Installation Guide for CENTSYS models including: G-SPEAK ULTRA, G-SPEAK ULTRA Metal Gate Station, Metal Gate Station, Gate Station, Station
4 days ago — Additionally, Centurion Systems (Pty) Ltd makes no representations or warranties with respect to this manual. No part of this document may be copied, stored in ...
3 giorni fa — To ensure the safety of people and possessions, it is important that you read all of the following instructions. Incorrect installation or incorrect use of the ...
File Info : application/pdf, 20 Pages, 1.40MB
DocumentDocumentMETAL GATE STATION INSTALLATION MANUAL INTERCOMS Centurion Systems (Pty) Ltd www.centsys.com Company Profile 1986 In-house R&D development team 1990 1995 1999 Today Manufactures to international quality standard ISO 9001:2015 ISO 9001:2015 After-sales multi-language Technical Support 100% testing of products Sales and technical support to Africa, Europe, Asia, the Americas, Australia and the Pacific Call Centre Operating Times Monday to Friday 08h00 to 17h00 GMT+2, Saturdays 08h00 to 14h00 GMT+2 Centurion Systems (Pty) Ltd reserves the right to make changes to the product described in this manual without notice and without obligation to notify any persons of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd makes no representations or warranties with respect to this manual. No part of this document may be copied, stored in a retrieval system or transmitted in any form or by any means electronic, mechanical, optical or photographic, without the express prior written consent of Centurion Systems (Pty) Ltd. Contents 1. INTRODUCTION 1.1. Technical Specifications 2. SPECIFICATIONS 2.1. Physical Dimensions 2.2. Technical Specifications 3. PRODUCT IDENTIFICATION 4. PHYSICAL INSTALLATION 4.1. Mounting the Metal Gate Station onto a Wall 4.2. Mounting the Metal Gate Station onto a Gooseneck 5. COMPLETING THE INSTALLATION 5.1. 5.1.1. 5.1.2. 5.1.2. 5.1.4. Wiring a G-SPEAK ULTRA to the Metal Gate Station DX Controller D5ES Controller D-Series Controller VX SMART Controller 6. WARRANTY INFORMATION Page 4 Page 4 Page 5 Page 5 Page 5 Page 6 Page 7 Page 7 Page 11 Page 12 Page 12 Page 12 Page 13 Page 14 Page 15 Page 16 Icons used in this manual This icon indicates tips and other information that could be useful during the installation. This icon denotes variations and other aspects that should be considered during installation. This icon indicates warning, caution or attention! Please take special note of critical aspects that MUST be adhered to in order to prevent injury. page 3 www.centsys.com SECTION 1 1. INTRODUCTION 1.1. Important Safety Information INTRODUCTION ATTENTION! To ensure the safety of people and possessions, it is important that you read all of the following instructions. Incorrect installation or incorrect use of the product could cause serious harm. Before handover to the end-user, the installer must ensure that the whole system is correctly installed and operates safely. Warnings for the Installer CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS before beginning to install the product. · Do not in any way modify the components · Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such materials are potential sources of danger · Neither Centurion Systems (Pty) Ltd, nor its subsidiaries, accepts any liability caused by improper use of the product, or for use other than that for which the system was intended · This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the service life/operation of the product and/or be a source of danger · Anything not expressly specified in these instructions is not permitted page 4 www.centsys.com SECTION 2 2. SPECIFICATIONS 2.1. Physical Dimensions SPECIFICATIONS 178mm 