ELATEC TWN4 Secustos Family

TWN4 Secustos MU20, TWN4 Secustos SG30, TWN4 Secustos SQ80

USER MANUAL - ONLINE USER GUIDE

1 INTRODUCTION

1.1 ABOUT THIS MANUAL

This manual is intended for users and installers. It enables the safe and appropriate handling with, and installation of TWN4 Secustos readers and provides a general overview, as well as important technical data and safety information about the product. Users and installers should read and understand the content of this manual before installing the product.

For better understanding and readability, this manual may contain exemplary pictures, drawings, and other illustrations. Depending on your product configuration, these pictures might differ from the actual design of your product.

The original version of this manual has been written in English. Wherever the manual is available in another language, it is considered a translation of the original document for information purposes only. In case of discrepancy, the original English version will prevail.

1.2 ELATEC SUPPORT

For any technical questions or product malfunction, refer to the ELATEC website (www.elatec.com) or contact ELATEC technical support at support-rfid@elatec.com.

For questions regarding your product order, contact your Sales representative or ELATEC customer service at info-rfid@elatec.com.

2 SAFETY INFORMATION

Transport and storage

  • Carefully observe the transport and storage conditions described on the product packaging or other relevant product documents (e.g., data sheet).

Unpacking and installation

  • Before unpacking and installing the product, this manual and all relevant installation instructions must be read carefully and understood.
  • The product may have sharp edges or corners and requires particular attention during unpacking and installation. Unpack the product carefully and do not touch any sharp edges or corners, or any sensitive components. Wear safety gloves if necessary.
  • After unpacking, check that all components have been delivered according to your order and delivery note. Contact ELATEC if your order is not complete.
  • The following measures must be checked prior to any product installation:
    • Ensure the mounting location and tools used for installation are appropriate and safe. Ensure the cables intended for installation are appropriate. Refer to the "Installation" chapter for more information.
    • If the product is installed outdoors, check if any further installation steps are required (e.g., sealing of cables or housing). Refer to the "Installation" chapter for more information.
    • The product is an electrical device made of sensitive materials (e.g., glass housing). Check all product components and accessories for any damage. A damaged product or component may not be used for installation.
    • Life-threatening hazard in the event of fire: A faulty or improper installation may cause a fire, leading to death or severe injuries. Check that the mounting location is equipped with appropriate safety installations and devices, such as a smoke alarm or fire extinguisher.
    • Life-threatening hazard due to electrical shock: Ensure there is no voltage on the wires before starting electrical wiring and check that power is turned off by testing the power supply of each wire. The product may be supplied with power only after installation is completed. Ensure the product is installed in accordance with local electrical standards and regulations and observe general safety measures.
    • Risk of property damage due to transient overvoltage (surges): Transient overvoltage implies short-duration voltage peaks that might result in system breakdown or significant damage to electrical installations and devices. ELATEC recommends the installation of appropriate Surge Protection Devices (SPD) by qualified and authorized personnel.
    • ELATEC also recommends installers follow general ESD protective measures during installation.
    • Please refer to the safety information in the "Installation" chapter.

Installation Requirements

  • The product must be installed in conformity with applicable local regulations. Check if a minimum installation height is mandatory and observe all regulations applicable in the region of installation.
  • The product features an IP65-protected housing suitable for both indoor and outdoor installation. When installing outdoors, the mounting frame must always be used to comply with the IP65 protection class.
  • To comply with applicable RF exposure requirements, the product should be installed and operated with a minimum distance of 20 cm to any user's/nearby person's body at all times. The product is exempt from SAR at touch position. Refer to the "Compliance statements" chapter for further information about RF exposure compliance.
  • If the product is equipped with a cable, do not twist or pull the cable excessively.
  • The product is an electronic device requiring specific skills and expertise for installation. Installation should be performed by trained and qualified personnel only.

Handling

Warning: Powering the product with more than one power source simultaneously or using it as a power supply for other devices may lead to injuries or property damage.

  • Do not power the product via more than one power source at the same time.
  • Do not use the product as a power supply for other devices.
  • Depending on your product configuration, the product may be equipped with one or more light-emitting diodes (LED). Avoid direct eye contact with the blinking or steady light of the LEDs.
  • The product has been designed for use under specific conditions, e.g., within a specific temperature range (refer to the product data sheet). Use under different conditions might damage the product or alter its reading performance.
  • The use of other RFID devices in direct vicinity or in combination with the product might damage the product or alter its reading performance. In case of doubts, contact ELATEC for more information.
  • The user is liable for the use of spare parts or accessories other than those sold or recommended by ELATEC. ELATEC excludes any liability for damages or injuries resulting from the use of non-approved spare parts or accessories.
  • If the product is equipped with a cable, the cable may not be replaced or extended. ELATEC excludes any liability for damages or injuries resulting from the use of the product with a cable extension or a replaced cable.
  • Like most electronic devices, RFID systems generate electromagnetic waves that can vary in amplitude and frequency. It is generally known and accepted that some RFID devices might potentially interfere with personal medical devices, like pacemakers or hearing aids.

