2. SPECIFICATIONS 2.1. Physical Dimensions 2.2. Technical Specifications

3. PRODUCT IDENTIFICATION 4. PHYSICAL INSTALLATION 4.1. Mounting the Metal Gate Station onto a Wall 4.2. Mounting the Metal Gate Station onto a Gooseneck

5. COMPLETING THE INSTALLATION

5.1. 5.1.1. 5.1.2. 5.1.2. 5.1.4.

Wiring a G-SPEAK ULTRA to the Metal Gate Station DX Controller D5ES Controller D-Series Controller VX SMART Controller

6. WARRANTY INFORMATION

Page 4 Page 4
Page 5 Page 5 Page 5
Page 6 Page 7 Page 7 Page 11
Page 12 Page 12
Page 12 Page 13 Page 14 Page 15
Page 16

Icons used in this manual
This icon indicates tips and other information that could be useful during the installation.

This icon denotes variations and other aspects that should be considered during installation.

This icon indicates warning, caution or attention! Please take special note of critical aspects that MUST be adhered to in order to prevent injury.

page 3

www.centsys.com

SECTION 1
1. INTRODUCTION
1.1. Important Safety Information

INTRODUCTION

ATTENTION!
To ensure the safety of people and possessions, it is important that you read all of the following instructions.
Incorrect installation or incorrect use of the product could cause serious harm.
Before handover to the end-user, the installer must ensure that the whole system is correctly installed and operates safely.

Warnings for the Installer
CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS before beginning to install the product.
· Do not in any way modify the components
· Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such materials are potential sources of danger
· Neither Centurion Systems (Pty) Ltd, nor its subsidiaries, accepts any liability caused by improper use of the product, or for use other than that for which the system was intended
· This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the service life/operation of the product and/or be a source of danger
· Anything not expressly specified in these instructions is not permitted

page 4

www.centsys.com

SECTION 2
2. SPECIFICATIONS
2.1. Physical Dimensions

SPECIFICATIONS

178mm

40mm

97mm

FIGURE 1. METAL GATE STATION PHYSICAL DIMENSIONS
2.2. Technical Specifications

METAL GATE STATION1

Operating voltage2

7.4V DC as supplied by the G-SPEAK ULTRA3

Current draw

11mA

Speech volume

Adjustable via G-WEB

Wiring

6 wire connection (power, audio and mic)

Ring tone

Electronic when button is depressed

Call confirmation

Yes

Call buttons

1, 2 or 4 (illuminated with labels)

Operating temperature

-20°C to +50°C

Humidity

0 - 90% non-condensing

Degree of protection

IP544

Dimensions

97mm wide x 40mm deep x 178mm high

TABLE 1

1. Requires a G-SPEAK ULTRA device, as the Gate Station cannot be used on its own. 2. If the 12V DC gate motor supply dips when the motor starts up and the intercom is being used at the same time,
the speech quality might be affected. 3. The Gate Station must only be powered via a G-SPEAK ULTRA Device. 4. A Gooseneck backing plate is required when mounting onto a Gooseneck, to maintain IP rating.

Please note that only the one- and two-button models of the Metal Gate Station are compatible with 2G, 3G, and 4G wireless technology. The four-button Metal Gate Station currently only allows for 4G compatibility.

page 5

www.centsys.com

SECTION 3
3. PRODUCT IDENTIFICATION
1

PRODUCT IDENTIFICATION 7

2

GOOSENECK BACKING PLATE KIT

3

4

6 5
11

10

8
1. Metal Gate Station Cover 2. Hex Socket Countersunk Screw 3. Hex Socket Cap Screw 4. Metal Gate Station PCB 5. Self Tapping Screw 6. Metal Gate Station Rear Housing

9
FIGURE 2. PRODUCT IDENTIFICATION
7. Wall Plug 8. M5x25 Cap Screw 9. Gooseneck Backing Plate 10. M5 Nyloc Nut 11. M5 Washer

page 6

www.centsys.com

SECTION 4
4. PHYSICAL INSTALLATION

PHYSICAL INSTALLATION

4.1. Mounting the Metal Gate Station onto a Wall

The following steps should only be performed once the G-SPEAK ULTRA has been successfully wired into your operator.

Hex Socket Countersunk Screw

1. Remove the four Hex Socket Countersunk Screws from the Metal Gate Station cover.

Metal Gate Station Cover

Metal Gate Station Cover

FIGURE 3

2. Remove the Metal Gate Station Cover away from the Metal Gate Station Rear Housing.

3. Remove the Hex Socket Cap Screw from the bottom of the Metal Gate Station PCB.

Hex Socket Cap Screw

page 7

Metal Gate Station Rear
Housing
FIGURE 4
Metal Gate Station PCB
FIGURE 5 www.centsys.com

SECTION 4

PHYSICAL INSTALLATION

4. Remove the Metal Gate Station PCB and internals by simultaneosuly pushing the top down while rotating the bottom towards you.

