xpr MTPX-OSDP-EH CSN Reader with OSDP Interface Instruction Manual
Reader with OSDP Interface

SPECIFICATIONS

Technology: Proximity (125 KHz)
Interface: RS-485, OSDP compatible
Supported credentials: EM4100, HID Compatible
Read range: Up to 6 cm
Power supply: 9 – 14 VDC, 110mA
Sound Indicator: Internal buzzer
LED Indicators: Red, Green and Orange (Red + Green)
Environmental rating: Outdoor, IP65
Operating humidity: 5% – 95% relative humidity, non-condensing
Operating temperature: -20°C to 50°C
Mounting: Surface mount
Panel connection: Cable 0.5 m
Dimensions (mm): 92 x 51 x 27

MOUNTING

  1. Dimension
  2. 3 (3 x 30mm)
    Dimension
  3. 1 (M3 x 6mm)
    Dimension
  4. Plug

Rubber gasket

Front
Front
Back
Back

Mounting base (optional
Mounting Base

WIRING

RS-485 bus termination

120 ohm OFF
2-OFF
Switch Off
120 ohm ON
2-ON
Switch On

Ferrite Core
Wiring Connection
Wrap the wires around the ferrite core (1 turn). The ferrite core is provided with the kit and it is used to reduce the EMI
Connection reader to OSDP controller
Reader Connection
Recommended cabling:
Multiconductor cable 2 twisted pair with shielding .Max length: up to 1200m.The cable shielding will be connected to the fixing clamp of the access unit.

PROGRAMING AND SETTINGS

Procedure for SCBK (Secure key for OSDP communication) Reset: Power the reader. Set DIP Switch 1 to ON and in the less than 5 sec set it back to OFF position.
Switch On

VISUAL AND AUDIO SIGNALIZATION

All signalization is managed by the OSDP controller except: Reader OFF Line: Red blinking LED.

SOFTWARE SETTINGS

XPR Toolbox is software for settings and firmware update of the reader. Reader is ready to be used “out of the box”, so is not required to be configured by the software. XPR Toolbox can be downloaded from https://software.xprgroup.com/

CONNECTION TO PC

Connection

To setup the reader or update the firmware, run the XPR Toolbox and select ”OSDP Standard readers” and ”MTPX-OSDP-EH” and click on “Open” tab. Follow the instruction in the software to set up or update firmware.

Ce Mark   This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU

Xpr Logo

Documents / Resources

xpr MTPX-OSDP-EH CSN Reader with OSDP Interface [pdf] Instruction Manual
MTPXS-OSDP-EH, MTPXBK-OSDP-EH, MTPX-OSDP-EH CSN Reader with OSDP Interface, CSN Reader with OSDP Interface, Reader with OSDP Interface, OSDP Interface, Interface

References

Leave a comment