MHOxygen IPR-2D EDS 4ip For RV-10 With IPR Built in Oxygen System

MHOxygen-IPR-2D-EDS-4ip-For-RV-10-With-IPR-Built-in-Oxygen-System-PRODUCT

Specifications

  • Model: IPR-2D
  • Dimensions: Inches

Product Usage Instructions

  • Installation
    • Refer to the EDS 2IP-4IP manual for detailed operation and installation specifications.
    • Refer to the EDS 2IP-4IP for wiring schematics.
    • Ensure proper connection of the main O2 out and emergency O2 out.
    • In the high-pressure interface section, all four SAE-4 fitting locations are interchangeable.
    • Connect the customer interface cable to the designated port. Do not interface directly with the DE-09 port on the IPR body.
  • Operation
    • Follow the manufacturer’s guidelines for operating the product effectively. Ensure all connections are secure and functional before use.
  • Maintenance
    • Regularly inspect the product for any signs of wear and tear. Clean as necessary and replace any damaged components promptly.

FAQs

  • Can I cover the filter port?
    • No, do not cover the filter port as it may affect the performance of the product.
  • Are the SAE-8 threads compatible with SAE-4 ports?
    • The SAE-8 threads with SAE-4 ports are designed for internal use only and should be considered based on the specific application requirements.
  • How should I connect the customer interface cable?
    • Connect the customer interface cable to the designated port on the product. Do not interface directly with the DE-09 port on the IPR body.

“`

1

2

3

4

REVISION HISTORY

NOTES: – ALL DIMENSIONS ARE IN INCHES.

REV

ECO NO. YYYY-MM-D

NAME

NOT ES

2024D-046 2024-08-14

KQM Initial Release

– SEE EDS 2IP-4IP MANUAL FOR

A

DETAILED OPERATION AND INSTALLATION SPECIFICATIONS.

A

– SEE EDS 2IP-4IP FOR WIRING

SCHEMATICS

CUSTOMER INTERFACE

MAIN O2 OUT

EMERGENCY O2 OUT

– IN HIGH-PRESSURE INTERFACE SECTION, ALL FOUR SAE-4 FITTING LOCATIONS ARE INTERCHANGEABLE. STOCK CONFIGURATION IS SHOWN

CABLE. CONNECT TO THIS CABLE CUSTOMER END ONLY, DO NOT INTERFACE DIRECTLY WITH THE DE-09

4.640

ON THE IPR BODY

4.445

3.583

FILTERED AMBIENT

3.000

2.939

.620

PORT, DO NOT COVER

2.350

B

B

LOW-PRESSURE RELIEF DEVICE

1.863 2.763 3.563
1.163

C

HIGH-PRESSURE INTERFACE SECTION,

(4) SAE-4 PORTS

D 1

.861

HIGH PRESSURE RELIEF DEVICE PRESSURE SENDING UNIT. ALLOW EXTRA SPACE ON THIS SIDE TO MAKE ROOM FOR CUSTOMER INTERFACE CABLE 1.750
TANK DIP-TUBE, NOT USED IN REMOTEMOUNT APPLICATIONS
2

VARIES

SAE-8 THREADS W/ SAE-4 PORT (INTERNAL)

REMOTE MOUNT NUT,

ONLY USED IN REMOTEMOUNT APPLICATIONS

C

REMOTE MOUNT INTERFACE FITTING OF CHOICE (JIC-4 SHOWN)

UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN INCHES. DIMENSIONS IN [ ] ARE MILLIMETERS (REF) TOLERANCES ARE: 0.X ±0.015 ANGLES ± 3° 0.XX ±0.010 FRACTIONS ± 1/64 0.XXX ±0.005
63 INTERPRET GD&T PER ASME 14.5

MH MOUNTAIN HIGH E&S CO. REDMOND, OR. USA
THIS DOCUMENT AND ALL TECHNICAL DATA HEREON DISCLOSED ARE PROPERTY OF MOUNTAIN HIGH E&S CO. AND SHALL NOT BE USED, RELEASED OR DISCLOSED IN WHOLE OR PART WITHOUT WRITTEN PERMISSION FROM MOUNTAIN HIGH E&S CO. THIS DOCUMENT
MUST BE RETURNED TO MOUNTAIN HIGH E&S CO. IMMEDIATELY UPON REQUEST.

THIRD ANGLE DRAWN

DOC. KQM TITLE

IPR-2D Form Factor Detail

D

PROJECTION

2024-08-14

CHECKED

EAM DOC.

2024-08-21 NUMBER

5IPR2-080-000

– DWG
REV.

ENGINEER

JB SRC

2024-08-21 FILE

AIPR2-110-000$A1

INV. PART NUMBER

MODEL #:

IPR-2D

DO NOT SCALE APPROVED

HBS DWG FORMAT:

DWG

DRAWING

2024-08-21 ESR-002 Rev H [27] SCALE

1:2

DWG SHEET

1

OF 1

DWG A
SIZE 11×8½

3

4

IP System Description

Congratulations on choosing the Mountain High EDS ip system, the international standard for aviation oxygen systems. The ip stands for intelligent peripheral, meaning each oxygen outlet station has a micro-computer that constantly monitors respiratory aspects of each person. Through the cannula or face mask, the ip system characterizes the physiological respiratory profile to adapt to individual needs and situational awareness. In addition, the ip system gleans a good approximation of a persons PaO2 saturation (amount of O2 carrying blood cells that are able to carry O2 to the body) ensuring that the proper amount of oxygen is delivered at various altitudes. The ip system is a completely integrated, adaptive, intelligent aviation oxygen system. No other aviation oxygen system can provide such conservation of your oxygen with unmatched safety and comfort.