Maintenance and cleaning

  • Any repair or maintenance work should be done by trained and qualified personnel only. Do not allow repair or maintenance work by unqualified or unauthorized third parties.
  • Life-threatening hazard due to electrical shock: Before any repair or maintenance work, the power must be turned off.
  • Check the installation and electrical connection of the product at regular intervals for any signs of damage or wear. Should any damage or wear be noticed, contact ELATEC or a trained and qualified personnel for repair or maintenance work.
  • The product does not require special cleaning. However, the housing may be carefully cleaned with a soft, dry cloth and a non-aggressive or non-halogenated cleaning agent on the outer surface only. Ensure the cloth and cleaning agent do not damage the product or its components (e.g., label(s)).

Disposal

  • The product must be disposed of in accordance with applicable local regulations.

Product modifications

  • The product has been designed, manufactured, and certified by ELATEC. Any product modification without prior written approval from ELATEC is prohibited and considered improper use. Unauthorized product modifications may also result in the loss of product certifications.

If you are unsure about any part of the safety information above, contact ELATEC support. Any failure to comply with the safety information given in this document is considered improper use. ELATEC excludes any liability in case of improper use or faulty product installation.

3 PRODUCT DESCRIPTION

3.1 INTENDED USE

TWN4 Secustos is a product family of access control readers based on RFID technology. It allows users to read RFID media in the 125 kHz (LF) and 13.56 MHz (HF) frequency bands. The readers also support BLE (2.4 GHz) technology and are designed for physical access control applications. They are suitable for both indoor and outdoor use in environmental conditions according to the respective product data sheets and installation instructions. The readers are for professional use only.

Any use other than the intended use described in this section, as well as any failure to comply with the safety information given in this document, is considered improper use. ELATEC excludes any liability in case of improper use or faulty product installation.

3.2 PRODUCT FAMILY

The TWN4 Secustos family contains the following reader models:

Figure 1: TWN4 Secustos MU20 readers.

Figure 2: TWN4 Secustos SG30 readers.

Figure 3: TWN4 Secustos SQ80 readers.

Frequencies125 kHz (LF) / 13.56 MHz (HF) / 2.4 GHz (BLE)
AntennasIntegrated RFID LF antenna: Outer diameter: max. 17.00 mm / 0.67 inch, Number of turns: typ. 135, max. 140
Integrated RFID HF antenna: Outer dimensions: 66.00 x 26.00 mm / 2.60 x 1.02 inch, Number of turns: 3
Bluetooth Low Energy: Integrated BLE module
HousingMetal frame and glass front, potted housing. Available in 2 colors (silver or gray).
Dimensions (L x W x H)Reader frame only (mounted): approx. 123.00 x 42.00 x 8.25 mm / 4.84 x 1.65 x 0.32 inch
Rear connector height: approx. 8.00 mm / 0.31 inch
Reader with rear connector: approx. 123.00 x 42.00 x 15.90 mm / 4.84 x 1.65 x 0.62 inch
Optional mounting frame: approx. 123.00 x 42.00 x 9.75 mm / 4.84 x 1.65 x 0.38 inch
PowerConnector X1: 6.0 V – 28 V¹. ES1/PS2 classified power source according to IEC 62368-1, short-circuit current < 3.5 A
Current consumptionMax. 300 mA @ 6.0 V
Temperature rangeOperating: -20 °C up to +60 °C / -4 °F up to +140 °F
Storage: -20 °C up to +70 °C / -4 °F up to +158 °F
WeightReader, potted, with connectors and mounting plate: approx. 87.50 g / 3.09 oz
Relative HumidityMounted front: IP65 protected housing
Transport/Storage: 5% to 95% non-condensing
Reader performance levels²Destructive attack: Level I
Line security: Level I
Endurance: Level IV
Standby power: Level I

Refer to the data sheet of your product for additional technical specifications.

¹ For installation in a UL-certified environment, please observe the input voltage of 10 V – 28 V.

² As per UL 294 8th Ed.

