ESP-LXIVM Series Controllers

Specifications

  • Product: ESP-LXIVM Series Controllers
  • Manufacturer: Rain Bird Corporation
  • Model: ESP-LXIVM
  • Compliance: FCC, IC Canada, CE

Product Usage Instructions

1. Field Device Installation

Follow the below steps for proper installation of the ESP-LXIVM
Series Controllers:

  1. Ensure all valve wires are separate and insulated to prevent
    electrical shorts.
  2. Connect the 2-wire cable as per the Typical IVM-OUT Wiring
    diagram in the manual.
  3. Refer to the Regulatory Information section for compliance
    statements and unique identifiers.

2. Safety Information

WARNING: Special precautions must be taken to
prevent electrical shorts and fire hazards when installing the
controller near other wires.

Separate and insulate all conductors carefully, ensuring no
contact between valve wires and other power sources.

FAQ

Q: What should I do if there is interference with the
device?

A: If interference occurs, ensure that the device is not causing
harmful interference and can accept any interference received.

Q: How can I ensure compliance with regulations?

A: Follow the installation guidelines provided and refer to the
Declaration of Conformity to ensure compliance with FCC, IC Canada,
and CE regulations.

“`

ESP-LXIVM Series Controllers
Field Device Installation Guide

B CiCnnNB ofvooftOA niIaeioFrtVIdtTlwmeoIVvaiCVMEctsirweicasI:rooMCMV(teftr-ib1OcMnunCreioMO.-ooeontUOtcomnt-ahn.um-UxoreOnTnkOUoe.remclTenpeeotTUttlUoceeacm2vsvtTttttcraruaht-oai)ToethtbWltretilvonuheteoolvtehe(fbdbihene2rOte2leelwteh.sa-emrh-dWraecusWiDwecethtkadhiodtCtir/nioo/rteDwtnpwnehuaohlPCltonheaftheucraaitnDdiaaniotccDttltevbghaehCtRlbCeult.DidaslecnolsartiaalehetngrrcasernitrvikttpimnBcpocvsiewgahfciohreorodiededliididcrenrnddssweinvegogfiwsmcitiaoilnc)ireaslioosieaovrdnonoeennterooliaelaesobbteoinc.lh-dnlhenna3etscoh,urtIkeeiVhsddMeesd.-
icrcrUaoiaTgnsOnnMheacdnUitaaosieTsoxuniconniastlmlyecinesoluWndyusnesmodsiCtrtieeidst2ocosm0louwoptm.ssahirpreddebel-aisi(i2cnneme(-e.2sWgNatkd2.agiirtSwliOeelnsoei.ftPrldT)ooee.arnIItyVlChaeooMln.iEludIg-wmr)OtcsihprUhoirnbTnaogeltpwlrtboewirreleleew4e(r28inro4iinIrnVign.M.)-

Valve

A

Box

IVM-OUT
B

LatvNcaholivnne-gRwSaioitnhleBDniroCdid

2-Wire Cable
Typical IVM-OUT Wiring

C AlEloxLwterna3gCftath.b(l1em)

Regulatory Information
Federal Communications Commission
Supplier’s Declaration of Conformity
47 CFR § 2.1077 Compliance Information
Unique Identifier: ESPLXIVM, ESPLXIVMP, LXIVMFP, LXIVMPFP, LXIVMSOL, LXIVMOUT, LXIVMSEN, LXIVMSD
Responsible Party ­ U.S. Contact Information
Rain Bird Corporation 9491 Ridgehaven Court San Diego, CA 92123 USA
www.rainbird.com
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.

IC Canada Statement The Class B apparatus meets all requirements of the Canadian ISED (formerly IC) regulations – CAN ICES-3 (B)/NMB-3 (B).
Cet appareil de classe B respecte toutes les exigences de la réglementation canadienne ISED (anciennement IC)- CAN ICES-3 (B)/NMB-3 (B).
Waste Electrical and Electronic Equipment (WEEE) As a hardware manufacturer, Rain Bird has met its national obligations to the EU WEEE Directive by registering in those countries to which Rain Bird is an importer. Rain Bird has also elected to join WEEE Compliance Schemes in some countries to help manage customer returns at end of life.
Certifications
· cULus, CE, NOM, RCM, IRAM, INMETRO, NRCS, SABS, KC

2 ESP-LXIVM Series Controllers

DECLARATION OF CONFORMITY

Rain Bird Corporaon hereby declares that the following irrigaon controllers and accessories are CE compliant.

