Spanet-LOGO

Spanet SV-4T Support Hub Controller

Spanet-SV-4T-Support-Hub-Controller-PRODUCT

OVERVIEW

DISPLAY MODE ICONS

  • Spanet-SV-4T-Support-Hub-Controller-FIG-1Water Temperature
  • Spanet-SV-4T-Support-Hub-Controller-FIG-2Set Temperature
  • Spanet-SV-4T-Support-Hub-Controller-FIG-3Clock

MENU ICONS

  • Spanet-SV-4T-Support-Hub-Controller-FIG-4Sleep timer menu icon
  • Spanet-SV-4T-Support-Hub-Controller-FIG-5Light menu icon
  • Spanet-SV-4T-Support-Hub-Controller-FIG-6Blower menu icon

STATUS ICONS

  • Spanet-SV-4T-Support-Hub-Controller-FIG-7Keypad locked
  • Spanet-SV-4T-Support-Hub-Controller-FIG-8Sanitise cycle operating
  • Spanet-SV-4T-Support-Hub-Controller-FIG-9Filtration cycle operating
  • Spanet-SV-4T-Support-Hub-Controller-FIG-10Fault conditions have occured

Spanet-SV-4T-Support-Hub-Controller-FIG-11

USING INSTRUCTION

CHANGING LIGHT MODES
When the light is first turned on the display will show the current light mode in use. Press ( or button to step through the choice of light modes:

  • WHTE
    • White Light
  • UCLR
    • User Colour
  • FADE
    • Fade Effect
  • STEP
    • Step Effect
  • PARTY
    • Party Effect

CHANGING LIGHT SPEED OR LIGHT COLOUR

Depending on the light mode selected the Light (spd/cir) Spanet-SV-4T-Support-Hub-Controller-FIG-13 button will activate one of three light mode option screens.

  • CL: XX
    • User Colour Number
  • L.SPD
    • Light Transition Speed
  • L.BRT
    • Light Brightness
  • Press Spanet-SV-4T-Support-Hub-Controller-FIG-12the button to adjust each setting.
  • Press OK button to save each setting and move to the next setting.

Note: All light settings are saved for future ON / OFF use.

FULL KEYLOCK
Press and hold this button combination until LOCK appears on the display:Spanet-SV-4T-Support-Hub-Controller-FIG-15

Repeat the button combination to unlock.

Note: Once locked if any button is pressed the keystroke will be ignored and the display will show LOCK.

PARTIAL KEYLOCK
Press and hold this button combination until LOCK appears on the display:Spanet-SV-4T-Support-Hub-Controller-FIG-15

Repeat the button combination to unlock.

Note: Once locked only pumps, blower, light, and sanitise buttons can be used. Access to all other buttons is disabled.

SETUP MENU

  • The setup menu allows customization of the adjustable controller settings. Menu access and item adjustments are carried out as follows:
  • Press and holdSpanet-SV-4T-Support-Hub-Controller-FIG-12 buttons together until [MODE] is displayed.
  • Press Spanet-SV-4T-Support-Hub-Controller-FIG-12to navigate through setup menu items.
  • Press OK to enter item adjustment.
  • Press Spanet-SV-4T-Support-Hub-Controller-FIG-12on to adjust the setting.
  • Press OK to confirm the setting and exit.

All setup menu items follow the same adjustment procedure. Menu items that can be adjusted are as follows:

[MODE] OPERATING MODES
Operating modes affect heating and filtration behavior. The choices are:

  • NORM Normal heating & filtration
  • AWAY Heating disabled. Filtration reduced to 1hr p/day.
  • WEEK Mon-Thu (works like AWAY mode) Fri-Sun (works like NORM mode)

[FILT] DAILY FILTRATION TIME
Adjust the hours of filtration per day. Filtration limits differ for the type of pump:

  • Circ Pump (2A or less) 1-24 hrs
  • Jet Pump (2spd or 1spd) 1-8 hrs

[F.CYC] FILTRATION CYCLES
This setting defines how often filtration cycles occur. Filtration can be set to run every 1/2/3/4/6/8/12 or 24 hrs

[SNZE] SLEEP TIMERS
Used to disable automatic heating and filtration during certain times of day or night. Upon entering the SNZE menu there are four choices:

  1. SNZ
    • Sleep Timer #1
  2. SNZ
    • Sleep Timer #2
  3. R. SET
    • Reset timers to default
  4. EXIT
    • Exit the sleep timer menu

Only one sleep timer needs to be set however two timers are provided to facilitate different sleep settings on different days. Each sleep timer setting consists of a weekday setting, start time, and stop time (refer to below).

  • x. DAY Day(s) of operation
  • x.BGN Sleep timer begins time
  • X.END Sleep timer end time

Use the Up, Down & OK buttons to adjust and confirm each setting.

[P.SAV] POWER SAVE (off-peak)
Reduce operating costs by limiting filtration and heating to occur during cheaper off-peak power periods. There are three P.SAV modes:

  • OFF P.SAV disabled
  • LOW Off-peak filtration only
  • HIGH Off-peak filtration & heating

Once P.SAV mode is selected the begin and end times of the PEAK power tariffs must be set so the control knows NOT to operate during those peak hours.

  • BGN Peak power begins time
  • END Peak power end time

[W.CLN] AUTOMATIC SANITISE
Adjust the start time of the 10-minute automatic daily sanitizing cycle. The setting can be adjusted from 0:00 to 23:59.

[D.DIS] DEFAULT DISPLAY MODE
Used to adjust the default display mode shown on the keypad. Setting choices:

  • W.TMP Water Temperature
  • S.TMP Set Temperature
  • TIME Clock

[T.OUT] LOAD TIME OUTS
All accessory loads (pumps & blowers) automatically turn off after a time-out period has elapsed. Adjust the time-out period from 10-60 minutes.

[H.PMP] HEAT PUMP MODE
Defines heat pump operating mode:

  • AUTO Heat & Cool
  • HEAT Heat Only
  • COOL Cool Only
  • OFF Heat Pump Disabled

[H.ELE] ELEMENT BOOST
Enables/disables SV electric element to boost heat pump heating if the water temperature is 2°C or more below set temperature point OR the heat pump has been operating for more than 1hr.

  • OFF Element disabled (heat pump only)
  • ON SV element + heat pump