Frequencies125 kHz (LF) / 13.56 MHz (HF) / 2.4 GHz (BLE)
AntennasIntegrated RFID LF antenna: Outer diameter: max. 17 mm / 0.67 inch, Number of turns: typ. 135, max. 140
Integrated RFID HF antenna: Outer dimensions: 65 x 41 mm / 2.56 x 1.61 inch, Number of turns: 3
Bluetooth Low Energy: Integrated BLE module
HousingMetal frame and glass front, potted housing. Available in 2 colors (silver or gray).
Dimensions (L x W x H)Reader frame only (mounted): approx. 123.00 x 86.00 x 8.25 mm / 4.84 x 3.38 x 0.32 inch
Rear connector height: approx. 8.00 mm / 0.31 inch
Reader with rear connector: approx. 123.00 x 86.00 x 15.90 mm / 4.84 x 3.38 x 0.62 inch
Optional mounting frame: approx. 123.00 x 86.00 x 9.75 mm / 4.84 x 3.38 x 0.38 inch
PowerConnector X1: 6.0 V – 28 V³. ES1/PS2 classified power source according to IEC 62368-1, short-circuit current < 3.5 A
Current consumptionMax. 300 mA @ 6.0 V
Temperature rangeOperating: -20 °C up to +60 °C / -4 °F up to +140 °F
Storage: -20 °C up to +70 °C / -4 °F up to +158 °F
WeightReader, potted, with connectors and mounting plate: approx. 150 g / 5.29 oz
Relative HumidityMounted front: IP65 protected housing
Transport/Storage: 5% to 95% non-condensing
Reader performance levels⁴Destructive attack: Level I
Line security: Level I
Endurance: Level IV
Standby power: Level I

³ For installation in a UL-certified environment, please observe the input voltage of 10 V – 28 V.

⁴ As per UL 294 8th Ed.

Frequencies125 kHz (LF) / 13.56 MHz (HF) / 2.4 GHz (BLE)
AntennasIntegrated RFID LF antenna: Outer diameter: max. 17.00 mm / 0.67 inch, Number of turns: typ. 135, max. 140
Integrated RFID HF antenna: Outer dimensions: 64.00 x 32.00 mm / 2.52 x 1.26 inch, Number of turns: 3
Bluetooth Low Energy: Integrated BLE module
HousingMetal frame and glass front, potted housing. Available in 2 colors (silver or gray).
Dimensions (L x W x H)Reader frame only (mounted): approx. 86.00 x 86.00 x 8.25 mm / 3.38 x 3.38 x 0.32 inch
Rear connector height: approx. 8.00 mm / 0.31 inch
Reader with rear connector: approx. 86.00 x 86.00 x 15.90 mm / 3.38 x 3.38 x 0.62 inch
Optional mounting frame: approx. 86.00 x 86.00 x 9.75 mm / 3.38 x 3.38 x 0.38 inch
PowerConnector X1: 6.0 V – 28 V⁵. ES1/PS2 classified power source according to IEC 62368-1, short-circuit current < 3.5 A
Current consumptionMax. 300 mA @ 6.0 V
Temperature rangeOperating: -20 °C up to +60 °C / -4 °F up to +140 °F
Storage: -20 °C up to +70 °C / -4 °F up to +158 °F
WeightReader, potted, with connectors and mounting plate: approx. 113 g / 3.99 oz
Relative HumidityMounted front: IP65 protected housing
Transport/Storage: 5% to 95% non-condensing
Reader performance levels⁶Destructive attack: Level I
Line security: Level I
Endurance: Level IV
Standby power: Level I

Refer to the data sheet of your product for additional technical specifications.

⁵ For installation in a UL-certified environment, please observe the input voltage of 10 V – 28 V.

⁶ As per UL 294 8th Ed.

3.3 CREDENTIAL-RELEVANT SPECIFICATIONS

Electronic credential transmission technologyRFID / BLE
125 kHz: TWN4 LF module UL V1.0.0.0, (ASK, PSK, FSK)
13.56 MHz and BLE (common chip): HF frontend UL V1.0.0.0, ISO 14443A, ISO 14443B, BLE 4.2
Wireless electronic device OS revisionTWN4 Firmware UL V1.0.0.2
Wireless electronic credential device application softwareTWN4 OSDP App UL V1.0.0.0
User verificationAccess for administration and maintenance is only possible directly via the host software.
Credential identificationInformation from cards is sent to the access control system according to end user need. The reader identifies credentials and passes the information to the access control system if required.

3.4 FIRMWARE

Your product is delivered ex-works with a specific firmware version. Refer to the label attached to the product to find the firmware version installed ex-works.

