Literature Library KG7T Two Stage Fixed Speed High Efficiency Upflow Horizontal and Downflow Gas Furnaces Owner’s Manual

Contents hide

FEATURES and BENEFITS

  • 100% fired and tested: All units and each component are tested on the manufacturing line. • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
  • 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 second post purge :Increases life of heat exchanger.
  • Hot surface ignitor: Innovative application of an appliance type ignitor with a 20 year history of reliability. Utilizes proven Smartlite® technology.
  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  •  High static blowers: All models equipped with high static blowers.
  • 90 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
  • Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
  • Variable speed blower kit: Upgradable to full variable speed with kit.
  • Convertible: Simple burner orifice and regulator spring
    change for ease of convertibility.
  • Diagnostic lights for easy troubleshooting without counting lashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
  • Integrated control board: Incorporates connections for electronic air cleaner and humidifier.
  • Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
  • Energy Efficient Brushless DC (ECM) Motor: Gives up to 1 SEER point efficiency gain in cooling.
  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

GAS FURNACE COMPONENTS


Upflow/Horizontal Gas Furnace
Downflow Gas Furnace

DIMENSIONS

GAS FURNACE COMPONENTSU pflow/Horizontal Gas Furnace Downflow Gas Furnace DIMENSIONS

*TA Model #’s Dimension “A” Dimension “B” Dimension “C” Dimension “D”
060-23A1 14 1/4 10 3/4 12 5/8 12 7/8
080-24B1 17 1/2 11 3/4 15 7/8 16 1/8
100-24B1
100-35C1  21  14 19 3/8 19 5/8
120-35C1
140-45D1 24 1/2 15 1/4 22 7/8 23 1/8

KG7TA 80+ High Efficiency Upflow/Horizontal Series

*TK Model #’s Dimension “A” Dimension “B” Dimension “C” Dimension “D”
060-23A1 14 1/4 10 3/4 12 5/8 12 7/8
080-24B1 17 1/2 11 3/4 15 7/8 16 1/8
100-24B1
100-35C1  21  14 19 3/8 19 5/8
120-35C1
140-45D1 24 1/2 15 1/4 22 7/8 23 1/8

KG7TK 80+ High Efficiency Downflow SeriesBLOWER PERFORMANCE – KG7TA/TK

G7TA/TK – 80% AFUE, Two Stage Gas Furnace
  Model Number  Heating Input (Btuh) Motor Switch Setting External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise
        *TA/TK-060(C)-*A1         60000 0 0 0 0
1 0 0 0
0 1 0 0 600 555 510
1 1 0 0 705 670 635 600
0 0 1 0 775 57 740 60 705 665
1 0 1 0 900 49 870 51 835 53 800 56 765 58 730 61 695 64 660 67
0 1 1 0 950 47 920 48 890 50 855 52 825 54 795 56 765 58 730 61
1 1 1 0 1000 44 970 46 940 47 910 49 880 51 850 52 820 54 790 56
0 0 0 1 1075 41 1045 43 1015 44 985 45 960 46 925 48 900 49 870 51
1 0 0 1 1110 40 1080 41 1055 42 1025 43 1000 44 975 46 945 47 920 48
0 1 0 1 1170 38 1140 39 1115 40 1090 41 1060 42 1035 43 1010 44 985 45
1 1 0 1 1210 37 1185 38 1160 38 1130 39 1105 40 1080 41 1055 42 1025 43
0 0 1 1 1520 29 1225 36 1200 37 1175 38 1150 39 1120 40 1095 41 1070 42
1 0 1 1 1305 34 1280 35 1255 35 1230 36 1205 37 1180 38 1155 38 1130 39
0 1 1 1 1350 33 1230 36 1305 34 1285 35 1260 35 1240 36 1215 37 1195 37
1 1 1 1 1440 31 1400 32 1365 33 1230 36 1295 36 1255 35 1220 36 1185 38
        *TA/TK-080(C)-*B1         80000 0 0 0 0
1 0 0 0
0 1 0 0
1 1 0 0 725
0 0 1 0 810
1 0 1 0 940 890 845 795 750 700
0 1 1 0 990 60 945 905 860 820 775 735 690
1 1 1 0 1055 56 1015 58 970 930 890 845 805 760
0 0 0 1 1135 52 1095 54 1055 56 1010 59 960 930 890 850
1 0 0 1 1185 50 1145 52 1105 54 1065 56 1030 58 990 60 950 910
0 1 0 1 1250 47 1210 49 1170 51 1135 52 1095 54 1055 56 1020 58 980 60
1 1 0 1 1290 46 1255 47 1220 49 1180 50 1145 52 1110 53 1075 55 1040 57
0 0 1 1 1315 45 1275 46 1240 48 1200 49 1160 51 1120 53 1085 55 1045 57
1 0 1 1 1350 44 1315 45 1280 46 1245 48 1205 49 1170 51 1135 52 1100 54
0 1 1 1 1390 43 1350 44 1315 45 1275 46 1240 48 1200 49 1160 51 1125 53
1 1 1 1 1420 42 1380 43 1345 44 1310 45 1270 47 1235 48 1200 49 1160 51

