Safety Instructions

  • Disconnect the product from the mains before connecting, maintenance, and/or repair.
  • Installation, maintenance, and/or repairs should be carried out by an authorized electrician in accordance with these instructions.
  • The product is intended for connection to 230 V, 1-phase installations that comply with local regulations.
  • The product must be connected via a permanently installed automatic fuse with a minimum contact gap of 3 mm on all terminals.
  • Check before installation that the impeller and casing are undamaged.
  • Ensure there are no foreign objects in the casing that could damage the fan blades.
  • Use the product only for its intended purpose and in accordance with these instructions. Do not make any modifications.
  • The product is not intended for use by persons (children or adults) with functional disorders or lack of experience/knowledge, unless supervised by a responsible person.
  • Keep children supervised to ensure they do not play with the product.
  • Take precautions to prevent smoke, carbon monoxide, and other combustion products from entering the room through flues or fire safety devices.
  • Ensure sufficient air supply for correct combustion and adequate chimney draught to prevent backward flow.
  • The transported medium must not contain dust, solid particles, sticky substances, or fibres.
  • Do not use the product in explosive environments (near flammable liquids, gas, dust) or in environments with toxic or harmful substances.
  • Do not block the product's openings to direct or adjust airflow.
  • The product is intended for permanent connection to the mains.

Symbols

  • [Read instructions]
  • [Safety Class II]
  • [CE Approved]
  • [Recycle Symbol]

Electrical Safety

New installations and extensions to existing systems should always be carried out by an authorized electrician. If you have the necessary experience and knowledge (otherwise contact an electrician), you can replace power switches and wall sockets, fit plugs, extension cords, and light sockets. Incorrect installation can result in fatal injury and the risk of fire.

Description

This is an axial fan made of plastic, designed for supply and exhaust air ventilation in small and medium-sized homes heated during winter. The product is intended for connection to a Ø100 mm air duct. It is designed for continuous operation and permanent connection to the mains. The airflow direction in the system must correspond to the arrow on the fan casing.

Technical Data

SpecificationValue
Model012894
Voltage230 V ~ 50 Hz
Output14 W
DuctØ100 mm
Air Flow107 m³/hour
Safety ClassII
Protection RatingIPX4
Operating Temperature1 to 45 °C
Air Temperature in Ventilation System< 40 °C
Noise Level56 dB(A)
Size115 x Ø98 mm
Specific Energy Consumption (Cold/Medium/Hot)-31 kWh/m² / -15 kWh/m² / -5 kWh/m²
Type of Ventilation UnitUnidirectional
Type of Drive UnitVariable Speed
Annual Power Consumption (Cold/Medium/Hot)1 kWh / 1 kWh / 1 kWh
Annual Savings of Primary Energy (Cold/Medium/Hot)34 kWh / 17 kWh / 8 kWh

Installation

Follow these steps for installation:

  1. Switch off the power supply.
    [Diagram 1: Shows a wiring diagram with Live (L) and Neutral (N) wires connecting to a switch labeled 'OFF' and 'ON', with an arrow pointing to 'OFF'.]
  2. Remove the junction box cover and the retaining clip.
    [Diagram 2: Illustrates removing the junction box cover and the retaining clip.]
  3. Connect the fan to the mains power, reattach the retaining clip, and set a delay if necessary.
    [Diagram 3: Depicts connecting the fan to the mains power, reattaching the retaining clip, and setting a delay function if applicable.]
  4. Replace the junction box cover.
    [Diagram 4: Shows replacing the junction box cover.]
  5. Connect the air ducts to both sides of the fan.
    [Diagram 5: Illustrates connecting the air ducts to both sides of the fan.]
  6. Connect the power supply.

Maintenance

Regular maintenance ensures optimal performance:

  1. Switch off the power supply.
    [Diagram 6: Shows switching off the power supply.]
  2. Release the air ducts.
    [Diagram 7: Depicts disconnecting the air ducts from the fan.]
  3. Clean the product with a cloth moistened with water and a mild detergent. Wipe the surfaces dry.
    [Diagram 8: Illustrates cleaning the fan's exterior with a cloth moistened with water and mild detergent, followed by drying.]
  4. Clean the fan vanes and the inside of the fan using a small brush or paintbrush.
    [Diagram 9: Illustrates cleaning the fan vanes and interior using a small brush or paintbrush.]
  5. Connect the air ducts to the fan.
  6. Connect the power supply.

Note:

  • Ensure no water enters the electrical components.
  • Maintenance should be carried out at least once every 6 months.

Wiring Diagram Designations

  • L: Live wire
  • N: Neutral wire
  • QF: Automatic fuse
  • S: External power switch

Contact: www.jula.com

Models: 012894, Pipe Fan 100 mm

PDF preview unavailable. Download the PDF instead.

012894 220127 se-no-pl-en-de-fi Adobe InDesign 17.0 (Windows) Adobe PDF Library 16.0.3

Related Documents

Preview Jula Metal Fan (020619) - Operating Instructions and Specifications
Comprehensive operating instructions, safety warnings, technical specifications, and maintenance guide for the Jula Metal Fan (Item No. 020619). Learn how to safely operate, maintain, and troubleshoot your fan.
Preview Jula Wall Charger 4x USB A - Operating Instructions and Technical Data
This document provides operating instructions, safety information, and technical specifications for the Jula Wall Charger 4x USB A, model 024611. It is available in multiple languages including Swedish, Norwegian, Danish, Polish, English, German, Finnish, French, and Dutch.
Preview LED Floodlight Operating Instructions and Technical Data
Comprehensive guide for the Jula LED Floodlight, including operating instructions, safety precautions, technical specifications, and mounting/disassembly procedures in multiple languages.
Preview Jula Luftdriven Spikpistol 20-50 mm Installations- och Säkerhetsinstruktioner
Denna manual ger omfattande information för säker och effektiv användning av Jula Air Nailer (Modell 071031) från MEEC TOOLS. Manualen täcker installation, drift, säkerhetsföreskrifter, underhåll och felsökning, med tekniska specifikationer och instruktioner på flera språk.
Preview Jula Convector Heater Operating Instructions
This document provides operating instructions and safety information for the Jula Convector Heater, model 417-013. It includes details on installation, usage, maintenance, and storage in multiple languages.
Preview Jula 2.5 Ton Garage Jack Operating Instructions and Safety Guide
Detailed operating instructions and safety guidelines for the Jula 2.5 Ton Garage Jack (Item No. 012148), covering lifting, lowering, maintenance, and storage.
Preview Jula Universal Dimmer - Operating Instructions
Comprehensive operating instructions for the Jula Universal Dimmer, covering safety warnings, technical data, installation steps, and usage guidance. Includes information on environmental care and product updates from Jula.
Preview JULA PIR Detector 422080, 422081: Operating Instructions and Installation Guide
Comprehensive operating instructions and installation guide for the JULA PIR Detector (models 422080, 422081). Learn about technical specifications, optimal placement, mounting procedures, and functional settings for motion detection.