3.5 LABELING

Your product is delivered ex-works with a label containing important product information (e.g., firmware, serial no.). This label may not be removed or damaged. In case of label wear-out, contact ELATEC.

3.6 SCOPE OF DELIVERY

3.6.1 COMPONENTS

The TWN4 Secustos readers are delivered as a kit with the following components:

  • Reader: All TWN4 Secustos readers are equipped ex-works with one 4-pin (X1) and one 6-pin (X2) connector. Depending on the product configuration, the readers are available with or without keypad, in a silver or gray housing.
  • Mounting plate: The mounting plate delivered with the kit enables fixing the TWN4 Secustos reader on a wall. It must be fixed directly to the wall or on a flush-mounted box with 2 to 4 screws⁷.

⁷ Not part of the delivery (screws are generally available on site)

Fixing screw

Countersunk screw with cross recess, M3x6. M2x5 (for TWN4 Secustos MU20 and TWN4 Secustos SQ80 models). M3x6 (for TWN4 Secustos SG30 model).

The fixing screw is intended to fix the TWN4 Secustos reader on the mounting plate. Due to its small size and inconspicuousness, particular attention should be given to the screw when unpacking the kit, as it might easily fall down and get lost.

Instructions for use

The instructions for use delivered with the product contain important instructions and safety information and must be read carefully before installing and using the product.

3.6.2 ACCESSORIES

Depending on your product configuration, the product can be delivered with the following accessories:

  • Mounting frame⁸: Additional frame required for on-wall installation. The mounting frame is delivered with 4 fixing screws (ISO 7046-1 stainless steel A2 M3x6) and 2 rubber seals on each side of the frame. When installing the reader outdoors, the mounting frame must always be used to comply with the IP65 protection class.
  • USB cable: Product-specific USB cable intended for maintenance and configuration purposes only. Particular attention should be given when plugging the USB cable in and out of a TWN4 Secustos reader.

⁸ To comply with UL certification requirements, the mounting frame must always be used when installing the reader outdoors. Any failure to meet this requirement will void the UL certification of the product.

4 INSTALLATION

4.1 GETTING STARTED

Before starting the installation of a TWN4 Secustos reader, the following measures must be checked:

  • Ensure you have read and understood all safety information given in the "Safety information" chapter.
  • Ensure there is no voltage on the wires and that power is turned off by testing the power supply of each wire.
  • Ensure all tools and components required for installation are available and appropriate.
  • Ensure the installation site is appropriate for the reader. Check that the installation site temperature is within the operating temperature range given in the TWN4 Secustos technical documentation and that the wall used for installation is appropriate. In some cases, the wall material might not be suitable for a safe and durable installation, or it might require specific mounting screws (e.g., drywall). Furthermore, some materials might interfere with the RFID antennas and reduce reading performance (e.g., metallic surfaces). Contact ELATEC for more information.
  • The reader should be installed at an appropriate and service-friendly height. ELATEC recommends an installation height of 110 cm from the ground for standard installation. However, in some cases (e.g., wheelchair access, local regulations), the actual installation height may differ. Note the maximum wall mounting height of 200 cm from the ground.
  • If other RFID devices are already installed on site, or if several TWN4 Secustos readers must be installed, observe a minimum distance of 30 cm between all readers and devices for optimal reading performance. If two readers are installed in the same location (e.g., on each side of a wall, next to a door), the wall thickness should also be at least 30 cm to prevent performance loss for both readers.

Figure 4: Example 1: Installation of 2 readers next to each other, showing a 300mm (11.81 inch) separation.

Figure 5: Example 2: Installation of 2 readers on each side of a wall, indicating a minimum 300mm (11.81 inch) wall thickness.

  • The protective film on the housing front should only be removed after complete installation of the reader.
  • When installing the reader, do not cover the upper part (between the LEDs), as this would disable both proximity and ambient light sensors.

Figure 6: TWN4 Secustos SG30 reader, highlighting proximity and ambient light sensors.

4.2 INSTALLATION SITE REQUIREMENTS

TWN4 Secustos readers can be installed in any locations that meet the requirements listed in this manual and in the respective data sheets. The installation site must comply with the following requirements:

  • Relative humidity: 5% to 95%, non-condensing.
  • Ambient temperature within the operating temperature range of the reader: -20 °C up to +60 °C / -4 °F up to +140 °F.
  • Installation height (from the ground) < 200 cm (110 cm recommended).

Any location not meeting these requirements is not appropriate for the installation of a TWN4 Secustos reader.