IESPLXIVM, IESPLXIVMP, ILXIVMEU, ILXIVMPEU, LXIVMSOL, LXIVMOUT, LXIVMSEN, LXIVMSD, LXIVMPFP*, LXIVMFP*, and LXIVM2WMOD* (*Spare part sold separately – obtained compliance with the controller IESPLXIVM)

This declaraon of conformity is issued under the sole responsibility of the manufacturer. The object of the declaraon described above is in conformity with the relevant Union harmonizaon legislaon, and the references to the relevant harmonized standards used or to other technical specificaons in relaon to which conformity is declared are listed below:

Electromagnec Compability (EMC) Direcve 2014/30/EU · EN 55014-1:2006 + A2:2011
· EN 55014-2:1997 + A1:2001 + A2:2008 Low Voltage (LVD) Direcve 2014/35/EU
· EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 including · IEC 60335-1:2010, and EN 62233:2008 + AC:2008
· IEC 60335-1 Edion 5.2: 2010 +A1: 2013 +A2: 2016 Restricon of the use of certain Hazardous Substances (RoHS) Direcve 2011/65/EU
· EN 50581:2012

Place: Signature:
Full Name: Posion: Date:

San Diego, CA
Roger S. Neitzel Plant and Program Manager January 8, 2020

Rain Bird Corporaon 970 W. Sierra Madre Ave. Azusa, California 91702, USA
Phone: 626-812-3400 Fax: 626-812-3411
2020 Rain Bird Corporaon Registered Trademark of Rain Bird Corporaon

Rain Bird Internaonal, Inc. 1000 West Sierra Madre Ave.
Azusa, CA 91702, USA Phone: 626-963-9311
Fax: 626-852-7343

Rain Bird Europe 240 Rue René Descartes ­ Le Clamar Bât. A
13290 Aix En Provence, France Phone: (33) 4 42 24 44 61 Fax: (33) 4 42 24 24 72
P/N: 690865-01 REV. 08JA20

ESP-LXIVM Series Controllers 3

Safety Information
CWARNING
Special precautions must be taken when valve wires (also known as station or solenoid wires) are located adjacent to, or share a conduit with other wires, such as those used for landscape lighting, other “low voltage” systems or other “high voltage” power.
Separate and insulate all conductors carefully, taking care not to damage wire insulation during installation. An electrical “short” (contact) between the valve wires and another power source can damage the controller and create a fire hazard.
All electrical connections and wiring runs must comply with local building codes. Some local codes require that only a licensed or certified electrician can install power. Only professional personnel should install the controller. Check your local building codes for guidance.

CCAUTION
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capacity, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
If the supply cord of ILXIVMAU or ILXIVMAUP is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Replace with the following: Flexible supply cord H05VVF, minimum wire size of 0.75 mm^2 (18 AWG). For direct connection wiring: Minimum wiring size is 0.75 mm^2 (18 AWG).
For controllers not provided with a supply cord, the fixed installation must include a disconnecting device for all three poles suitable for overvoltage category III protection.

