Haier Maxi Split Range
This document outlines the specifications and configuration options for the Haier Maxi Split Range of air conditioning units. It details the compatibility between various indoor and outdoor units, their capacities, and the necessary joint kits and adapters for different system configurations.
Indoor and Outdoor Unit Compatibility
Capacity | Phase | Indoor Unit Type | Outdoor Unit Configuration | Indoor Unit Model | Outdoor Unit Model | Required Joint Kit |
---|---|---|---|---|---|---|
10.5 kW | Single Phase | Cassette | 1:2 | AB35S2SC2FA(H) | 1U105S2SS2FA | JOINT KIT FQG-2Y100A + ADAPTER |
Cassette | 1:3 | AB50S2SC2FA(H) | 1U105S2SS2FA | JOINT KIT FQG-3Y200A + ADAPTER | ||
Ceiling Floor | 1:2 | AC35S2SG2FA(H) | 1U105S2SS2FA | JOINT KIT FQG-2Y100A + ADAPTER | ||
Ceiling Floor | 1:3 | AC50S2SG2FA(H) | 1U105S2SS2FA | JOINT KIT FQG-3Y200A + ADAPTER | ||
12.5 kW | Single Phase | Cassette | 1:2 | AB35S2SC2FA(H) | 1U125S2SN2FA | JOINT KIT FQG-2Y200A + ADAPTER |
Cassette | 1:3 | AB50S2SC2FA(H) | 1U125S2SN2FA | JOINT KIT FQG-3Y200A + ADAPTER | ||
Cassette | 1:4 | AB71S2SR1FA(H) | 1U125S2SN2FA | JOINT KIT FQG-4Y200A + ADAPTER | ||
Three Phase | Cassette | 1:2 | AB35S2SC2FA(H) | 1U125S2SN2FB | JOINT KIT FQG-2Y200A + ADAPTER | |
Cassette | 1:3 | AB50S2SC2FA(H) | 1U125S2SN2FB | JOINT KIT FQG-3Y200A + ADAPTER | ||
Cassette | 1:4 | AB71S2SR1FA(H) | 1U125S2SN2FB | JOINT KIT FQG-4Y200A + ADAPTER | ||
14.0 kW | Single Phase | Cassette | 1:2 | AB35S2SC2FA(H) | 1U140S2SN1FA | JOINT KIT FQG-2Y200A + ADAPTER |
Cassette | 1:3 | AB50S2SC2FA(H) | 1U140S2SN1FA | JOINT KIT FQG-3Y200A + ADAPTER | ||
Cassette | 1:4 | AB71S2SR1FA(H) | 1U140S2SN1FA | JOINT KIT FQG-4Y200A + ADAPTER | ||
Three Phase | Cassette | 1:2 | AB35S2SC2FA(H) | 1U140S2SN1FB | JOINT KIT FQG-2Y200A + ADAPTER | |
Cassette | 1:3 | AB50S2SC2FA(H) | 1U140S2SN1FB | JOINT KIT FQG-3Y200A + ADAPTER | ||
Cassette | 1:4 | AB71S2SR1FA(H) | 1U140S2SN1FB | JOINT KIT FQG-4Y200A + ADAPTER | ||
16.0 kW | Three Phase | Cassette | 1:2 | AB35S2SC2FA(H) | 1U160S2SP1FB | JOINT KIT FQG-2Y200A + ADAPTER |
Cassette | 1:3 | AB50S2SC2FA(H) | 1U160S2SP1FB | JOINT KIT FQG-3Y200A + ADAPTER | ||
Cassette | 1:4 | AB71S2SR1FA(H) | 1U160S2SP1FB | JOINT KIT FQG-4Y200A + ADAPTER |
Ducted Units Compatibility
Indoor Unit Type | Outdoor Unit Configuration | Indoor Unit Model | Outdoor Unit Model | Required Joint Kit |
---|---|---|---|---|
Ducted Slim Low Pressure | 1:2 | AD35S2SS1FA(H) | N/A | JOINT KIT FQG-2Y100A + ADAPTER |
1:3 | AD50S2SS1FA(H) | N/A | JOINT KIT FQG-3Y200A + ADAPTER | |
1:4 | AD71S2SS1FA(H) | N/A | JOINT KIT FQG-4Y200A + ADAPTER | |
1:2 | AD35S2SM9FA(H) | N/A | JOINT KIT FQG-2Y200A + ADAPTER | |
1:3 | AD50S2SM9FA(H) | N/A | JOINT KIT FQG-3Y200A + ADAPTER | |
1:4 | AD71S2SM9FA(H) | N/A | JOINT KIT FQG-4Y200A + ADAPTER | |
Ducted Medium Pressure | 1:2 | AD35S2SS1FA(H) | N/A | JOINT KIT FQG-2Y200A + ADAPTER |
1:3 | AD50S2SS1FA(H) | N/A | JOINT KIT FQG-3Y200A + ADAPTER | |
1:4 | AD71S2SS1FA(H) | N/A | JOINT KIT FQG-4Y200A + ADAPTER | |
1:2 | AD35S2SM9FA(H) | N/A | JOINT KIT FQG-2Y200A + ADAPTER | |
1:3 | AD50S2SM9FA(H) | N/A | JOINT KIT FQG-3Y200A + ADAPTER | |
1:4 | AD71S2SM9FA(H) | N/A | JOINT KIT FQG-4Y200A + ADAPTER |
Controllers and Accessories
Wired Controllers (Required for System)
- HW-SA301AFK
- YR-E16B
Central Controllers
- HC-SA164DBT
- YCZ-A004
BMS
- HCM-06
Note: The data presented in this catalogue is indicative and may vary. Please verify accuracy with the supplier before purchasing.