Socket User Manual
Updated December 28, 2020
The socket is a wireless indoor smart plug with a power-consumption meter for indoor use.
Designed as a European plug adapter (Schuko type F), the Socket controls the power supply of electrical appliances with a load of up to 2.5 kW. The socket indicates the load level and is protected from overload. Connecting to the Ajax security system via a secured Jeweller radio protocol, the device supports communication at a distance of up to 1,000 m in line of sight.
Socket operates with Ajax hubs only and does not support connecting via Oxbridge Plus cartridge or integration modules.
Use scenarios to program actions of automation devices (Relay, wall switch, or Socket) in response to an alarm, Button press, or a schedule. A scenario can be created remotely in the Ajax app.
How to create and cone a scenario in the Ajax security system
The Ajax security system can be connected to a central monitoring station of a security company.
Buy a smart plug Socket
Functional Elements
- Two-pin socket
- LED border
- QR Code
- Two-pin plug
Operating Principle
Socket switches on/off the 230 V power supply, opening one pole by the user command in the Ajax app or automatically according to a scenario, Button press, or a schedule.
The socket is protected against voltage overload (exceeding the range of 184–253 V) or overcurrent (exceeding 11 A). In case of overload, the power supply switches off, resuming automatically when voltage is restored to normal values. In case of overcurrent, the power supply switches off automatically, but can only be restored manually by the user command in the Ajax app.
The maximum resistive load is 2.5 kW. When using inductive or capacitive loads, the maximum switching current is reduced to 8 A at 230 V!
Socket with eversion 5.54.1.0 and higher can operate in pulse or bistable mode. In this e-version you can also select the relay contact status:
Normally closed — Socket stops supplying power when activated, and resumes when turned off.
Normally open — Socket supplies power when activated, and stops feeding when turned off.
Socket with e-version below 5.54.1.0 only works in bistability mode with a normally open contact.
How to e-version the device?
In the app, users can check the power or amount of energy consumed by electrical appliances connected via Socket.
At low loads (up to 25 W), current and power consumption indications may be displayed incorrectly due to hardware limitations.
Connecting
Before connecting the device
- Switch on the hub and check its Internet connection (the logo glows white or green).
- Install the Ajax app. Create the account, add the hub to the app, and create at least one room.
- Make sure that the hub is not armed, and does not update by checking its status in the Ajax app.
Only users with administrator rights can add a device to the app.
To pair the Socket with the hub
- Click Add device in the Ajax app.
- Name the device, scan it, or enter the QR code manually (located on the case and packaging), and select the room.
- Plug the Socket into a power outlet and wait 30 seconds — the LED frame will be green.
- Click Add — the countdown will begin.
- The socket will appear in the list of hub devices.
The device status update depends on the ping interval set in the hub settings. The default value is 36 seconds.
If the device failed to pair, wait 30 seconds and then retry.
For detection and pairing to occur, the device should be located in the coverage area of the hub’s wireless network (at the same object). A connection request is transmitted only at the moment of switching on the device.
When pairing the hub with the smart plug that was previously paired with another hub, make sure that it was unpaired with a former hub in the Ajax app. For correct unpairing, the device should be in the coverage area of the hub’s wireless network (at the same object): when unpaired correctly, the Socket LED frame continuously blinks green.
If the device has not been correctly unpaired, do the following to connect it to the new hub:
- Make sure that the Socket is outside the coverage area of the former hub’s wireless network (the indicator of the communication level between the device and the hub in the app is crossed out).
- Select the hub with which you want to pair Socket.
- Click Add Device.
- Name the device, scan or enter the QR code manually (located on the case and packaging), and select the room.
- Click Add — the countdown will begin.
- During the countdown, for a few seconds, give Socket at least 25 W load (by connecting and disconnecting a working kettle or lamp).
- The socket will appear in the list of hub devices.
The socket can be connected to one hub only.