NOTICE
Use only Rain Bird approved accessory devices. Changes or modifications not expressly approved by Rain Bird could void the user’s authority to operate the equipment. Unapproved devices may damage the controller and void the warranty. For a list of compatible devices go to: www.rainbird.com
Date and time are retained by a lithium battery which must be disposed of in accordance with local regulations.
Model, serial number, supply rate and fabrication date are located on the back of swing panel.
Power supply for countries with 120V Input: 120 V ac 60 Hz 0.5A Output: 26.5 V ac 60 Hz 1.9A`

4 ESP-LXIVM Series Controllers

ESP-LXIVM Series Controllers
Field Device Installation Guide
2-Wire Device Field Connections ………………………………… 6
Gather Installation Tools ……………………………………………………………………… 6 Wiring Connections …………………………………………………………………………….. 6 Outdoor Installation with Direct Wiring………………………………………………………….. 6 Field Wiring Connections ………………………………………………………………………………. 7
Connect devices to the 2-Wire path. ……………………………………………………………………… 7 Installation …………………………………………………………………………………………. 8 2-Wire Address Labels …………………………………………………………………………………… 8 IVM-SOL Installation ……………………………………………………………………………………… 9
Connect IVM-SOL to a Valve ………………………………………………………………………………….. 10 Connect IVM-SOL to a Master Valve ………………………………………………………………………. 10 IVM-OUT (Output Device)………………………………………………………………………………. 11 IVM-SEN (Sensor Device) ……………………………………………………………………………….. 12 Connect Weather Sensors ……………………………………………………………………………………… 12 IVM-SD (Surge Device)…………………………………………………………………………………… 13 Pump Start Relay…………………………………………………………………………………………… 14 Connect 2-Wire (MAXI Cable) From Field Devices ………………………………….. 15 Connect Local Weather Sensors……………………………………………………………. 15
ESP-LXIVM Series Controllers 5

2-Wire Device Field Connections
Gather Installation Tools
Before beginning installation, gather together the following tools and materials:
LLLineman’s pliers L#14 AWG MAXI Cable
bare ground wire
LWC20 waterproof wire connectors and wire nuts (provided) Rain Bird® 2-Wire stripper
Wiring Connections
Outdoor Installation with Direct Wiring
CWARNING
Electric shock can cause severe injury or death. Make sure power supply is turned OFF before connecting power wires. Ground wire must be connected to provide electrical surge protection. Permanently mounted conduit shall be used for connecting main voltage to the controller. Do not route valve wires through the same opening as power wires.

Wiring Connections

120 VAC (US) 230 VAC (International)

Black supply wire (hot) to Brown supply wire (hot) to the black transformer wire the brown transformer wire

White supply wire (neutral) Blue supply wire (neutral) to to the white transformer the blue transformer wire wire

Green supply wire (ground) to the green transformer wire

Green-with-yellow-stripe supply wire (ground) to the green-with-yellow-stripe transformer wire

ARoute the three external power source wires through
the conduit opening at the bottom of the unit and into the wiring compartment.
BUsing the provided wire nuts, connect the external
power source wires (two power and one ground) to the transformer connection wires inside the wiring compartment.

B

6 ESP-LXIVM Series Controllers

Field Wiring Connections
Connect devices to the 2-Wire path.

It is recommended to use the Rain

Bird 2-Wire Stripper tool to remove the outer MAXI Cable jacket without damaging the inner insulation.

Rain Bird 2-Wire Stripper

BNOTE: To avoid damaging the wiring, tools such as utility, pocket, carpet, box cutter knives or Romex strip-

pers should not be used to strip wires.

NOTICE
Rain Bird requires the use of 14 gauge AWG MAXI Cable (double-jacketed, 2-Wire conductor).
Always place 2-Wire Devices and connections inside a valve box. Assure that the wiring copper conductors are not exposed after installation.

ACarefully score approximately 6 in (15,24 cm) of the
AWG MAXI Cable’s outer jacket . Gently flex the cable to expose the portion to be removed and to reveal the 2 inner wires. Then trim away the excess of the outer jacket.
BNOTE: It may be necessary to remove the outer jacket in two or more sections.
A

BStrip away approximately 5/8 in (1,58 cm) of insulation
from the ends of the two inner wires.

No nicks or cuts to inside wire

No scratches
B

6 in (15,24 cm)

5/8 in (1,58 cm)

CRemove the pre-cut insulation from the ends of the
wires on the 2-Wire device. Connect the device wires to the 2-Wire path using linesman’s pliers to twist the ends together.
C

NOTICE
Wire colors must be paired red to red and black to black in order to maintain polarity when completing wire splices.