40mm 97mm FIGURE 1. METAL GATE STATION PHYSICAL DIMENSIONS 2.2. Technical Specifications METAL GATE STATION1 Operating voltage2 7.4V DC as supplied by the G-SPEAK ULTRA3 Current draw 11mA Speech volume Adjustable via G-WEB Wiring 6 wire connection (power, audio and mic) Ring tone Electronic when button is depressed Call confirmation Yes Call buttons 1, 2 or 4 (illuminated with labels) Operating temperature -20°C to +50°C Humidity 0 - 90% non-condensing Degree of protection IP544 Dimensions 97mm wide x 40mm deep x 178mm high TABLE 1 1. Requires a G-SPEAK ULTRA device, as the Gate Station cannot be used on its own. 2. If the 12V DC gate motor supply dips when the motor starts up and the intercom is being used at the same time, the speech quality might be affected. 3. The Gate Station must only be powered via a G-SPEAK ULTRA Device. 4. A Gooseneck backing plate is required when mounting onto a Gooseneck, to maintain IP rating. Please note that only the one- and two-button models of the Metal Gate Station are compatible with 2G, 3G, and 4G wireless technology. The four-button Metal Gate Station currently only allows for 4G compatibility. page 5 www.centsys.com SECTION 3 3. PRODUCT IDENTIFICATION 1 PRODUCT IDENTIFICATION 7 2 GOOSENECK BACKING PLATE KIT 3 4 6 5 11 10 8 1. Metal Gate Station Cover 2. Hex Socket Countersunk Screw 3. Hex Socket Cap Screw 4. Metal Gate Station PCB 5. Self Tapping Screw 6. Metal Gate Station Rear Housing 9 FIGURE 2. PRODUCT IDENTIFICATION 7. Wall Plug 8. M5x25 Cap Screw 9. Gooseneck Backing Plate 10. M5 Nyloc Nut 11. M5 Washer page 6 www.centsys.com SECTION 4 4. PHYSICAL INSTALLATION PHYSICAL INSTALLATION 4.1. Mounting the Metal Gate Station onto a Wall The following steps should only be performed once the G-SPEAK ULTRA has been successfully wired into your operator. Hex Socket Countersunk Screw 1. Remove the four Hex Socket Countersunk Screws from the Metal Gate Station cover. Metal Gate Station Cover Metal Gate Station Cover FIGURE 3 2. Remove the Metal Gate Station Cover away from the Metal Gate Station Rear Housing. 3. Remove the Hex Socket Cap Screw from the bottom of the Metal Gate Station PCB. Hex Socket Cap Screw page 7 Metal Gate Station Rear Housing FIGURE 4 Metal Gate Station PCB FIGURE 5 www.centsys.com SECTION 4 PHYSICAL INSTALLATION 4. Remove the Metal Gate Station PCB and internals by simultaneosuly pushing the top down while rotating the bottom towards you. Metal Gate Station PCB 5. Once the Metal Gate Station PCB has been removed, there will be two points which you can use to run your cables through, to wire the Metal Gate Station to your G-SPEAK ULTRA. Ensure that the cables you A have pulled through are long enough and that there is a tight seal around your cables. If not, use an industrial grade silicone. B 6. Place the Metal Gate Station Rear Housing flat on the surface where you would like to attach C the Metal Gate Station. 7. Using either points C and D or points C and E, mark and centre punch the hole positions for drilling. 8. Drill two 6mm holes. Remove the Metal Gate D Station Rear Housing away from the surface before E drilling. page 8 Metal Gate Station Rear Housing FIGURE 6 POINT A POINT B FIGURE 7 POINT C POINT D POINT E FIGURE 8 www.centsys.com SECTION 4 9. Insert two Wall Plugs into the holes that you have drilled and fasten the Metal Gate Station Rear Housing to your flat surface using two Self Tapping Screws. Self Tapping Screw PHYSICAL INSTALLATION Wall Plug Metal Gate Station Rear Housing FIGURE 9 10. Wire your cables to the Wiring Block on the Metal Gate Station PCB and fit it back into the Metal Gate Station Rear Housing using the inverse movements of step 4. Metal Gate Station PCB Wiring Block 11.Fasten the Metal Gate Station PCB to the Metal Gate Station Rear Housing by replacing the Hex Socket Cap Screw at the bottom. Mounting Bracket Hex Socket Cap Screw page 9 Metal Gate Station Rear Housing FIGURE 10 Metal Gate Station PCB FIGURE 11 www.centsys.com SECTION 4 PHYSICAL INSTALLATION 12.Remove a button cover off a Metal Gate Station button to expose the paper tag inside. 