Jula Pipe Fan - Model 012894
Safety Instructions
- Disconnect the product from the mains before connecting, maintenance, and/or repair.
- Installation, maintenance, and/or repairs should be carried out by an authorized electrician in accordance with these instructions.
- The product is intended for connection to 230 V, 1-phase installations that comply with local regulations.
- The product must be connected via a permanently installed automatic fuse with a minimum contact gap of 3 mm on all terminals.
- Check before installation that the impeller and casing are undamaged.
- Ensure there are no foreign objects in the casing that could damage the fan blades.
- Use the product only for its intended purpose and in accordance with these instructions. Do not make any modifications.
- The product is not intended for use by persons (children or adults) with functional disorders or lack of experience/knowledge, unless supervised by a responsible person.
- Keep children supervised to ensure they do not play with the product.
- Take precautions to prevent smoke, carbon monoxide, and other combustion products from entering the room through flues or fire safety devices.
- Ensure sufficient air supply for correct combustion and adequate chimney draught to prevent backward flow.
- The transported medium must not contain dust, solid particles, sticky substances, or fibres.
- Do not use the product in explosive environments (near flammable liquids, gas, dust) or in environments with toxic or harmful substances.
- Do not block the product's openings to direct or adjust airflow.
- The product is intended for permanent connection to the mains.
Symbols
- [Read instructions]
- [Safety Class II]
- [CE Approved]
- [Recycle Symbol]
Electrical Safety
New installations and extensions to existing systems should always be carried out by an authorized electrician. If you have the necessary experience and knowledge (otherwise contact an electrician), you can replace power switches and wall sockets, fit plugs, extension cords, and light sockets. Incorrect installation can result in fatal injury and the risk of fire.
Description
This is an axial fan made of plastic, designed for supply and exhaust air ventilation in small and medium-sized homes heated during winter. The product is intended for connection to a Ø100 mm air duct. It is designed for continuous operation and permanent connection to the mains. The airflow direction in the system must correspond to the arrow on the fan casing.
Technical Data
Specification | Value |
---|---|
Model | 012894 |
Voltage | 230 V ~ 50 Hz |
Output | 14 W |
Duct | Ø100 mm |
Air Flow | 107 m³/hour |
Safety Class | II |
Protection Rating | IPX4 |
Operating Temperature | 1 to 45 °C |
Air Temperature in Ventilation System | < 40 °C |
Noise Level | 56 dB(A) |
Size | 115 x Ø98 mm |
Specific Energy Consumption (Cold/Medium/Hot) | -31 kWh/m² / -15 kWh/m² / -5 kWh/m² |
Type of Ventilation Unit | Unidirectional |
Type of Drive Unit | Variable Speed |
Annual Power Consumption (Cold/Medium/Hot) | 1 kWh / 1 kWh / 1 kWh |
Annual Savings of Primary Energy (Cold/Medium/Hot) | 34 kWh / 17 kWh / 8 kWh |
Installation
Follow these steps for installation:
- Switch off the power supply. [Diagram 1: Shows a wiring diagram with Live (L) and Neutral (N) wires connecting to a switch labeled 'OFF' and 'ON', with an arrow pointing to 'OFF'.]
- Remove the junction box cover and the retaining clip. [Diagram 2: Illustrates removing the junction box cover and the retaining clip.]
- Connect the fan to the mains power, reattach the retaining clip, and set a delay if necessary. [Diagram 3: Depicts connecting the fan to the mains power, reattaching the retaining clip, and setting a delay function if applicable.]
- Replace the junction box cover. [Diagram 4: Shows replacing the junction box cover.]
- Connect the air ducts to both sides of the fan. [Diagram 5: Illustrates connecting the air ducts to both sides of the fan.]
- Connect the power supply.
Maintenance
Regular maintenance ensures optimal performance:
- Switch off the power supply. [Diagram 6: Shows switching off the power supply.]
- Release the air ducts. [Diagram 7: Depicts disconnecting the air ducts from the fan.]
- Clean the product with a cloth moistened with water and a mild detergent. Wipe the surfaces dry. [Diagram 8: Illustrates cleaning the fan's exterior with a cloth moistened with water and mild detergent, followed by drying.]
- Clean the fan vanes and the inside of the fan using a small brush or paintbrush. [Diagram 9: Illustrates cleaning the fan vanes and interior using a small brush or paintbrush.]
- Connect the air ducts to the fan.
- Connect the power supply.
Note:
- Ensure no water enters the electrical components.
- Maintenance should be carried out at least once every 6 months.
Wiring Diagram Designations
- L: Live wire
- N: Neutral wire
- QF: Automatic fuse
- S: External power switch
Contact: www.jula.com