4.3 INSTALLATION OVERVIEW

The illustration below gives an overview of an exemplary installation of a TWN4 Secustos reader:

Figure 7: Exemplary installation overview showing a reader installed on a door, with internal and external views, wall opening, flush-mounted box, and standard height measurement (110 cm/43 inch from ground to box center).

4.4 ELECTRICAL CONNECTION

4.4.1 CONNECTOR ASSIGNMENT

Figure 8: 4-pin connector (X1) with pin assignments for Power Supply (V+, V-) and Data Transfer (A+, B-, D0, D1, IN1, IN2, IN3, INS).

Figure 9: 6-pin connector (X2) with pin assignments for Data Transfer and Maintenance/Configuration (USB).

Power supply
V+Input voltage 6 – 28 V⁹
V-Ground
Data transfer¹⁰
A+RS-485, cable length: max. 1000 m
B-RS-485, cable length: max. 1000 m
D0Wiegand D0, cable length: max 200 m
D1Wiegand D1, cable length: max 200 m
IN1Digital input 1, cable length: max 200 m
IN2Digital input 2, cable length: max 200 m
IN3Digital input 3, cable length: max 200 m
INSDigital input S (for external Sabotage switch), optional if sabotage button is not available on the reader, cable length: max 200 m

Cable routing requirements: twisted pair cabling (D0/GND, D1/GND).

Maintenance / Configuration
USB4-pin USB connector, 1.25 mm pitch (for maintenance and configuration purposes only)

⁹ For installation in a UL-certified environment, please observe the input voltage of 10 – 28 V.

¹⁰ For installation in a UL-certified environment, please observe the max. cable length of 30 m. In addition, the minimum permissible wire size to be used shall not be less than 23 AWG (0.28 mm²).

4.4.2 CABLE INFORMATION

Typical installation cables are JY(ST)Y 4x2x0.6 or JY(ST)Y 4x2x0.8.

Alternatively, any other appropriate cables that meet the prerequisites of RS-485 installations and wirings can be used. The installation cable used to connect the controller must contain a cable shield and/or a drain wire with PE connection.

4.4.3 WIRING DIAGRAM

The diagrams below illustrate a typical wiring installation of the reader(s) in different configurations:

Figure 10: Wiring diagram for a single reader connected to an Access Controller via RS485.

Figure 11: Wiring diagram for two readers connected to an Access Controller via RS485 in a daisy-chain configuration.

Figure 12: Wiring diagram for two readers connected to an Access Controller via RS485 in a daisy-chain configuration. This configuration is technically feasible but not tested under UL 294 certification.

4.5 MOUNTING OPTIONS

For installation in a UL-certified environment: To comply with UL certification requirements, the mounting frame must always be used when installing the reader outdoors. Failure to meet this requirement will void the UL certification of the product.

4.5.1 TWN4 SECUSTOS MU20

  1. Fix the mounting frame to the wall as described below.

Diagram showing the mounting frame being fixed to the wall with mounting screws and rubber seals.

  1. The mounting frame is equipped with a cable inlet on its bottom side, which also serves as a cable strain relief. The cable inlet can optionally be sealed with silicone.

Diagram showing the mounting frame with a cable inlet and silicone sealing for strain relief.

  1. Finally, attach the mounting plate to the mounting frame, and the reader to the mounting plate as described below.

Diagram illustrating the assembly: mounting plate attached to mounting frame with fixing screws, and reader attached to mounting plate with a fixing screw.

4.5.2 TWN4 SECUSTOS SG30

4.5.2.1 INSTALLATION DIRECTLY ON THE WALL

  1. Fix the mounting frame to the wall as described below.

Diagram showing the mounting frame being fixed to the wall with mounting screws and rubber seals.

  1. The mounting frame is equipped with a cable inlet on its bottom side, which also serves as a cable strain relief. The cable inlet can optionally be sealed with silicone.

Diagram showing the mounting frame with a cable inlet and sealant/silicone for strain relief.

  1. Finally, attach the mounting plate to the mounting frame, and the reader to the mounting plate as described below.

Diagram illustrating the assembly: mounting plate attached to mounting frame with fixing screws, and reader attached to mounting plate with a fixing screw.

4.5.2.2 INSTALLATION WITH FLUSH-MOUNTED BOX

  1. Attach the mounting plate to the flush-mounted box, and the reader to the mounting plate as described below.

Diagram showing the assembly: mounting plate attached to a flush-mounted box, and reader attached to the mounting plate with a fixing screw.

4.5.3 TWN4 SECUSTOS SQ80

4.5.3.1 INSTALLATION DIRECTLY ON THE WALL

  1. Fix the mounting frame to the wall as described below.

Diagram showing the mounting frame being fixed to the wall with mounting screws and rubber seals.