ESP-LXIVM Series Controllers 7

DInsert the connected wires into the provided wire-nuts
and twist to secure.
EInsert the wire-nut all the way into the WC20 connec-
tor. Position wires on side of the connector as shown and then snap the cap shut.
D
E

Installation
2-Wire Address Labels
Before installing the 2-Wire Device, apply your 2-Wire Device barcode labels to the appropriate fields on the Programming Guide.
BNOTE: See the ESP-LXIVM Programming Guide that came with your controller.
ACarefully peel off the station, master valve, flow or
weather sensor device barcode label.
BApply the 2-Wire Device address labels in the appropri-
ate fields on the Programming Guide.
BNOTE: Do not remove the label from the carrier attached to the wire.

Completed Wire Splice

40005

Scan the QR code to see a video on how to make 2-Wire cable connections.

40005 40005

8 ESP-LXIVM Series Controllers

IVM-SOL Installation AUse pressure sprayer to clean equipment. BCheck that O-rings are free from damage or debris. CAttach IVM-SOL hand-tight (with no water pressure).
BNOTE: It’s normal to hear a brief ratcheting sound during installation of the IVM-SOL on a valve.
ESP-LXIVM Series Controllers 9

Connect IVM-SOL to a Valve
AConnect the red and black wires on the
IVM-SOL to the 2-Wire Path.
BFor future troubleshooting or modifica-
tions, it is recommended to leave an additional 3 feet (1 meter) of 2-Wire cable stored in each valve box location.
BNOTE: If the valve is NOT at the end of the 2-Wire Path then make a three-way splice; the red wire from the valve module to the two red wires of the 2-Wire Path; then splice the valve module black wire to the two black wires of the 2-Wire Path.
NOTICE
Use only WC20 splice kits for all wiring connections to the 2-Wire Path. Improper wiring can cause serious damage to your controller or irrigation system.
Connect IVM-SOL to a Master Valve
Up to 5 master valves can be connected to the 2-Wire path of the ESP-LXIVM controller and up to 10 master valves for the LX-IVM Pro controller. IVM-SOL can be used for both station and master valves. Master valves are connected using the same processes as described previously.
BNOTE: Be sure to attach the barcode labels to the Programming Guide as a Master Valve instead of a Station.

NOTICE
If retro-fitting, do not use TBOS (Battery Operated System) solenoids or decoders in the ESP-LXIVM system. Ensure that all decoders are disconnected from the 2-Wire path.

Valve

A

Box

IVM-SOL

2-Wire Cable

Allow 3 ft. (1 m)
B Extra Cable
Length

Typical IVM-SOL Valve Wiring

10 ESP-LXIVM Series Controllers

IVM-OUT (Output Device)
IVM-OUT 2-Wire control devices can be used to control valves with DC latching solenoids.
AConnect the red and black wires on the IVM-
OUT to the 2-Wire Path.
BConnect the red/white striped wire on the
IVM-OUT to the DC latching solenoid red wire. Connect the black/white striped wire on the IVM-OUT to the DC latching solenoid black wire.
CFor future troubleshooting or modifications,
it is recommended to leave an additional 3 feet (1 meter) of 2-Wire cable stored in each valve box location.
BNOTE: Make sure that the DC latching solenoid is compatible with non Rain Bird valves. Contact the valve manufacturer for more information.
NOTICE
Maximum combined wire length between IVMOUT and its load (e.g. Solenoid) shall be 48 in. This includes pre-installed IVM-OUT wire (24 in.) and solenoid wires (22 in.).
Use only WC20 splice kits for all wiring connections to the 2-Wire Path. Improper wiring can cause serious damage to your controller or irrigation system.

