Logilink - logo

MP0058 Field Termination Plug
Instruction Manual

MP0058 Field Termination Plug

Logilink MP0058 Field Termination Plug -

  1. Insert cable into nutLogilink MP0058 Field Termination Plug - fig
  2. strip off 1.2 inch(30mm) of cable jacket, fold back braid and drain wire.Logilink MP0058 Field Termination Plug - fig1
  3. paste copper foil on the braid and ground wire and cut off the excess weave and ground wireLogilink MP0058 Field Termination Plug - fig9
  4. Fan out all four twisted pairs, following the color coding label and allocate eachLogilink MP0058 Field Termination Plug - fig8
  5. Across the holder, according the color marks of T568A or T568B or PROFINETLogilink MP0058 Field Termination Plug - fig10
  6. following the color coding label and allocate each conductor into proper slots on wiring cap. Trim the ends of conductors.Logilink MP0058 Field Termination Plug - fig2
  7. Place wiring cap on plugLogilink MP0058 Field Termination Plug - fig3
  8. Close plug cover, make sure the drain wire is in proper contact with grounding clip on plug.Logilink MP0058 Field Termination Plug - fig4
  9. Screw the nut tightLogilink MP0058 Field Termination Plug - fig7
  10. Use angled accessories,Logilink MP0058 Field Termination Plug - fig6
  11. Can achieve 90 degree bends in 4 different directionsLogilink MP0058 Field Termination Plug - fig5
  12. Screw the nut tight