MEAN WELL - LOGO

300W Single Output with PFC Function
HSP-300 series

MEAN WELL HSP 300 Series 300W Single Output with PFC Function - QR

https://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdf

MEAN WELL HSP 300 Series 300W Single Output with PFC Function - COVER

MEAN WELL HSP 300 Series 300W Single Output with PFC Function - ICON 1

Features:

  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 seconds
  • Built-in active PFC function
  • Low leakage current<imA
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Low profile:31mm
  • Conformal coated
  • LED indicator for power on
  • Suitable for high efficiency moving sign applications
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL HSP-300-2.8 HSP-300-4.2 HSP-300.5
OUTPUT DC VOLTAGE 2.8V 4.2V 5V
RATED CURRENT 60A 60A 60A
CURRENT RANGE Note.5 0 – 60A 0 – 60A 0 – 60A
RATED POWER(convection) 168W 252W 300W
RIPPLE & NOISE (max.) Note.2 110mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 2.5-3V 3.6-4.4V 4.5-5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 2000ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.) 8ms/230VAC 8ms/115VAC at full load
INPUT VOLTAGE RANGE Note.4 180 – 264VAC 254 – 370VDC or 90-135VAC 127-190VDC
FREQUENCY RANGE 47 – 63Hz
POWER FACTOR (Typ.) PF:-0.93/230VAC PF .1.-0.98/115VAC at full load
EFFICIENCY (Typ.) 80% 85% 87%
AC CURRENT (Typ.) 2.8A/115VAC 1.4A/230VAC 3.9A/115VAC 1.95A/230VAC 4.7A/115VAC 2.35A/230VAC
INRUSH CURRENT (Typ.) Cold start 30A/115VAC 60A/230VAC
LEAKAGE CURRENT <1mA/ 240VAC
PROTECTION OVERLOAD 105-150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 3.22 – 3.78V 14.6 – 5.4V 15.7 – 7.0V
Protection type : Shut down olp voltage, re power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TEMP. -30 – +70-C (Refer to “Derating Curve)
WORKING HUMIDITY 20 -90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 – +85 C, 10 – 95% RH
TEMP. COEFFICIENT 10.03%/C (0 – 60 C )
VIBRATION 10 – 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC (Note 5)
SAFETY STANDARDS UL60950-1,IEC62368-1,GB 4943.1,EAC TP TC 004,TUV BS EN/EN 62368-1 approved
WITHSTAND VOLTAGE I/P-0/P:3.0KVAC I/P-FG:2.0KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-0/P, I/P-FG, 0/P-FG:100M Ohms/500VDC/25 C170%RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32),GB17625.1,GB/T 9254.1,Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN55035, light industry level (surge 4KV), EAC TP TC 020
OTHERS MTBF 1277.1K hrs min. Telcordia SR-332(Bellcore) ;148.2K hrs min. MIL-HDBK-217F (25°C)
DIMENSION 210’81’31mm (L’W’H)
PACKING 0.8kg; 15pcs/ 12.1kg/ 0.7CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Please refer to “Static Characteristics”.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on A450mm* 450mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.
For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

CASE NO.: 233B Unit:mm Tolerance:±1

MEAN WELL HSP 300 Series 300W Single Output with PFC Function - Mechanical Specification 1

AC Input Terminal(TB1) pin NO. Assignment

Pin No. Assignment Terminal
1 AC/L DG28C-B-03P-13-00AH
2 AC/N
3 Earth

DC Output Terminal pin NO. Assignment

Pin No. Assignment Terminal
1,2 +V NEL-400-02P
3,4 -V

Block Diagram

MEAN WELL HSP 300 Series 300W Single Output with PFC Function - Block Diagram 1

Derating Curve

MEAN WELL HSP 300 Series 300W Single Output with PFC Function - Derating Curve 1

Static Characteristics

MEAN WELL HSP 300 Series 300W Single Output with PFC Function - Derating Curve 2

Installation

  1. Operate with additional aluminum plate
    In order to meet the“Derating Curve”and the “Static Characteristics” ,HSP-300 series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and HSP-300 series must be firmly mounted at the center of the aluminum plate.
    MEAN WELL HSP 300 Series 300W Single Output with PFC Function - Installation 1
  2. For heat dissipation, at least 5cm installation distance around the PSU should be kept, shown as below:
    MEAN WELL HSP 300 Series 300W Single Output with PFC Function - Installation 2File Name:HSP-300-SPEC 2024-10-16

Downloaded from Arrow.com.

Documents / Resources

MEAN WELL HSP-300 Series 300W Single Output with PFC Function [pdf] Owner's Manual
HSP-300-2.8, HSP-300-4.2, HSP-300-5, HSP-300 Series 300W Single Output with PFC Function, HSP-300 Series, 300W Single Output with PFC Function, Single Output with PFC Function, PFC Function

References

Leave a comment

Your email address will not be published. Required fields are marked *