Valve Box
A

IVM-OUT
B

Non-Rain Bird valve with DC Latching Solenoid

2-Wire Cable
Typical IVM-OUT Wiring

Allow 3 ft. (1 m)
C Extra Cable
Length

ESP-LXIVM Series Controllers 11

IVM-SEN (Sensor Device)
Flow sensors are connected to the 2-Wire Path via IVM-SEN 2-Wire devices. The ESP-LXIVM controller can support up to 5 flow sensors and the LX-IVM Pro controller can support up to 10 flow sensors. Connect Flow Sensors
AInstall flow sensors into your irrigation pip-
ing system at each point of connection to the water supply (water meter or pump).
NOTICE
For optimum performance and flow sensing, flow sensors should be installed a minimum of 10 pipe diameters in length on the upstream (supply) side and a least 5 pipe diameters in length on the downstream (delivery) side before making any transitions in pipe size/ direction or away from the master valve.
BConnect the red and black wires on the
IVM-SEN to the 2-Wire Path.
CConnect the red/white striped wire on IVM-
SEN to the flow sensor red wire Connect the black/white striped wire on IVM-SEN to the flow sensor black wire.
BNOTE: Be sure to follow all instructions included with the flow sensor.
DFor future troubleshooting or modifica-
tions, it is recommended to leave an additional 3 feet (1 meter) of 2-Wire cable stored in each valve box location.
12 ESP-LXIVM Series Controllers

NOTICE
Use only WC20 splice kits for all wiring connections to the 2-Wire Path. Improper wiring can cause serious damage to your controller or irrigation system.

Valve Box
B

IVM-SEN
C

FS-Series Flow Sensor

A

2-Wire Cable

Allow 3 ft. (1 m)
D Extra Cable
Length

Typical IVM-SEN Flow Sensor Wiring

Connect Weather Sensors
In addition to flow sensors, the LX-IVM can also support three weather sensors connected to the 2-Wire Path via an IVM-SEN. The LX-IVM Pro controller supports seven 2-Wire Path weather sensors. Weather sensors are connected to the LX-IVM Sensor input in the same way as the flow sensor.

IVM-SD (Surge Device)
The IVM-SD provides surge protection for the ESP-LXIVM controller and the 2-Wire path.
The ESP-LXIVM controller and the 2-Wire path must be properly surge protected and grounded. Doing so can help prevent damage to the controller and irrigation system and also significantly reduce troubleshooting, repair time and expense. Failure to do so could result in failure of your controller and voiding the warranty.
AConnect the red and black wires on the
IVM-SD to the 2-Wire Path
BConnect the green wires from the IVM-SD
to the grounding rod or plate
CFor future troubleshooting or modifica-
tions, its is recommended to leave an additional 3 feet of 2-Wire cable stores in each valve box location.
NOTICE
Use only WC20 splice kits for all wiring connections to the 2-Wire Path. Improper wiring can cause serious damage to your controller or irrigation system.
One IVM-SD is required every 500 feet or every 15 field devices.
IVM-SD shall also be spliced into each 2-Wire Path immediately next to the controller and at the termination of each wire path.

Valve Box
A

IVM-SOL IVM-SD
B

2-Wire Cable

C Allow 3 ft. (1 m)
Extra Cable
Length

Typical IVM-SD Wiring

ESP-LXIVM Series Controllers 13

Pump Start Relay
IVM-OUT 2-Wire Control Devices can control pump start relays that have a DC latching input coil.
AConnect the red IVM-OUT wire to the red
wire on the 2-Wire path. Then connect the black IVM-OUT wire to the black wire on the 2-Wire path.
BConnect the red and white IVM-OUT wire
to the red wire of the DC Latching Relay. Connect the black and white IVM-OUT wire to the black wire of the DC Latching Relay.
CFollow your Pump Start Relay wiring
instructions to connect input power and pump.
DFor future troubleshooting or modifi-
cations, it is recommended to leave an additional 3 feet (1 meter) of 2-Wire cable stored in each valve box location.
NOTICE
Use only WC20 splice kits for all wiring connections to the 2-Wire Path. Improper wiring can cause serious damage to your controller or irrigation system and work must be performed by licensed electrician.
CWARNING
All electrical connections and wiring runs must comply with local building codes. Some local codes require that only a licensed or certified electrician can install power. Only professional personnel should install the controller. Check your local building codes for guidance.
14 ESP-LXIVM Series Controllers

