Introduction
The PeakTech 2510 is a versatile power analyzer designed for accurate measurement of various electrical parameters. It complies with European Union directives for electromagnetic compatibility and low voltage.
Safety Precautions
Users must adhere to the safety guidelines outlined in this manual to prevent injury and equipment damage. Key safety points include:
- Never exceed the maximum input values.
- Inspect test leads for damaged insulation before use.
- Avoid touching the tips of the measurement probes.
- Pay attention to all warning labels on the device.
- Perform measurements in dry conditions, preferably with rubber-soled shoes or on an insulating mat.
- Do not connect any voltage sources to the /COM input.
- Do not perform current measurements using the VOLT/COM terminals.
- Always select the highest measurement range for unknown variables before measuring.
- Remove test leads from the measurement circuit before switching to another measurement function.
- Avoid exposing the device to extreme temperatures, direct sunlight, or excessive humidity.
- Avoid strong vibrations.
- Do not use the device near strong magnetic fields.
- Do not use the device outdoors.
- Replace fuses only with equivalent types and never short-circuit a fuse or its holder.
- Allow the device to acclimate to room temperature before use.
Features
The PeakTech 2510 offers a wide range of measurement functions, including:
- Power factor (COSθ), AC voltage, AC current, DC voltage, DC current, frequency, and resistance.
- True RMS measurement for AC voltage (ACV) and AC current (ACA).
- Simultaneous display of current and voltage.
- Automatic range selection.
- Accepts various current input signals via current transformers or clamp adapters.
- Built-in peak hold and data hold functions.
- Alarm function for exceeding Hi-Lo limit values.
- RS-232 interface for data output.
- Overvoltage indicator.
- Battery or AC/DC adapter operation.
- Battery level indicator.
- Robust plastic housing with a carrying handle.
Technical Specifications
Detailed technical specifications for the PeakTech 2510 are provided, covering display, dimensions, operating conditions, power supply, and measurement ranges for various parameters like Watt, VA, Power Factor, Voltage, Current, and Resistance.
Operation
The manual guides users through various measurement procedures, including:
- AC Watt, V/A/PF/Hz measurement.
- AC VA/V/A/PF/Hz measurement.
- Watt-hour (Whr) measurement.
- AC voltage and current measurement.
- DC voltage and current measurement.
- Resistance measurement.
- Measurements using current transformers and clamp adapters.
Instructions for using the data hold, peak hold, and alarm functions are also included.
Maintenance
Information on battery replacement and general cleaning is provided. Users are advised to replace batteries when the "BAT" signal appears on the LCD and to clean the casing with a dry cloth only.
Connectivity
The document details the RS-232 PC interface, including connection diagrams and data format specifications for transmitting measurement data to a computer.