Metal Gate Station PCB

5. Once the Metal Gate Station

PCB has been removed, there

will be two points which you can

use to run your cables through,

to wire the Metal Gate Station

to your G-SPEAK ULTRA.

Ensure that the cables you

A

have pulled through are long

enough and that there is a

tight seal around your cables.

If not, use an industrial grade

silicone.
B

6. Place the Metal Gate Station

Rear Housing flat on the surface

where you would like to attach

C

the Metal Gate Station.

7. Using either points C and D or points C and E, mark and centre punch the hole positions for drilling.

8. Drill two 6mm holes.

Remove the Metal Gate

D

Station Rear Housing away

from the surface before

E

drilling.

page 8

Metal Gate Station Rear
Housing
FIGURE 6
POINT A

POINT B

FIGURE 7

POINT C

POINT D

POINT E
FIGURE 8 www.centsys.com

SECTION 4

9. Insert two Wall Plugs into the holes that you have drilled and fasten the Metal Gate Station Rear Housing to your flat surface using two Self Tapping Screws.

Self Tapping Screw

PHYSICAL INSTALLATION
Wall Plug Metal Gate Station Rear Housing
FIGURE 9

10. Wire your cables to the Wiring Block on the Metal Gate Station PCB and fit it back into the Metal Gate Station Rear Housing using the inverse movements of step 4.

Metal Gate Station PCB

Wiring Block

11.Fasten the Metal Gate Station PCB to the Metal Gate Station Rear Housing by replacing the Hex Socket Cap Screw at the bottom.

Mounting Bracket
Hex Socket Cap Screw

page 9

Metal Gate Station Rear
Housing
FIGURE 10
Metal Gate Station PCB
FIGURE 11 www.centsys.com

SECTION 4

PHYSICAL INSTALLATION

12.Remove a button cover off a Metal Gate Station button to expose the paper tag inside.
13.Write the relevant information on the paper tag and place it back inside the button cover.
14.Place the button cover back onto the Metal Gate Station button.
15.Repeat steps 12 to 14 on the rest of the buttons as necessary.

Buton Cover

View once the paper tag has a label written on it and is being placed back inside the button cover

16. Place the Metal Gate Station Cover back onto the Metal Gate Station Rear Housing and ensure that all components are propely clipped together.

Metal Gate Station Cover

Metal Gate Station
Button
FIGURE 12
Metal Gate Station Rear
Housing

17. Fasten the four Hex Socket Countersunk Screws on the Metal Gate Station cover to attach it onto the Metal Gate Station Rear Housing.

Hex Socket Countersunk Screw
Metal Gate Station Cover

FIGURE 13

page 10

FIGURE 14 www.centsys.com

SECTION 4

PHYSICAL INSTALLATION

4.2. Mounting the Metal Gate Station onto a Gooseneck

The following steps should only be performed once the G-SPEAK ULTRA has been successfully wired into your operator.

Hex Socket Countersunk Screw

Step 1 - 4 Refer to page 7 and 8 (follow step 1- 4).

Metal Gate Station Facsia

5. Run your cables from your Gooseneck through the Gooseneck Backing Plate and Metal Gate Station Rear Housing, to wire the Metal Gate Station to your G-SPEAK ULTRA.
Ensure that the cables you have pulled through are long enough and that there is a tight seal around your cables on the Metal Gate Station Rear Housing. If not, use an industrial grade silicone.

Gooseneck Backing Plate
Metal Gate Station Rear Housing

Metal Gate Station Rear Housing

6. Fasten the Metal Gate Station Rear Housing onto the Gooseneck Backing Plate and Gooseneck using two M5x25 Cap Screws.
Step 7 - 14 Refer to page 9 and 10 (follow step 10 - 17).

View once the Metal Gate Station Rear Housing and Gooseneck Backing Plate have been fastened onto the Gooseneck

page 11

FIGURE 15
Gooseneck
FIGURE 16
FIGURE 17 www.centsys.com

SECTION 5

COMPLETING THE INSTALLATION

5. COMPLETING THE INSTALLATION

5.1. Wiring a G-SPEAK ULTRA to the Metal Gate Station
5.1.1. DX Controller

G-SPEAK ULTRA

DX Control Card

GND IO1 IO2 IO3 IO4 P1 P2 P3 P4 P5 P6 VIN NEG

The I/Os are configured using MyCentsys Pro.
· I/O1 - TRG · I/O2 - PED · I/O4 - Gate Status · I/O5 - Alarm

P1 P2 P3 P4 P5 P6
page 12

Metal Gate Station FIGURE 18
www.centsys.com

SECTION 5
5.1.2. D5ES Controller
G-SPEAK ULTRA
GND IO1 IO2 IO3 IO4 P1 P2 P3 P4 P5 P6 VIN NEG

COMPLETING THE INSTALLATION D5ES Control Card

The I/Os are configured using MyCentsys Pro. · I1 - TRG · I2 - PED · I/O4 - Gate Status · I/O5 - Alarm
P1 P2 P3 P4 P5 P6
Metal Gate Station FIGURE 19

page 13

www.centsys.com

SECTION 5
5.1.3. D-Series Controller
G-SPEAK ULTRA

COMPLETING THE INSTALLATION
D-Series Control Card
Do not mount close to the DOSS sensor or remote receiver.