Notes:

  1.  Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2.  Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3.  Data is shown without filter.
  4.  Temperature rises in the table are approximate. Actual temperature rises may vary.
  5.  Temperature rises that are shaded in grey are not recommended.

BLOWER PERFORMANCE – KG7TA/TK Continued

G7TA/TK – 80% AFUE, Two Stage Gas Furnace
  Model Number  Heating Input (Btuh)  Motor Switch Setting External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise
        *TA100(C)-*B1         100000 0 0 0 0 905 890 805 780
1 0 0 0 980 930 900 835 820 800 715 670
0 1 0 0 1095 1015 980 915 895 870 810 765
1 1 0 0 1160 64 1100 1065 1035 995 940 895 865
0 0 1 0 1230 60 1195 62 1170 1110 1075 1060 995 970
1 0 1 0 1315 56 1275 58 1240 60 1195 62 1160 64 1140 65 1115 1075
0 1 1 0 1345 55 1310 57 1280 58 1250 59 1220 61 1190 62 1140 65 1115
1 1 1 0 1445 51 1390 53 1350 55 1315 56 1280 58 1250 59 1230 60 1185 63
0 0 0 1 1490 50 1430 52 1420 52 1380 54 1340 55 1310 57 1280 58 1275 58
1 0 0 1 1550 48 1510 49 1475 50 1450 51 1420 52 1375 54 1340 55 1325 56
0 1 0 1 1600 46 1270 58 1540 48 1500 49 1475 50 1445 51 1425 52 1385 53
1 1 0 1 1640 45 1605 46 1570 47 1550 48 1525 49 1490 50 1460 51 1430 52
0 0 1 1 1690 44 1665 44 1630 45 1600 46 1570 47 1550 48 1515 49 1490 50
1 0 1 1 1755 42 1730 43 1680 44 1660 45 1640 45 1610 46 1575 47 1550 48
0 1 1 1 1805 41 1770 42 1740 43 1715 43 1690 44 1655 45 1645 45 1605 46
1 1 1 1 1860 40 1825 41 1790 41 1765 42 1745 42 1710 43 1695 44 1660 45
        *TA/TK-100(C)-*C1         100000 0 0 0 0 1125 66 1040 960
1 0 0 0 1205 61 1120 1040 960
0 1 0 0 1305 57 1225 60 1150 64 1070 995 915
1 1 0 0 1430 52 1350 55 1270 58 1190 62 1110 1030 950 865
0 0 1 0 1525 49 1450 51 1375 54 1300 57 1225 60 1150 64 1075 1000
1 0 1 0 1620 46 1540 48 1465 51 1390 53 1315 56 1240 60 1165 64 1090
0 1 1 0 1695 44 1620 46 1545 48 1465 51 1390 53 1315 56 1235 60 1160 64
1 1 1 0 1770 42 1700 44 1630 45 1555 48 1485 50 1410 53 1340 55 1265 59
0 0 0 1 1875 40 1805 41 1730 43 1655 45 1580 47 1510 49 1435 52 1340 55
1 0 0 1 1905 39 1840 40 1775 42 1710 43 1640 45 1575 47 1510 49 1445 51
0 1 0 1 1980 37 1910 39 1845 40 1780 42 1715 43 1650 45 1580 47 1515 49
1 1 0 1 2025 37 1960 38 1895 39 1830 40 1765 42 1700 44 1635 45 1570 47
0 0 1 1 2085 36 2025 37 1960 38 1900 39 1840 40 1775 42 1715 43 1655 45
1 0 1 1 2135 35 2070 36 2010 37 1945 38 1880 39 1815 41 1750 42 1685 44
0 1 1 1 2200 34 2145 35 2090 35 2035 36 1980 37 1925 38 1870 40 1820 41
1 1 1 1 2280 32 2225 27 2170 34 2115 35 2065 22 2010 37 1955 38 1900 39

