HASWILL ELECTRONICS STC-200 Temperature Controller User Guide
HASWILL ELECTRONICS STC-200 Temperature Controller

STC-200+ thermostat with just one relay to control the power supply status of the wired heater or cooler or output alarm.

Wiring Diagram

Wiring Diagram

Set the Aimed Temp Range

The aimed temperature range was defined from “SP” to “SP + F0”; hence you need to set both the “SP” and the “F0” value.

Function Menu

Code Function
F0 Temperature Hysteresis / Difference
F1 Protection Delay Time for the Compressor
F2 Lower Limit for SP Setting
F3 Upper Limit for SP Setting
F4 Refrigeration or Heating or Alarm Mode
F5 Calibration = Real. – Measured.

Set the “SP” value

  1. Press the Buttons key, shows the exists SP value;
  2. Press the Buttons or Buttons keys to change SP, which F2 and F3 limited;
  3. It will back to normal status from the setting interface in the 30s if without operation.

Set the “Hysteresis” Value?

  1. Hold the Buttons + Buttons keys simultaneously for 4s, and you will see the code F0.
  2. Next, press the  Buttons key again to see the current value and press the direction key to change it.
  3. At last, press the  Buttons  key to save the new data and back to the menu list.
  4. Hold the Buttons key for 3s to saves data and back to normal monitor status.
  5. Repeat steps 2,3,4 to change others.
  6. Hold the key Buttons for 3s to quit from setting or leave it alone; it will back to normal status in the 30s if without operation.

This is not a step-by-step user manual;
It just shows the key points.
The new user should read the Full-Content Version User Manual

QR Code

Haswill Electronics
STC-200+ Thermostat
Copyright Haswill-Haswell All Rights Reserved

Documents / Resources

HASWILL ELECTRONICS STC-200 Temperature Controller [pdf] User Guide
STC-200, Temperature Controller

References

Leave a comment