  1. The mounting frame is equipped with a cable inlet on its bottom side, which also serves as a cable strain relief. The cable inlet can optionally be sealed with silicone.

Diagram showing the mounting frame with a cable inlet and sealant/silicone for strain relief.

  1. Finally, attach the mounting plate to the mounting frame, and the reader to the mounting plate as described below.

Diagram illustrating the assembly: mounting plate attached to mounting frame with fixing screws, and reader attached to mounting plate with a fixing screw.

4.5.3.2 INSTALLATION WITH FLUSH-MOUNTED BOX

  1. Attach the mounting plate to the flush-mounted box, and the reader to the mounting plate as described below.

Diagram showing the assembly: mounting plate attached to a flush-mounted box, and reader attached to the mounting plate with a fixing screw.

5 SETTINGS

5.1 GENERAL SETTINGS

TWN4 Secustos readers are highly flexible and versatile products supporting many types of transponder technologies¹¹. This includes operating frequency, various chip technologies, data access, and output formatting. Depending on the project and used transponders, the reader must be configured accordingly. This can be done using the AppBlaster tool. Refer to the TWN4 AppBlaster User Guide for a detailed description of the transponder configuration process.

By default, the reader is delivered ex-works with the following settings:

  • OSDP: 9600 baud
  • Address: 0
  • Terminating resistors: off
  • LED settings: The top left LED signals the device state as described below:
LED behaviorStatusExplanation
Blinking light, amberPower upAccording to the OSDP standard, no connection can be established to the reader in this first phase after powering up.
Blinking light, blueReady to Connect10 seconds after powering up, the LED starts blinking blue. It is now possible to establish an OSDP connection to the reader.
Steady light, blueIdleOnce the device is connected to the controller, the LED lights up with a steady blue light. This is the normal operating condition.
Steady light, greenCredential readAs soon as a credential has been read, the LED lights up green for two seconds, before turning back to blue again.
Blinking light, magentaSmart ConfigDuring the configuration of the device with a smartphone, the LED starts blinking magenta. This functionality can be activated as an option.

Further settings, like the optional keypad function or customer-specific configurations, are also possible and can be defined with the AppBlaster tool. Refer to the TWN4 AppBlaster User Guide for a detailed description of the configuration options.

¹¹ Only MIFARE Classic 1k and EM4102 have been tested as part of the UL 294 certification.

5.2 CONFIGURATION WITH SECUSTOS SECO APP

The reader configuration with the Secustos Seco app¹² requires an NFC-enabled mobile device (e.g., smartphone or tablet) with Android operating system (from Android 4.0). The Seco app must be downloaded from the Google Play Store and installed on the mobile device.

Seco App icon and QR code linking to the Google Play Store page for the Seco App.

Once the app is installed, parameters can be set on the mobile device and transmitted subsequently to the reader via NFC.

5.3 CONFIGURATION WITH USB CABLE

The reader can also be configured using the specific USB cable (refer to Chapter "Accessories") and the AppBlaster tool.

To do so, proceed as follows:

  1. Connect the reader to a PC with the USB cable. Particular attention should be given when plugging the USB cable in and out of the reader, as the 4-pin USB connector is a very sensitive component. Do not twist or pull excessively on the reader and press the connector lock when plugging the cable out.
  2. Open the AppBlaster tool on the PC and set the reader as requested. Refer to the TWN4 AppBlaster User Guide for more information about the reader settings.
  3. Save your settings before closing the AppBlaster tool and disconnect the reader from the PC by plugging out the USB cable carefully.

5.4 CONNECTION TO AN ACCESS CONTROLLER

A typical installation contains one or more TWN4 Secustos readers connected to a controller via RS-485. Each device operates as follows:

  • Reader: 1. Reads data from a credential¹³; 2. Formats the data; and 3. Sends it to the controller via RS-485.
  • Controller: 1. Receives data from the reader; 2. Matches the data against an access list; and 3. Grants or denies access.

The chapters below describe an exemplary installation of TWN4 Secustos SG30 with the sesamsec Secpass controller¹⁴ in two different configurations.

5.4.1 LINE TOPOLOGY

In this configuration, the reader bus consists of one reader connected to an RS-485 controller bus. An address must be assigned to the reader, and the terminating resistors of the RS-485 bus on the reader and on the controller must also be set.

Diagram showing a reader (Address: 0, Terminating resistor: on) connected to a controller (Terminating resistor: on) via RS485.