Notes:

  1.  Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2. Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Temperature rises that are shaded in grey are not recommended.

BLOWER PERFORMANCE – KG7TA/TK Continued

 

Model Number

Heating Input (Btuh)

Motor Switch Setting

External Static Pressure (in.w.c.)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

1/5

2/6

3/7

4/8

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

 

 

 

 

 

 

 

 

*TA/TK-120(C)-*C1

 

 

 

 

 

 

 

 

120000

0

0

0

0

1125

1040

1

0

0

0

1205

1120

1040

0

1

0

0

1305

1225

1150

1070

1

1

0

0

1430

62

1350

1270

1190

1110

1030

0

0

1

0

1525

58

1450

61

1375

65

1300

1225

1150

1075

1000

1

0

1

0

1620

55

1540

58

1465

61

1390

64

1315

1240

1165

1090

0

1

1

0

1695

52

1620

55

1545

58

1465

61

1390

64

1315

1235

1160

1

1

1

0

1770

50

1700

52

1630

55

1555

57

1485

60

1410

63

1340

66

1265

0

0

0

1

1875

47

1805

49

1730

51

1655

54

1580

56

1510

59

1435

62

1340

66

1

0

0

1

1905

47

1840

48

1775

50

1710

52

1640

54

1575

56

1510

59

1445

62

0

1

0

1

1980

45

1910

47

1845

48

1780

50

1715

52

1650

54

1580

56

1515

59

1

1

0

1

2025

44

1960

45

1895

47

1830

49

1765

50

1700

52

1635

54

1570

57

0

0

1

1

2085

43

2025

44

1960

45

1900

47

1840

48

1775

50

1715

52

1655

54

1

0

1

1

2135

42

2070

43

2010

44

1945

46

1880

47

1815

49

1750

51

1685

53

0

1

1

1

2200

40

2145

41

2090

43

2035

44

1980

45

1925

46

1870

48

1820

49

1

1

1

1

2280

39

2225

40

2170

41

2115

42

2065

43

2010

44

1955

45

1900

47

 

 

 

 

 

 

 

 

*TA/TK-140(C)-*D1

 

 

 

 

 

 

 

 

