eufy A1 Smart Scale A1 with Bluetooth

eufy A1 Smart Scale A1 with Bluetooth

What’s in the Box

  • Smart Scale
    What’s in the Box
  • AAA Battery (×3)
    What’s in the Box
  • Owner’s Manual
    What’s in the Box

Inserting the Batteries

  1. Turn the scale over and place it on a flat surface.
  2. Open the battery door and insert three AAA batteries. Make sure the positive and negative ends are facing the correct polarity directions marked in the battery compartment.
    • The digits “ ” will show on the LED display.
  3. Close the battery door and wait until the digits “ ” are shown on the LED display.
    What’s in the Box

Symbol Icon will appear on the LED display when the batteries are low. Replace all three batteries at the same time. Do not mix new and used batteries.

Installing the EufyLife App and Pairing

  1. Download the EufyLife app from the App Store (iOS devices) or Google Play (Android devices), or by scanning the QR code.
  2. Enable Bluetooth on your smartphone.
  3. Open the EufyLife app and follow the on-screen instructions to pair the scale with your device.
    Once paired, the app and scale will automatically connect the next time the app is opened.
    QR Code Installing the EufyLife App and Pairing
Symbol Status Icon Indicates
Flashing Pairing
Solid Connected
  • Symbol This scale is compatible with devices running iOS 11.0 and above or Android 6.0 and above.
  • Do not pair the scale from your smartphone’s Bluetooth menu. Use the EufyLife app to pair the scale with your smartphone

Starting a Measurement

Before taking your first measurement, you will need to create and set up a user ID in the EufyLife app.

  1. Place the scale on a hard and flat surface..
  2. Open the EufyLife app and select Smart Scale on the device homepage.
  3. Step barefoot onto the scale. An analysis of your body’s composition will begin automatically.
  • Symbol Step on the center of the scale barefoot. Stand still and keep full contact with the electrodes until the measurement is complete.
    Starting a Measurement

For body weight measurement:

Place the scale on a hard and flat surface.

Starting a Measurement

For body composition analysis:

Stand still and uniformly touch the electrodes with bare and dry feet. .

Starting a Measurement

Weight-Only Measurement

This scale can also be used as a conventional weight-reading scale. You can simply step on the scale to measure your current weight without opening the EufyLife app.

Maintenance

Regularly clean the scale with a dry or slightly dampened soft cloth.

Maintenance

  • Symbol Do not wash the scale with water or immerse it in water.
  • Never use detergents to clean the scale as this may cause it to malfunction or discolor.

Troubleshooting

Error Messag:

Symbol Overload. The device will power off. Stop using this scale for measurement
Symbol Low battery. The device will power off. Replace all three batteries at the same time.
Symbol Measurement failure.
  • Step barefoot and keep full contact with the electrodes.
  • Stand still until the measurement on the LED display locks.

When Measuring

Issue Cause Solution
Abnormal measurement results:

 

  • Incorrect posture
  • Step onto the scale barefoot and stand still.
  • Device is placed on soft carpeting or uneven surface.
  • Place the device on a hard and flat surface.
LED display does not turn on after stepping onto the scale.
  • Batteries not installed.
  • Install three new batteries
  • Worn batteries.
  • Replace all three batteries at the same time.
Scale does not proceed to analyse body composition.
  • Taking a measurement while wearing shoes or socks.
  • Stand barefoot on the scale and keep feet in full contact with the electrodes when taking a measurement.

Specifications

Product Model T9120
Power Source 4.5 V (3 × AAA batteries)
Measurement Units Kilogram
Unit Increments 5–75 kg 0.1 kg | 75-150 kg 0.2 kg
Body Fat Unit Increments 0.1 %
Body Water Unit Increments 0.1 %
Muscle Mass Unit Increments 0.1 %
Measurement Range 5-150 kg
Working Environment Temperature: 5 – 40 °C Humidity: 20 – 90% RH
Storage Environment Temperature: -20 – 50 °C Humidity: <= 90% RH
Operating Frequency Range 2402 MHz – 2480 MHz
Radio-Frequency Power -3.07 dBm
Dimension 260 × 260 × 23 mm
Net Weight 1.1 kg

Customer Service

 Contact Us
Lifetime technical support
Symbol support.mea@eufy.com (For Middle East and Africa Only)
support@eufy.com (Global)
Symbol www.eufy.com
Symbol WhatsApp Chat: +971 529750842
(UAE) +971 8000320817
(KSA) +966 8008500030
(Kuwait) +965 22069086
(Egypt) +20 8000000826
(MENA) +971 529750842
For more support phone numbers, please visit: https://support.eufy.com/s/phonecontactus Hereby, Anker Innovations Limited declares that this device is in compliance with The Product Security and Telecommunications Infrastructure (Security Requirements for Relevant Connectable Products) Regulations 2023. For the Statement of Compliance, visit the website: https://www.eufy.com/uk/pstirelated.

Documents / Resources

eufy A1 Smart Scale A1 with Bluetooth [pdf] Instruction Manual
A1 Smart Scale A1 with Bluetooth, A1, Smart Scale A1 with Bluetooth, Scale A1 with Bluetooth, Bluetooth

References

Leave a comment

Your email address will not be published. Required fields are marked *