GND IO1 IO2 IO3 IO4 P1 P2 P3 P4 P5 P6 VIN NEG

P1 P2 P3 P4 P5 P6
page 14

Metal Gate Station FIGURE 20
www.centsys.com

SECTION 5
5.1.4. VX SMART Controller
G-SPEAK ULTRA

COMPLETING THE INSTALLATION
VX SMART Control Card
Do not mount close to the sensor wiring or remote receiver.

GND IO1 IO2 IO3 IO4 P1 P2 P3 P4 P5 P6 VIN NEG

The I/Os are configured using MyCentsys Pro.
· I1 - TRG · I2 - PED · I/O4 - Gate Status · I/O5 - Alarm

P1 P2 P3 P4 P5 P6
page 15

Metal Gate Station FIGURE 21
www.centsys.com

SECTION 6
6. WARRANTY INFORMATION

WARRANTY INFORMATION

You can register your product(s) online at www.centsys.com, which will assist you in keeping a record of your date of purchase or installation, serial numbers, etc.
All of our products are manufactured with extreme care, thoroughly inspected and tested.
The goods supplied by us shall be subject to the provisions of sections 55 to 57 of the Consumer Protection Act (68/2008) except where the provisions of the warranty contained in our product documentation are more favourable to the purchaser. Subject to the warranty contained in our product documentation, if applicable, our products are warranted for a period of twenty-four months after delivery. However, it is expressly noted that batteries carry a six month warranty due to the nature of these products being such that they are subject to possible misuse. Please note that warranties will be honoured on a carry-in basis; in other words, the product in question must be taken in to one of our branches, or to the authorised reseller that the product was purchased from, for assessment and, if necessary, repair. For equipment not of our manufacture, the warranty as supplied by the original manufacturer will apply if such warranty is more favourable to the purchaser than the relevant provisions of the Consumer Protection Act (Act 68/2008 of South Africa), or any other applicable law as so required in different countries in which the product was sold. Such warranty is valid only once full payment has been received for such goods.
Australian customers:
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure
Any warranty may be voidable on any equipment which:
1. Has not been installed in accordance with the installation instructions provided.
2. Has been subject to misuse or which has been used for any purpose other than that designed for by the manufacturers.
3. Has damage caused as a result of handling during transit, atmospheric conditions (including lightning), corrosion of metal parts, insect infestation, power surges or other forces outside of the control of the manufacturer.
4. Has been repaired by any workshop and / or person NOT previously authorised by the manufacturer.
5. Has been repaired with components not previously tested, passed or authorised by Centurion Systems (Pty) Ltd, South Africa or one of its subsidiary companies.

page 16

www.centsys.com

Notes

page 17

www.centsys.com

Notes

page 18

www.centsys.com

Notes

page 19

www.centsys.com

Connect with us on:

International Customers

Australian Customers

@CenturionSystemsRSA @Centurion.Systems @Centurion-Systems @CenturionSystems @Centurion.Systems @AskCenturion @Centurion.Systems Centurion-Systems

@FAACAustraliaPtyLtd @faac_australia_ @FAACAustralia @faacaustralia3920

Subscribe to the newsletter: www.centsys.com/subscribe

WhatsApp - Technical Support
South Africa:
+27 (0)83 650 4010
International:
+27 (0)83 650 4244

Call:
1 300 322 228 (FAAC Australia)
Email:
sales@faac.com.au
Technical Support Email:
technical.au@faactechnologies.com

Monday to Friday:
from 08h00 to 16h30 (GMT+2)
Saturday:
from 08h00 to 14h00 (GMT+2)

E&OE Centurion Systems (Pty) Ltd reserves the right to change any product without prior notice All product and brand names in this document that are accompanied by the ® symbol are registered trademarks
in South Africa and/or other countries, in favour of Centurion Systems (Pty) Ltd, South Africa.
The CENTURION and CENTSYS logos, all product and brand names in this document that are accompanied by the TM symbol are trademarks of Centurion Systems (Pty) Ltd, in South Africa and other territories; all rights are reserved. We invite you to contact us for further details.

ISO 9001:2015
Doc number: 1411.D.01.0001_25022025
www.centsys.com www.centsys.com.au



References

Adobe PDF Library 17.0 Adobe InDesign 19.3 (Windows)