MHOxygen-IPR-2D-EDS-4ip-For-RV-10-With-IPR-Built-in-Oxygen-System-FIG- (1) MHOxygen-IPR-2D-EDS-4ip-For-RV-10-With-IPR-Built-in-Oxygen-System-FIG- (2)

Basic ip system configuration

The EDS ip (Electronic oxygen Delivery System, intelligent peripheral) has four (4) main parts:

1) The ip System Control & Display Head
2) Oxygen outlets / Distributor Stations
3) The oxygen source (Tank / Cylinder) & IPR regulator.
4) Emergency bypass control switch

MHOxygen-IPR-2D-EDS-4ip-For-RV-10-With-IPR-Built-in-Oxygen-System-FIG- (3)

The EDS-2ip is a two-place system engineered to fit into the standard area for a 2.25″ instrumet hole.
The EDS-4ip is a four-place system engineered to fit into a 2.25″ wide by 3.125″ tall instrument hole.
Both of these lighted control heads can be configured to fit into almost any aircraft installation including an overhead console requiring only ~1.75″ of depth.

LCD Icons, Functions & Meanings

2ip LCD

MHOxygen-IPR-2D-EDS-4ip-For-RV-10-With-IPR-Built-in-Oxygen-System-FIG- (4)

Station Status Circle
Everything unique to the stations will show up in these circles
Station O2 Flow-flags
Shows station has responded with a pulse of oxygen
Station Active inspiration response
This icon alone will show every time a valid inspiration effort has been detected or the red button has been pressed on that station
DIST unit.
Station Alert icon
Shows for Apnea, flow-faults, missing stations
O2 Alert Icon
Shows during situations where oxygen may not be properly delivered or where O2 supply may be an issue.
Dual purpose Icon
While system is ON this icon shows that the system is operating in ‘Class-A’ mode, a PA at and above 17.5 K ft. While system is OFF this icon shows that the Auto-On feature is armed to turn the system on at ~10 K ft.
This icon flashes if the system has been turned off after it came on by the Auto-on feature. Once you decend below a PA of ~10 K ft. it will stop flashing to indicate that the Auto-on feature is still active and armed.
NIGHT (now / normal) mode
System will respond with O2 at all pressure altitudes regardless of any preset D mode trip points. Pages 3, 8 & 9
DAY (delayed) mode
System will delay response of O2 until the pressure altitude is at or above the preset D-mode trip-points. Pages 3, 8 & 9
Analog display
compliments digital readout with cylinder pressure, pressure altitude and regulator pressure if the optional pressure sending kit is installed.
Display Mode
Compliments analog & digital display
a) PA X1000 Pressure Altitude: 0 – 31,500 ft.
b) PSI X100 Cylinder pressure: 0 – 3,150 psig.
c) PSI (optional) Regulator pressure: 0 – 31.5 psig.
Digital ReadOut
Compliments analog display with a numerical data. The small right hand digit represents different scales per display mode.
a) Hundreds (100) of ft. while in PA.
b) Tens (10) of psig. while in Tank / Cylinder pressure.
c) Tenths (1/10) while in regulator pressure readout.
Time / clock icon
Shows a time constrained condition such as low O2 supply alerts.
NOTE: All these icons will have different meanings during times while you are in the system or station set-up modes.

4ip LCD

MHOxygen-IPR-2D-EDS-4ip-For-RV-10-With-IPR-Built-in-Oxygen-System-FIG- (5)

Customizing System Settings

Settings for the control head can be customized for each installation or desired effect. They are: LCD contrast, LCD back light balance with aircraft lighting, key-pad back light balance and audio volume. While you are in any of these setting modes the system will continue to operate responding to users and delivering oxygen normally. However, if at any time a critical error occurs while you are in any of the setting modes, you will be immediately kicked out of the settings mode and sent back to normal operating mode so that the error can be interpreted and the correct action can be taken.

KeyPad Function Guide

To enter the settings mode, only accessible while the system is on, press and hold the SEL button and then press the CLR/O or MODE button. To leave any of the setting modes simply press and hold the SEL key for about three seconds. The unit  will store any changes you have made and resume displaying your operational situation. If the control head does not detect anykey button actions for 15 seconds it will revert back to the normal operating mode and save any changes you have made.

MHOxygen-IPR-2D-EDS-4ip-For-RV-10-With-IPR-Built-in-Oxygen-System-FIG- (6)

Documents / Resources

MHOxygen IPR-2D EDS 4ip For RV-10 With IPR Built in Oxygen System [pdf] Owner's Manual
IPR-2D, IPR-2D EDS 4ip For RV-10 With IPR Built in Oxygen System, IPR-2D, EDS 4ip For RV-10 With IPR Built in Oxygen System, RV-10 With IPR Built in Oxygen System, Built in Oxygen System, Oxygen System, System