Pepperl Fuchs VIM62PP Vibration Sensor
Product Information
- Product Name: Vibration sensor VIM62PP-E1V16-0PE-I420V15
- Extended temperature range
- Screw-in thread for simple installation
- Simple electrical commissioning
- Rugged stainless steel housing
- Vibration velocity in mm/s via root mean square formation (rms)
- Suitable for use in hazardous area up to Zone 1/21 with type of protection intrinsic safety
- Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection intrinsic safety
Product Usage Instructions
To use the Vibration sensor VIM62PP-E1V16-0PE-I420V15, follow the instructions below:
- Make sure the ambient temperature is within the permissible range.
- Install the sensor by screwing it in using the provided thread.
- Connect the sensor to a power source with an operating voltage between 10 and 30 V DC.
- Ensure the maximum current consumption does not exceed 25 mA.
- Connect the output of the sensor to the desired device using a connector.
- For use in hazardous areas, follow the specified connection instructions and ensure compliance with the applicable approvals and certificates.
- To measure vibration velocity, set the measuring range to 0-16 mm/s.
- Monitor the vibration velocity output through the analog current output ranging from 4 to 20 mA.
- Take into account the measurement accuracy and cross-sensitivity of the sensor.
- Ensure the sensor is properly protected against shocks and vibrations according to the specified standards.
For further information and support, refer to the product manual or contact Pepperl+Fuchs Group.
Vibration sensor
VIM62PP-E1V16-0PE-I420V15
- Extended temperature range
- Screw-in thread for simple installation
- Simple electrical commissioning
- Rugged stainless steel housing
- Vibration velocity in mm/s via root mean square formation (rms) < Suitable for use in harzadous area up to Zone 1/21 with type of protection intrinsic safety
Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection intrinsic safety
Function
The vibration sensor determines the vibration quantity using rms (root meas square) averaging. This form of quadratic averaging or pre-filtering enables precise trend statements about the condition of the application.
The sensor’s design is impressively robust against tough environmental conditions.
The stainless steel housing provides optimal protection against corrosion. The wide temperature range of the sensor enables reliable measured values even in harsh conditions.
The simple mounting allows for commissioning in any application.
Dimensions
Technical Data
General specifications | ||
Type | Vibration sensor | |
Measuring technology | MEMS |
Series | Performance Plus Line | |
Measured variable | Vibration velocity | |
Measurement range | ||
Vibration velocity | v- rms | 0 … 16 mm/s |
Measurement accuracy | ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz)
Complies with the tolerance requirements of DIN ISO 2954 for measurement range greater than 8 mm/s |
|
Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis | |
Frequency range | 10 … 1000 Hz | |
Averaging time | for v-rms: 2 s | |
Electrical specifications | ||
Fusing | external fuse is required: 3 A , semi-time-lag , 30 V DC | |
Operating voltage | UB | 10 … 30 V DC |
Current consumption | max. 25 mA | |
Power consumption | P0 | max. 750 mW |
Time delay before availability | tv | 10 s (rms filter is calculated intially with measurement data before they are available at the output) |
Surge protection | up to 2 kV | |
Output 1 | ||
Output type | analog output, current
output of the vibration variable |
|
Output rated operating current | 4 … 20 mA | |
Load resistor | ≤ 500 Ω | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66, IP67 | |
Shock resistance | DIN EN 60068-2-27, 60 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 … 1000 Hz | |
Approvals and certificates | ||
IECEx approval | ||
Equipment protection level Gb | IECEx CSAE 22.0042X | |
Equipment protection level Db | IECEx CSAE 22.0042X | |
ATEX approval | ||
Equipment protection level Gb | CSANe 21 ATEX 1074 X | |
Equipment protection level Db | CSANe 21 ATEX 1074 X | |
UL approval | ||
Ordinary Location | E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request |
|
Maximum permissible ambient temperature | max. 60 °C (max. 140 °F) | |
Ambient conditions | ||
Ambient temperature | -40 … 60 °C (-40 … 140 °F) | |
Measuring head temperature | -40 … 125 °C (-40 … 257 °F) directly at the mounting point | |
Storage temperature | -40 … 60 °C (-40 … 140 °F) | |
Mechanical specifications | ||
Connection type | plug | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Housing length | 82.35 mm | |
Housing diameter | 31 mm | |
Degree of protection | IP66 / IP67 only in connected state | |
Connector | ||
Threading | M12 | |
Number of pins | 5 | |
Mass | approx. 200 g | |
General information |
- Use in the hazardous area
see instruction manuals Only use accessories specified by the manufacturer.
Connection
Connection Assignment
Installation
Further Documentation
The sensor manual is also available as detailed overall documentation. Among other things, installation, grounding concepts and mounting are described there in detail.
You can access the manual via the product detail page at www.pepperl-fuchs.com.
Note
The correct electrical connection and the selection of the appropriate grounding concept are crucial for malfunction-free operation of the sensor. For detailed information you may refer to the manual of the sensor.
Accessories
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs Group www.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Germany: +49 621 776 1111 fa-info@de.pepperl-fuchs.com
Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com
Documents / Resources
![]() |