States
- Devices
- Socket
Parameter | Value |
Jeweler Signal Strength | Signal strength between the hub and the Socket |
Connection | Connection status between the hub and the Socket |
Routed Through ReX | Displays the status of using the ReX range extender |
Active | State of the Socket (turned on/off) |
Voltage | The current input voltage level of the Socket |
Current | Current at the Socket input |
Current protection | Indicates whether the overcurrent protection is enabled |
Voltage protection | Indicates whether the overvoltage protection is enabled |
Power | Current consumption in W |
Electric Energy Consumed | The electric power consumed by the device is connected to the Socket. The counter is reset when the Socket loses the power |
Temporary Deactivation | Displays the status of the device: active or completely disabled by the user |
Firmware | Device e version |
Device ID | Device identi |
Settings
- Devices
- Socket
- Settings
Setting | Value |
First | The device name can be edited |
Room | Selecting the virtual room to which the device is assigned |
Mode | Selecting Socket operation mode: Pulse — when activated, Socket generates a pulse of a given duration Bistable — Socket, when activated, changes the state of contacts to the opposite Settings are available with firmware version 5.54.1.0 and higher |
Contact status | Normal contact state • Normally closed • Normally open |
Pulse duration | Selecting the pulse duration in the pulse mode: From 0.5 to 255 seconds |
Overcurrent Protection | If enabled, the power supply switches off if the current load exceeds 11A, if disabled the threshold is 6A (or 13A for 5 seconds) |
Overvoltage protection | If enabled, the power supply switches off in case of a voltage surge beyond the range of 184 – 253 V |
Indication | The option of disabling the LED frame of the device |
LED Brightness | The option of adjusting the brightness of the LED frame of the device (high or low) |
Scenarios | Opens the menu for creating and con Learn more |
Jeweller Signal Strength Test | Switches the device to the signal strength test mode |
User Guide | Opens the Socket User Guide |
Temporary Deactivation | Allows the user to deactivate the device without removing it from the system. The device will not execute system commands and participate in automation scenarios. All notices will be ignored Please note that the deactivated device will save its current state (active or inactive) |
Unpair Device | Disconnects the device from the hub and deletes its settings |
Indication
The socket informs the user of the power level consumed by connected appliances using the LED.
If the load is more than 3 kW (purple), the current protection activates.
Load level | Indication |
No power on the Socket | Don’t have any indication |
Socket turned off | Blue |
The socket turned on, but no load | Green |
~550 W | Yellow |
~1250 W | Orange |
~2000 W | Red |
~2500 W | Dark red |
~3000 W | Purple |
One or more types of protection triggered | Smoothly lights up and goes out red |
Hardware failure | Quick red |
The exact power can be seen in the Ajax Security System application
Functionality Testing
The Ajax security system allows conducting tests for checking the functionality of connected devices.
The tests do not start immediately but within a period of 36 seconds when using default settings. The test time starts depending on the settings of the detector ping interval (the “Jeweller” menu in the hub settings).
Jeweler Signal Strength Test
Installation of the Device
The location of the Socket depends on its remoteness from the hub, and obstacles hindering the radio signal transmission: walls, and large objects inside the room.
Do not install the device near sources of magnetic ed objects, wireless chargers, etc.) and inside rooms with temperature and humidity outside the permissible limits!
Check the Jeweller signal level at the installation location. If the signal level is low (one bar), we cannot guarantee the stable operation of the device.
If the device has a low or unstable signal strength, use a ReX radio signal range extender.
The socket is designed to connect to a European two-pin socket (Schuko type F).
Maintenance
The device does not require maintenance.
Tech specs
Actuating element | Electromagnetic relay |
Service life | At least 200,000 switches |
Voltage and type of external power supply | 110–230 V, 50/60 Hz |
Voltage protection for 230 V mains | Yes, 184–253 V |
Maximum load current | 11 A (continuous), 13A (up to 5 s) |
Operating modes | • Pulse and bistable (e-version is 5.54.1.0 or higher. Manufacture date from March 4, 2020) • Only bistable (e-version is lower than 5.54.1.0) |
Pulse duration | 0.5 to 255 seconds (e-version is 5.54.1.0 or higher) |
Maximum current protection | Yes, 11 A if the protection is turned on, up to 13 A if the protection is turned off |
Maximum temperature protection | Yes, +85°С. The socket turns off automatically if the temperature is exceeded |
Electric shock protection class | Class I (with grounding terminal) |
Energy consumption parameter check | Yes (current, voltage, power consumption) |
Load indicator | Yes |
Output power (resistive load at 230 V) | Up to 2.5 kW |
Average energy consumption of the device on standby | Less than 1 W⋅h |
Frequency band | 868.0 – 868.6 MHz |
Compatibility | Operates with all Ajax hubs, and range extenders |
Maximum radio signal power | 8,97 mW (limit 25 mW) |
Radio signal modulation | GFSK |
Radio signal range | Up to 1000 m (when there are no obstacles) |
Installation method | In power outlet |
Operating temperature range | From 0°С to +40°С |
Operating humidity | up to 75% |
Protection class | IP20 |
Overall dimensions | 65.5 × 45 × 45 mm (with plug) |
Weight | 58 g |
In the case of using inductive or capacitance load, the maximum switched current is reduced to 8 A at 230 V AC!
Complete Set
- Socket
- Quick Start Guide
Warranty
Warranty for the “AJAX SYSTEMS MANUFACTURING” LIMITED LIABILITY COMPANY products is valid for 2 years after the purchase.
If the device does not work correctly, you should t service—in half of the cases, technical issues can be solved remotely!
The full text of the warranty
User Agreement
Customer support: support@ajax.systems
Documents / Resources
![]() |
AJAX type F Socket [pdf] User Manual type F, Socket, type F Socket |