140000

0

0

0

0

1395

1350

1305

1260

1210

1165

1

0

0

0

1465

1420

1375

1330

1290

1245

1200

0

1

0

0

1555

67

1510

69

1470

1425

1380

1340

1295

1250

1

1

0

0

1625

64

1585

65

1540

67

1500

69

1460

1415

1375

1335

0

0

1

0

1690

61

1650

63

1610

64

1570

66

1530

68

1485

70

1445

1405

1

0

1

0

1760

59

1715

60

1670

62

1625

64

1575

66

1530

68

1485

70

1440

0

1

1

0

1835

57

1790

58

1745

59

1695

61

1650

63

1605

65

1555

67

1510

69

1

1

1

0

1885

55

1840

56

1790

58

1745

59

1700

61

1655

63

1610

64

1565

66

0

0

0

1

1945

53

1900

55

1850

56

1805

57

1760

59

1710

61

1665

62

1620

64

1

0

0

1

1950

53

1905

54

1860

56

1820

57

1775

58

1735

60

1690

61

1650

63

0

1

0

1

2075

50

2030

51

1990

52

1945

53

1900

55

1855

56

1810

57

1770

59

1

1

0

1

2125

49

2085

50

2040

51

2000

52

1955

53

1910

54

1870

55

1825

57

0

0

1

1

2170

48

2130

49

2090

50

2045

51

2005

52

1965

53

1925

54

1880

55

1

0

1

1

2215

47

2180

48

2140

48

2105

49

2070

50

2035

51

2000

52

1965

53

0

1

1

1

2225

47

2165

48

2100

49

2040

51

1

1

1

1

2170

48

2120

49

2065

50

Notes:

  1.  Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2.  Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3.  Data is shown without filter.
  4.  Temperature rises in the table are approximate. Actual temperature rises may vary.
  5.  Temperature rises that are shaded in grey are not recommended.

MODEL IDENTIFICATION CODE

SPECIFICATIONS

KG7TA/TK MODEL NUMBERS  060C-23A1  080C-24B1  100C-24B1  100C-35C1  120C-35C1  140C-45D1
Input – Btuh (a) 60,000 / 39,000 80,000 / 52,000 100,000 / 65,000 100,000 / 65,000 120,000 / 78,000 140,000 / 91,000
Heating Capacity – Btuh 48,000 / 31,200 64,000 / 41,600 80,000 / 52,600 80,000 / 52,600 96,000 / 62,400 112,000 / 72,800
AFUE 80.0 80.0 80.0 80.0 80.0 80.0
Blower D x W 10 x 6 11 x 8 11 x 8 11 x 10 11 x 10 11 x 10
Motor H.P. – Speed – Type 1/2 BLDC 1/2 BLDC 1/2 BLDC 3/4 BLDC 3/4 BLDC 1 BLDC
Motor FLA 6.2 6.2 8.7 8.7 8.7 11.7
Rated Ext. SP – In. W.C. 0.5 0.5 0.5 0.5 0.5 0.5
Temperature Rise Range – ºF 25-55 30-60 30-60 35-65 35-65 40-70
Shipping Weights – TA 104lbs 116lbs 120lbs 135lbs 135lbs 154lbs
Shipping Weights – TK 104lbs 116lbs 116lbs 135lbs 140lbs 146lbs

All models are 115 V, 60 HZ. Gas connections are 1/2″ N.P.T. AFUE= Annual Fuel Utilization Efficiency

ACCESSORIES

KG7TA/TK KITS
Description SKU
Fixed Speed to Variable Speed 904880
“A” Cabinet Downflow Sub Base Kit 902974
“B”, “C”, “D” Cabinet Downflow Sub Base Kit 904911
U.S. LP Conversion Kit (0 to 10,000 ft.) 905028
Canada LP Conversion Kit (0 to 4,500 ft.) 905029
Bottom Return Filter 20 per Box, “B” Cabinet 904916
Bottom Return Filter 20 per Box, “D” Cabinet 904918
Side Return Filter Kit 541036

GENERAL TERMS OF LIMITED WARRANTY 

Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.

For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations

subject to change without notice and without incurring obligations. Printed in U.S.A (06/2017

Documents / Resources

Literature Library KG7T Two Stage Fixed Speed High Efficiency Upflow Horizontal and Downflow Gas Furnaces [pdf] Owner's Manual
KG7T Two Stage Fixed Speed High Efficiency Upflow Horizontal and Downflow Gas Furnaces, KG7T, Two Stage Fixed Speed High Efficiency Upflow Horizontal and Downflow Gas Furnaces, Efficiency Upflow Horizontal and Downflow Gas Furnaces, Horizontal and Downflow Gas Furnaces, Downflow Gas Furnaces

References

Leave a comment

Your email address will not be published. Required fields are marked *