13.Write the relevant information on the paper tag and place it back inside the button cover. 14.Place the button cover back onto the Metal Gate Station button. 15.Repeat steps 12 to 14 on the rest of the buttons as necessary. Buton Cover View once the paper tag has a label written on it and is being placed back inside the button cover 16. Place the Metal Gate Station Cover back onto the Metal Gate Station Rear Housing and ensure that all components are propely clipped together. Metal Gate Station Cover Metal Gate Station Button FIGURE 12 Metal Gate Station Rear Housing 17. Fasten the four Hex Socket Countersunk Screws on the Metal Gate Station cover to attach it onto the Metal Gate Station Rear Housing. Hex Socket Countersunk Screw Metal Gate Station Cover FIGURE 13 page 10 FIGURE 14 www.centsys.com SECTION 4 PHYSICAL INSTALLATION 4.2. Mounting the Metal Gate Station onto a Gooseneck The following steps should only be performed once the G-SPEAK ULTRA has been successfully wired into your operator. Hex Socket Countersunk Screw Step 1 - 4 Refer to page 7 and 8 (follow step 1- 4). Metal Gate Station Facsia 5. Run your cables from your Gooseneck through the Gooseneck Backing Plate and Metal Gate Station Rear Housing, to wire the Metal Gate Station to your G-SPEAK ULTRA. Ensure that the cables you have pulled through are long enough and that there is a tight seal around your cables on the Metal Gate Station Rear Housing. If not, use an industrial grade silicone. Gooseneck Backing Plate Metal Gate Station Rear Housing Metal Gate Station Rear Housing 6. Fasten the Metal Gate Station Rear Housing onto the Gooseneck Backing Plate and Gooseneck using two M5x25 Cap Screws. Step 7 - 14 Refer to page 9 and 10 (follow step 10 - 17). View once the Metal Gate Station Rear Housing and Gooseneck Backing Plate have been fastened onto the Gooseneck page 11 FIGURE 15 Gooseneck FIGURE 16 FIGURE 17 www.centsys.com SECTION 5 COMPLETING THE INSTALLATION 5. COMPLETING THE INSTALLATION 5.1. Wiring a G-SPEAK ULTRA to the Metal Gate Station 5.1.1. DX Controller G-SPEAK ULTRA DX Control Card GND IO1 IO2 IO3 IO4 P1 P2 P3 P4 P5 P6 VIN NEG The I/Os are configured using MyCentsys Pro. · I/O1 - TRG · I/O2 - PED · I/O4 - Gate Status · I/O5 - Alarm P1 P2 P3 P4 P5 P6 page 12 Metal Gate Station FIGURE 18 www.centsys.com SECTION 5 5.1.2. D5ES Controller G-SPEAK ULTRA GND IO1 IO2 IO3 IO4 P1 P2 P3 P4 P5 P6 VIN NEG COMPLETING THE INSTALLATION D5ES Control Card The I/Os are configured using MyCentsys Pro. · I1 - TRG · I2 - PED · I/O4 - Gate Status · I/O5 - Alarm P1 P2 P3 P4 P5 P6 Metal Gate Station FIGURE 19 page 13 www.centsys.com SECTION 5 5.1.3. D-Series Controller G-SPEAK ULTRA COMPLETING THE INSTALLATION D-Series Control Card Do not mount close to the DOSS sensor or remote receiver. GND IO1 IO2 IO3 IO4 P1 P2 P3 P4 P5 P6 VIN NEG P1 P2 P3 P4 P5 P6 page 14 Metal Gate Station FIGURE 20 www.centsys.com SECTION 5 5.1.4. VX SMART Controller G-SPEAK ULTRA COMPLETING THE INSTALLATION VX SMART Control Card Do not mount close to the sensor wiring or remote receiver. GND IO1 IO2 IO3 IO4 P1 P2 P3 P4 P5 P6 VIN NEG The I/Os are configured using MyCentsys Pro. · I1 - TRG · I2 - PED · I/O4 - Gate Status · I/O5 - Alarm P1 P2 P3 P4 P5 P6 page 15 Metal Gate Station FIGURE 21 www.centsys.com SECTION 6 6. WARRANTY INFORMATION WARRANTY INFORMATION