UB-H2S-I1 Wifi Temperature Sensor
“
Product Specifications
- Model: UB-H2S-I1
- Power Supply: DC 10~30V
- Max Current: 917mA@12V
- Measuring Range: 0~100ppm
- Accuracy: -20~50°C, 15~90%RH
- Resolution: Audio
- Warm-up Time: 3m
- Response Time: RS485 Modbus RTU Protocol
- Working Environment: RS485 Address
- Connector Cable Length: 3m
- Communication Protocol: RS485 Modbus RTU
Protocol - Baud Rate: 1200 bit/s, 2400 bit/s, 4800 bit/s,
9600 bit/s (default), 19200 bit/s
Product Usage Instructions
Wiring Instruction
Follow the wiring diagram provided in the user manual to
correctly connect the device to the power supply and communication
interface.
Communication Protocols
Configure the communication parameters as follows:
- Coding System: Data Bit, Parity Checking Bit, Stop Bit, Error
Checking, Baud Rate - Data Frame Format: Modbus-RTU protocol with specific structure
details as mentioned in the manual. - Register Address: Address values and corresponding descriptions
are provided for reference.
Usage Precautions
- Avoid installation in strong convective air environments.
- Avoid contact with organic solvents, paints, chemicals, oils,
and highly concentrated gases. - Avoid prolonged exposure to corrosive gases as they can damage
the sensor. - Avoid long-term storage in high concentrations of organic or
alkaline gases.
Frequently Asked Questions (FAQ)
Q: What is the recommended power supply for the device?
A: The device operates on a DC power supply ranging from 10V to
30V.
Q: How can I adjust the device on-site?
A: The device comes with a level and adjusting handwheel for
easy on-site adjustments.
Q: What is the communication protocol used by the device?
A: The device uses RS485 Modbus RTU Protocol for
communication.
“`
Product Introduction
The sensor adopts professional hydrogen sulphide concentration sensor probe as the core detecting device; it has the characteristics of wide measuring range, high precision, good linearity, good versatility, easy to use, easy to install, long transmission distance and moderate price.
Use Case Scenarios Widely used in chemical plants and other gas leakage detection.
Features 1. High precision photoreceptor, high absorption in the full spectrum range. 2. Comes with level and adjusting handwheel, easy to adjust on site. 3. Highly transparent dust cover with good sensitivity and special surface treatment to prevent dust
adsorption.
Product Specifications
Model Power Supply Max Current Measuring Range
Accuracy Resolution Warm-up Time Response Time Working Environment Connector Cable Length Communication Protocol RS485 Address Baud Rate
Specifications UB-H2S-I1 DC 10~30V
917mA@12V 0~100ppm
±2ppm±10% 1ppm 5 min 35 s
-20~50, 15~90%RH Audio 3m
RS485 Modbus RTU Protocol 0xC9
1200 bit/s,2400 bit/s, 4800 bit/s, 9600 bit/s (default), 19200 bit/s
Wiring Instruction
Communication protocols
1. Communication basic parameters
Coding System Data Bit
Parity Checking Bit Stop Bit
Error Checking Baud Rate
Communication Basic Parameter 8bit binary 8 bits none 1 bit CRC Check
1200 bit/s, 2400 bit/s, 4800 bit/s, 9600 bit/s (default), 19200 bit/s
2. Data Frame Format
The Modbus-RTU communication protocol is used in the following format:
Initial structure 4 bytes in time.
Address code: 1 byte, default 0xC9.
Function code: 1 byte, support function code 0x03 (read only) and 0x06 (read/write).
Data area: N bytes, 16-bit data, high byte comes first.
Error check: 16-bit CRC code.
End structure 4 bytes of time.
Request
Slave Address
Function Code Register Address No. of Registers
CRC LSB
CRC MSB
1 byte
1 byte
2 bytes
2 bytes
1 byte
1 byte
Response
Slave Address Function Code No. of Bytes Content 1 Content 1
…
Content n
CRC
1 byte
1 byte
1 byte
2 bytes
2 bytes
…
2 bytes
2 bytes
3. Register Address
Address 0x0000 0x07D0
0x07D1
Content H2S value Address
Baud Rate
Register Address
Register Length Function Code
1
03
1
03/06
1
03/06
Description of definitions Integer 1255
0:2400, 1:4800, 2:9600, 3:19200, 4:38400, 5:57600, 6:115200, 7:1200
NOTE 1. Do not install the equipment in a strong convective air environment. 2. Avoid contact with organic solvents (including silicone and other adhesives), paints, chemicals, oils
and highly concentrated gases. 3. The device should not be used for a long time in the environment containing corrosive gases,
corrosive gases will damage the sensor. 4. Do not place the device for a long time in a high concentration of organic gases, long-term
placement will lead to sensor zero point drift, and slow recovery. 5. Prohibit long time storage and use in high concentration alkaline gas.
Documents / Resources
![]() |