Pump Start with DC Latching Relay Model Nos. PSR110-IVM and PSR220-IVM

C
Input Power

To Pump

Valve

Box

A

IVM-OUT

B

D Allow 3 ft. (1 m)
Extra Cable Length
Typical IVM-OUT Pump Start Relay Wiring

Connect 2-Wire (MAXI Cable) From Field Devices
You can connect up to 4 pairs of 2 -Wires (MAXI Cable) from the field devices back to the ESP-LXIVM controller.
BNOTE: Make sure the screws are all unscrewed all the way out (while remaining in the module)
AConnect the Red Wire from the MAXI Cable to the
Terminal with “R” marking
BConnect the Black Wire from the MAXI Cable to the
Terminal with “B” marking
CTighten the screw
BNOTE: The four pair of wires can be either in a Star pattern or a Loop pattern. For details refer to the 2-Wire Path overview section in the ESP-LXIVM user manual.

Connect Local Weather Sensors
ESP-LXIVM can also accept input from a single weather sensor wired directly in to the controller.
BNOTE: Follow the sensor manufacturer’s instructions to correctly install and make wire connections to the sensor.
DRun continuous sensor wires from the weather sensor
to the ESP-LXIVM controller.
ERemove the yellow jumper wire (if present). Connect
the sensor wires to the sensor (Sen) and common (C) inputs.
NOTICE
Do not remove the yellow jumper wire unless collecting a rain sensor.
BNOTE: Ensure that the configuration for your controller and irrigation programs are set up correctly for your sensor.

E B
A RB RB

ESP-LXIVM Series Controllers 15

Rain Bird Corporation 6991 East Southpoint Road
Tucson, AZ 85756 USA
Tel: 520-741-6100
Rain Bird Turkey Çamlik Mh. Dinç Sokak Sk. No.4 D:59-60
34760 Ümraniye, stanbul TÜRKIYE
Tel: (90) 216 443 75 23 rbt@rainbird.eu
www.rainbird.com.tr
Rain Bird Ibérica S.A. C/ Valentín Beato, 22 2ª Izq. fdo
28037 Madrid ESPAÑA
Tel: (34) 91 632 48 10 rbib@rainbird.eu · www.rainbird.es
portugal@rainbird.eu www.rainbird.pt

Rain Bird Corporation 970 W. Sierra Madre Ave.
Azusa, CA 91702 USA
Tel: 626-812-3400
Rain Bird Europe SNC Rain Bird France SNC 240 rue René Descartes Bâtiment A, Parc Le Clamar
BP 40072 13792 AIX-EN-PROVENCE CEDEX 3
FRANCE Tel: (33) 4 42 24 44 61 rbe@rainbird.eu · www.rainbird.eu rbf@rainbird.eu · www.rainbird.fr
Rain Bird Australia Pty Ltd. Unit 13, Level1
85 Mt Derrimut Road PO Box 183
Deer Park, VIC 3023 Tel: 1800 724 624 info@.rainbird.com.au www.rainbird.com/au

Rain Bird International 1000 W. Sierra Madre Ave.
Azusa, CA 91702 USA
Tel: +1 626-963-9311
Rain Bird Deutschland GmbH Königstraße 10c 70173 Stuttgart DEUTSCHLAND
Tel: +49 (0) 711 222 54 158 rbd@rainbird.eu
Rain Bird Brasil Ltda. Rua Marques Póvoa, 215 Bairro Osvaldo Rezende
Uberlândia, MG, Brasil CEP 38.400-438
Tel: 55 (34) 3221-8210 www.rainbird.com.br

J “Rain Bird” and “Flo-Manager” are registered trademarks of Rain Bird Corp. I 2020 Rain Bird Corporation P/N: 690715-01 Rev. 12/20

Technical Support
Questions? Call Rain Bird toll free Technical Support at 1-866-544-1406 (USA and Canada only)
Find the full ESP-LXIVM user manual and trouble shooting information at www.rainbird.com