5.4.2 STAR TOPOLOGY

The following configuration is technically feasible. However, it has not been tested in accordance with UL 294. Thus, it is not part of the UL certification granted to the readers.

In this configuration, the reader bus consists of a maximum of two readers, both connected to the same RS-485 controller bus. An address must be assigned to each reader before initial operation (e.g., Reader 1 = Address 0, Reader 2 = Address 1), as two readers with the same address would cause a conflict.

The terminating resistors of the RS-485 bus on both readers must be on, whereas the terminating resistor of the RS-485 bus on the controller must be off. The terminating resistors of the RS-485 bus on the readers and on the controller must also be set.

¹⁴ The UL 294 certification granted to the TWN4 Secustos readers is not conditioned by the exclusive use of the readers with the Secpass controller described above, as the TWN4 Secustos readers have been evaluated using other controllers as part of the UL 294 certification.

Diagram showing Reader 1 (Address: 0, Terminating resistor: on) and Reader 2 (Address: 1, Terminating resistor: on) connected to a controller (Terminating resistor: off) via RS485 in a star topology.

Please note:

  • A star topology is only possible with a maximum of two readers.
  • In general, the terminating resistors of the devices opening and closing the RS-485 bus must be on. The terminating resistors of all other devices within the RS-485 bus are off.
  • An RS-485 bus should contain a maximum of two readers. Operating more than two readers would lead to a performance loss.
  • The correct configuration of the controller is necessary to ensure proper function of the readers.
  • TWN4 Secustos readers are also equipped with a tamper switch, intended to prevent sabotage. Tampering the reader (activating the tamper switch) does not immediately lead to an alarm. The status of the tamper switch is sent to the controller, which activates appropriate actions by itself.

6 COMPLIANCE STATEMENTS

6.1 GENERAL STATEMENTS

6.1.1 FCC

The TWN4 Secustos family readers comply with the RF exposure requirements for mobile devices (47 CFR 2.1091). However, the devices shall be used in a manner that minimizes the potential for human contact during normal operation.

6.1.2 UNITED KINGDOM

The TWN4 Secustos family readers comply with the requirements of UK legislations and other regulations as listed in the respective UK declaration of conformity. The importer is responsible for providing the importer company's details, including the company's name and a contact address in the United Kingdom, on the packaging.

6.2 TWN4 SECUSTOS MU20

6.2.1 EU

Hereby, ELATEC GmbH declares that TWN4 Secustos MU20 complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at: elatec.me/approvals

6.2.2 FCC

FCC ID: WP5TWN4F32

The device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation (except receivers associated with operation of a licensed radio service and stand-alone devices).

Caution: The Federal Communications Commission (FCC) warns users that changes or modifications to the unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

FCC §15.105 (b)

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

6.2.3 ISED / ISDE CANADA

IC: 7948A-TWN4F32

The device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

6.2.4 UL 294

TWN4 Secustos MU20 has been UL listed as part of the UL 294 certification. However, the reader must be installed and used in accordance with the UL-specific requirements and technical specifications listed in this manual.

6.3 TWN4 SECUSTOS SG30

6.3.1 EU

Hereby, ELATEC GmbH declares that TWN4 Secustos SG30 complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at: elatec.me/approvals

6.3.2 FCC

FCC ID: WP5TWN4F31

The device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation (except receivers associated with operation of a licensed radio service and stand-alone devices).

Caution: The Federal Communications Commission (FCC) warns users that changes or modifications to the unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

FCC §15.105 (b)

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

6.3.3 ISED / ISDE CANADA

IC: 7948A-TWN4F31

The device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

6.3.4 UL 294

TWN4 Secustos SG30 has been UL listed as part of the UL 294 certification. However, the reader must be installed and used in accordance with the UL-specific requirements and technical specifications listed in this manual.

6.4 TWN4 SECUSTOS SQ80

6.4.1 EU

Hereby, ELATEC GmbH declares that TWN4 Secustos SQ80 complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at: elatec.me/approvals

6.4.2 FCC

FCC ID: WP5TWN4F33

The device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation (except receivers associated with operation of a licensed radio service and stand-alone devices).

Caution: The Federal Communications Commission (FCC) warns users that changes or modifications to the unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

FCC §15.105 (b)

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

6.4.3 ISED / ISDE CANADA

IC: 7948A-TWN4F33

The device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

6.4.4 UL 294

TWN4 Secustos SQ80 has been UL listed as part of the UL 294 certification. However, the reader must be installed and used in accordance with the UL-specific requirements and technical specifications listed in this manual.

