MEAN WELL EPP-300 series 300W Single Output with PFC Function User Manual
MEAN WELL EPP-300 series 300W Single Output with PFC Function

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 93%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in 12V/0.5A auxiliary output
  • 5″x3″ compact size
  • Free air convection for 200W and 300W with 20.5 CFM forced air
  • With power good and fail signal output
  • Built-in remote sense function
  • No load power consumption under 0.5W by PS-ON control
  • Standby 5V@1A with fan, @ 0.6A without fan
  • Operating altitude up to 5000 meters
  • 3 years warranty
    Symbols

SPECIFICATION

MODEL EPP-300-12 EPP-300-15 EPP-300-24 EPP-300-27 EPP-300-48
OUTPUT DC VOLTAGE 12V 15V 24V 27V 48V
RATED CURRENT (20.5CFM) 25A 20A 12.5A 11.12A 6.25A
CURRENT RANGE (convection) 0 ~ 16.67A 0 ~ 13.33A 0 ~ 8.33A 0 ~ 7.4A 0 ~ 4.17A
CURRENT RANGE (20.5CFM) 0 ~ 25A 0 ~ 20A 0 ~ 12.5A 0 ~ 11.12A 0 ~ 6.25A
RATED POWER (convection) 200W 200W 199.9W 199.8W 200.2W
RATED POWER (20.5CFM) 300W 300W 300W 300.24W 300W
RIPPLE & NOISE (max.)  Note.2 120mVp-p 120mVp-p 150mVp-p 200mVp-p 250mVp-p
VOLTAGE ADJ. RANGE Main output:11.4 ~ 12.6V Main output:14.25 ~ 15.75V Main output:22.8 ~ 25.2V Main output:25.65 ~ 28.35V Main output:45.6 ~ 50.4V
VOLTAGE TOLERANCE  Note.3 ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 2500ms, 30ms/230VAC 3000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 13ms/230VAC/115VAC at full load
INPUT VOLTAGE RANGE                  Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 90% 90% 92.5% 93% 93%
AC CURRENT (Typ.) 3.5A/115VAC 1.8A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/115VAC                     80A/230VAC
LEAKAGE CURRENT <2mA/240VAC
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 13.5 ~ 15V 16.2 ~ 18.5V 26 ~ 30V 29.5 ~ 33.5V 52 ~ 59.5V
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE 110℃±5℃ (TSW1) detect on heatsink of power transistor
115±5℃ (12V,15V),85±5℃ (24V,27V,48V) (TSW2) detect on heatsink of output diode
Protection type:  (TSW1)Shut down o/p voltage, recovers automatically after temperature goes down
Protection type: (TSW2)Shut down o/p voltage, re-power on to recover
FUNCTION 5V STANDBY 5VSB : 5V@0.6A without fan, 1A with fan 20.5CFM ; tolerance ± 2%, ripple : 150mVp-p(max.)
AUXILIARY POWER (AUX) 12V@0.5A for driving a fan ; tolerance -15% ~ +10%
PS-ON INPUT SIGNAL Power on: PS-ON = “Hi” or ” > 2 ~ 5V” ; Power off: PS-ON = “Low” or ” < 0 ~ 0.5V”
POWER GOOD / POWER FAIL 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value
ENVIRONMENT WORKING TEMP. -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃ , 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃ )
OPERATING ALTITUDE Note.7 5000 meters
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC      O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32),Conduction Class B,Radiation Class B;BS EN/EN61000-3-2,3;EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN60601-1-2, criteria A, EAC  TP  TC  020
OTHERS MTBF 160Khrs min. MIL-HDBK-217F (25℃ )
DIMENSION 127*76.2*35mm (L*W*H)
PACKING 0.37 Kg;   36pcs/14.3Kg/0.96CUFT;
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
  5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. Heat Sink HS1,HS2 can not be shorted.
  7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
    Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Product Dimension
Icon Grounding required: The grounding of the system level unit has to connect with Pin No.5 on CN1 of EPP-300 so as to pass EMI
Product Dimension

Warning Icon HS1,HS2 can not be shorted

Unit: mm
AC Input Connector (CN1): JST B5P-VH or equivalent

Pin No.

Assignment Mating Housing

Terminal

1

AC/N JST VHR or equivalent

JST SVH-21T-P1.1 or equivalent

24,

No Pin
3

AC/L

5

FG

DC Output Connector (CN2,CN3)

Pin No.

Assignment

Output Terminals

CN2 -V M3.5 Pan HD screw in 2 positions Torque to 8 lbs-in(90cNm)max.
CN3 +V

Function Connector(CN100):HRS DF11-4DP-2DS or equivalent

Pin No.

Status Mating Housing

Terminal

1 -S HRS DF11-4DS or equivalent HRS DF11 **SC or equivalent
2 +S
3 DC COM
4 PG

Function Connector(CN951): HRS DF11-4DP-2DS or equivalent

Pin No. Status Mating Housing

Terminal

1 5VSB HRS DF11-4DS or equivalent HRS DF1**SC or equivalent
2,4 DC COM
3 PS-ON

FAN Connector(CN952): JST S2B-XH or equivalent

Pin No.

Assignment Mating Housing

Terminal

1 DC COM JST XHP or equivalent JST SXH-001T-P0.6 or equivalent
2 +12V

Block Diagram

Block Diagram

PFC fosc: 65KHz
PWM fosc: 70KHz

Derating Curve
Derating Curve

Output Derating VS Input Voltage
Voltage Graph

Logo

Documents / Resources

MEAN WELL EPP-300 series 300W Single Output with PFC Function [pdf] User Manual
EPP-300 series, 300W Single Output with PFC Function, EPP-300 series 300W Single Output with PFC Function, Output with PFC Function, PFC Function, Function
MEAN WELL EPP-300 Series 300W Single Output With PFC Function [pdf] Owner's Manual
EPP-300 Series 300W Single Output With PFC Function, EPP-300 Series, 300W Single Output With PFC Function, Output With PFC Function, PFC Function, Function

References

Leave a comment

Your email address will not be published. Required fields are marked *