Lumens FW047 Pro AI-Box1 Camconnect Monitor
Specifications
- Product Name: Camconnect Pro (AI-Box1)
- FW Version Supported: v1.5.6 and above
- Connection Interfaces: HDMI, Ethernet
- Power Supply: Power adapter or Power Cord
Product Usage Instructions:
FW Upgrade by OTA:
- Connect the AI-BOX1 with Power, Monitor, and Ethernet.
- Wait for the Firmware update prompt to appear.
- Click on [Update Now] to start the update process.
- The update will start automatically and take around 6 minutes.
- After the update is complete, Camconnect Pro will restart, and you can check the version on the upper right corner.
FW Upgrade by Webpage:
- Prepare the following devices and tools: AI-Box1, PC or Laptop, Monitor, Power adapter/power cord or Ethernet cable, Switch or Router.
- Connect the devices via a switch or router, ensuring IP address ranges are the same.
- Open a browser and enter the IP address of AI-Box1 in the address bar.
- Select [System] > [Setting] > [Maintenance] > [Firmware Update] to choose the firmware file and start updating.
- The download process will take around 5-10 minutes. Monitor the status from HDMI output or webpage.
- After the update process is complete, the system will shut down automatically. Power on or re-plug the power adapter when indicated.
- Login to the webpage again to check the FW version from [About] > [Version].
FW047 – Camconnect Pro(AI-Box1) Firmware Update Manual
There are two methods to upgrade the FW, please find the instruction from following chapters.
- FW Upgrade by OTA
- FW Upgrade by Webpage
- “Browser update MUST unplug/plug power supply” while “internet update, NO NEED to unplug/plug power supply”.
FW Upgrade by OTA
- Tools
Power adapter / Power Cord
HDMI cable Ethernet Cable
Monitor
- FW Update – Video
- Connect the AI-BOX1 with Power, Monitor and Ethernet.
- Please find the following screen.
- The Firmware update will pops up in seconds.
- Please Click [Update Now] to preceed update.
- FW Update will start automatically. (Around 6 minutes taken)
- When FW Update finish, Camconnect Pro will restart and you can check version on upper right corner.
- Connect the AI-BOX1 with Power, Monitor and Ethernet.
FW Upgrade by Webpage
- Device and Tool Preparation
- Please prepare following devices and tools before FW upgrade.
AI-Box1 PC or Laptop Monitor Power adapter and power cord
Ethernet cable and HDMI cable Switch or Router
- Please prepare following devices and tools before FW upgrade.
- Connections
- Connecting via switch or router.
- Make sure the IP address range are the same and if possible avoid multiple opened network interface card on PC you are sending FW from.
- Make sure the IP address range are the same and if possible avoid multiple opened network interface card on PC you are sending FW from.
- Connecting via switch or router.
- FW Update
- Open browser and enter the IP address of AI-Box1 in the address bar.
- You can check the IP address from the [Operation Interface].
- You can check the IP address from the [Operation Interface].
- Select [System]> [Setting]> [Maintenance]> [Firmware Update] to select firmware file and start updating.
- Webpage Update function is available after FW version v1.5.6.
- Webpage Update function is available after FW version v1.5.6.
- FW download starts(around 5-10 minutes taken), please check the status from HDMI output or webpage, don’t unplug the cables and refresh the browser.
- After FW update process is complete, the system will be shut down automatically, please power on or re-plug the power adapter when the HDMI output off and the fan is running at a high speed.
- Note: This message will show around 1-2 minutes, please DO NOT unplug the cables until hearing the fan at a high speed.
- Note: This message will show around 1-2 minutes, please DO NOT unplug the cables until hearing the fan at a high speed.
- Please enter the IP address, login webpage again and check the FW version from [About]> [Version].
- Open browser and enter the IP address of AI-Box1 in the address bar.
FW047 – Camconnect Pro(AI-Box1) Firmware Update Manual
FAQs
Q: How can I check the current firmware version of Camconnect Pro?
A: You can check the FW version on the upper right corner after a successful update for OTA method, or login to the webpage and navigate to [About] > [Version] for Webpage method.
Q: What should I do if the update process encounters an issue or error?
A: If there is an issue during the update process, ensure stable power supply and network connection. Try restarting the update process or contact customer support for assistance.
Documents / Resources
![]() |