APPENDIX

A – RELEVANT DOCUMENTATION

ELATEC documentation

  • TWN4 Secustos family, user manual/instructions for use
  • TWN4 Secustos MU20 data sheet
  • TWN4 Secustos SG30 data sheet
  • TWN4 Secustos SQ80 data sheet
  • Secustos product brochure
  • TWN4 AppBlaster User Guide

external documentation

  • Technical documentation related to the installation site
  • Optionally: Technical documentation related to connected devices (e.g., access control unit)

B – TERMS AND ABBREVIATIONS

TERMEXPLANATION
BLEBluetooth Low Energy
EMCelectromagnetic compatibility
ESDelectrostatic discharge
GNDground
HFhigh frequency
LFlow frequency
NFCnear-field communication
OSoperating system
PEprotective earth
RFradio frequency
RFIDradio frequency identification
SARspecific absorption rate
SPDsurge protection device

C – REVISION HISTORY

VERSIONCHANGE DESCRIPTIONEDITION
02New reader models added, Chapters “Cable information” and “Compliance statements” updated07/2025
01First edition05/2025

Contact Information

HQ / EUROPE

ELATEC GmbH
Zeppelinstraße 1
82178 Puchheim, Germany
P +49 89 552 9961 0
F +49 89 552 9961 129
info-rfid@elatec.com

AMERICAS

ELATEC Inc.
1995 SW Martin Hwy.
Palm City, FL 34990, USA
P +1 772 210 2263
F +1 772 382 3749
americas-info@elatec.com

APAC

ELATEC Singapore
1 Scotts Road #21-10 Shaw Centre, Singapore 228208
P +65 9670 4348
apac-info@elatec.com

MIDDLE EAST

ELATEC Middle East Trading FZE
P.O. Box 16868, Dubai, UAE
P +971 50 9322691
middle-east-info@elatec.com

elatec.com

ELATEC reserves the right to change any information or data in this document without prior notice. ELATEC declines all responsibility for the use of this product with any other specification but the one mentioned above. Any additional requirement for a specific customer application has to be validated by the customer themselves at their own responsibility. Where application information is given, it is only advisory and does not form part of the specification. Disclaimer: All names used in this document are registered trademarks of their respective owners.

Models: TWN4, TWN4 RFID Reader Writer, RFID Reader Writer, Reader Writer

File Info : application/pdf, 33 Pages, 1.67MB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html

References

Microsoft Word für Microsoft 365

Related Documents

Preview ELATEC Transponder Matrix: RFID Reader and Module Technology Overview
A comprehensive guide detailing the RFID technologies supported by ELATEC's transponder readers and modules, including product series, features, and compatibility across various standards like NXP and LEGIC.
Preview ELATEC TWN4 BLE Credential Apps and Configuration Guide
This guide details the configuration of ELATEC TWN4 RFID readers for various BLE credential applications, including Mobile Badge BLE NFC, KleverKey, and Safetrust, using the AppBlaster software tool.
Preview ELATEC TWN4 MultiTech 3 LEGIC M BLE Integration Manual
This integration manual from ELATEC provides detailed instructions for integrating the TWN4 MultiTech 3 LEGIC M BLE RFID reader/writer module into host devices, covering product capabilities, safety, and compliance for integrators.
Preview TWN4 USB Front Reader Family User Manual
This user manual provides comprehensive information on the ELATEC TWN4 USB Front Reader family, covering product description, safety information, installation, mode of operation, and compliance statements. It is designed for professional use and details the features and specifications of the TWN4 USB Front Reader and TWN4 USB Front Reader LEGIC.
Preview ELATEC TWN4 Mini Development Kit for RFID Modules
A development kit from ELATEC for integrating and testing TWN4 Mini family RFID modules. Features direct USB communication, status LEDs, and a SAM slot for enhanced security.
Preview ELATEC TWN4 MultiTech 2 LEGIC M LF HF User Manual
User manual for the ELATEC TWN4 MultiTech 2 LEGIC M LF HF RFID reader/encoder, detailing its features, intended use, safety guidelines, technical specifications, operating modes, and compliance declarations.
Preview ELATEC TWN4 MultiTech LEGIC User Manual: RFID Transponder Reader Guide
Comprehensive user manual for the ELATEC TWN4 MultiTech LEGIC RFID transponder reader, covering intended use, safety information, technical data, operation modes, and compliance statements.
Preview ELATEC TWN4 MultiTech 3 M BLE Integration Manual
This integration manual provides detailed instructions and guidelines for integrating the ELATEC TWN4 MultiTech 3 M BLE RFID reader/writer module into host devices, covering safety, compliance, and technical specifications.