You can register your product(s) online at www.centsys.com, which will assist you in keeping a record of your date of purchase or installation, serial numbers, etc. All of our products are manufactured with extreme care, thoroughly inspected and tested. The goods supplied by us shall be subject to the provisions of sections 55 to 57 of the Consumer Protection Act (68/2008) except where the provisions of the warranty contained in our product documentation are more favourable to the purchaser. Subject to the warranty contained in our product documentation, if applicable, our products are warranted for a period of twenty-four months after delivery. However, it is expressly noted that batteries carry a six month warranty due to the nature of these products being such that they are subject to possible misuse. Please note that warranties will be honoured on a carry-in basis; in other words, the product in question must be taken in to one of our branches, or to the authorised reseller that the product was purchased from, for assessment and, if necessary, repair. For equipment not of our manufacture, the warranty as supplied by the original manufacturer will apply if such warranty is more favourable to the purchaser than the relevant provisions of the Consumer Protection Act (Act 68/2008 of South Africa), or any other applicable law as so required in different countries in which the product was sold. Such warranty is valid only once full payment has been received for such goods. Australian customers: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Any warranty may be voidable on any equipment which: 1. Has not been installed in accordance with the installation instructions provided. 2. Has been subject to misuse or which has been used for any purpose other than that designed for by the manufacturers. 3. Has damage caused as a result of handling during transit, atmospheric conditions (including lightning), corrosion of metal parts, insect infestation, power surges or other forces outside of the control of the manufacturer. 4. Has been repaired by any workshop and / or person NOT previously authorised by the manufacturer. 5. Has been repaired with components not previously tested, passed or authorised by Centurion Systems (Pty) Ltd, South Africa or one of its subsidiary companies. page 16 www.centsys.com Notes page 17 www.centsys.com Notes page 18 www.centsys.com Notes page 19 www.centsys.com Connect with us on: International Customers Australian Customers @CenturionSystemsRSA @Centurion.Systems @Centurion-Systems @CenturionSystems @Centurion.Systems @AskCenturion @Centurion.Systems Centurion-Systems @FAACAustraliaPtyLtd @faac_australia_ @FAACAustralia @faacaustralia3920 Subscribe to the newsletter: www.centsys.com/subscribe WhatsApp - Technical Support South Africa: +27 (0)83 650 4010 International: +27 (0)83 650 4244 Call: 1 300 322 228 (FAAC Australia) Email: sales@faac.com.au Technical Support Email: technical.au@faactechnologies.com Monday to Friday: from 08h00 to 16h30 (GMT+2) Saturday: from 08h00 to 14h00 (GMT+2) E&OE Centurion Systems (Pty) Ltd reserves the right to change any product without prior notice All product and brand names in this document that are accompanied by the ® symbol are registered trademarks in South Africa and/or other countries, in favour of Centurion Systems (Pty) Ltd, South Africa. The CENTURION and CENTSYS logos, all product and brand names in this document that are accompanied by the TM symbol are trademarks of Centurion Systems (Pty) Ltd, in South Africa and other territories; all rights are reserved. We invite you to contact us for further details. ISO 9001:2015 Doc number: 1411.D.01.0001_25022025 www.centsys.com www.centsys.com.au