R17V2

EPH CONTROLS R17-V2 1 Zone Time Switch

1 Zone Timeswitch

Installation and Operating Guide

EPH CONTROLS logo1

EPH CONTROLS R17-V2 1 Zone Time Switch

1 Zone Timeswitch

Installation Instructions

EPH CONTROLS - Bullet 2 Factory Default Settings EPH CONTROLS R17V2 1 Zone Timeswitch - a1

Contacts:                     Volt Free Contacts
Program:                     5/2D
Backlight:                    On
Keypad Lock:              Off
Frost Protection:         Off
Operating Mode:         Auto
Pin Lock:                     Off
Service Interval:           Off
Zone Title:                   ZONE

EPH CONTROLS - Bullet 2 Specifications

Power Supply:               230VAC
Ambient Temperature:  0 … 50˚C
Dimensions:                  161 x 100 x 31 mm
Contact Rating:              3(1)A
Program Memory          5 Years
Temperature Sensor:      NTC 100K
Backlight:                       White
IP Rating:                       IP20
Battery:                          3VDC Lithium LIR2032 & CR2032
Backplate:                       British System Standard
Pollution degree:            2 (Resistance to voltage surge 2000V; as per EN60730)
Software Class:               Class A

EPH CONTROLS - Bullet 2 LCD Display

[1]  Displays current time.
[2]  Displays current day of the week.
[3]  Displays zone title.
[4]  Displays current mode.
[5]  Displays when keypad is locked.
[6]  Displays when frost protection is activated.
[7]  Displays current date.

EPH CONTROLS R17V2 1 Zone Timeswitch - a2

EPH CONTROLS - Bullet 2 Button Description

EPH CONTROLS R17V2 1 Zone Timeswitch - b1

  1. Boost Button
    EPH CONTROLS R17V2 1 Zone Timeswitch - b2
  2. Zone Select Button
    EPH CONTROLS R17V2 1 Zone Timeswitch - b3
  3. Master Reset
  4. OK Button
    EPH CONTROLS R17V2 1 Zone Timeswitch - b4
  5. Minus Button
    EPH CONTROLS R17V2 1 Zone Timeswitch - b5
  6. Plus Button
    EPH CONTROLS R17V2 1 Zone Timeswitch - b6
  7. Advance Button
    EPH CONTROLS R17V2 1 Zone Timeswitch - b7
  8. Program Button
    EPH CONTROLS R17V2 1 Zone Timeswitch - b8
  9. Menu Button
    EPH CONTROLS R17V2 1 Zone Timeswitch - b9
EPH CONTROLS - Bullet 2 Wiring Diagram

200-240V~ 50/60Hz EPH CONTROLS R17V2 1 Zone Timeswitch - c1

Terminal Connections

EPH CONTROLS R17V2 1 Zone Timeswitch - c2     Earth
N     Neutral
L      Live
1      COM – Common Connection
2      OFF  – N/C Normally Closed Connection
4      ON   – N/O Normally Open Connection

Switching Options

Mains Switching
– Link L to 1.Low Voltage Switching
– Remove the external controls link from the boiler PCB.
– Connect 1 and 4 to these terminals.
EPH CONTROLS - Bullet 2 Mounting & Installation

EPH CONTROLS R17V2 1 Zone Timeswitch - d1 EPH CONTROLS R17V2 1 Zone Timeswitch - d2 EPH CONTROLS R17V2 1 Zone Timeswitch - d3 EPH CONTROLS R17V2 1 Zone Timeswitch - d4 EPH CONTROLS R17V2 1 Zone Timeswitch - d5 EPH CONTROLS R17V2 1 Zone Timeswitch - d6

Caution!

  • Installation and connection should only be carried out by a qualified person.
  • Only qualified electricians or authorised service staff are permitted to open the timeswitch.
  • If the timeswitch is used in a way not specified by the manufacturer, its safety may be impaired.
  • Prior to setting the timeswitch, it is necessary to complete all required settings described in this section.
  • Before commencing installation, the timeswitch must be first disconnected from the mains.

This timeswitch can be surface mounted or mounted to a recessed conduit box.

1) Remove the timeswitch from its packaging.
2) Choose a mounting location for the timeswitch:
– Mount the timeswitch 1.5 metres above the floor level.
– Prevent direct exposure to sunlight or other heating / cooling sources.
3) Use a philips screwdriver to loosen the screws of the backplate on the bottom of the timeswitch.
The timeswitch is lifted upwards from the bottom and removed from the backplate.
(See Diagram 3 on Page 7)
4) Screw the backplate onto a recessed conduit box or directly to the surface.
5) Wire the backplate as per the wiring diagram on page 6.
6) Sit the timeswitch onto the backplate making sure the timeswitch pins and the backplate contacts are making a sound connection, push the timeswitch flush to the surface and tighten the screws of the backplate from the bottom. (See Diagram 6 on Page 7)

EPH CONTROLS R17-V2 1 Zone Time Switch

1 Zone Timeswitch

Operating Instructions

EPH CONTROLS - Bullet 3 Quick introduction to your R17V2 Timeswitch:

The R17V2 timeswitch has up to three daily heating programs called P1, P2 and P3. See Page 13 for instructions on how to adjust the program settings.
Within these sections you can see what mode the timeswitch is currently in.
When in the AUTO mode, it will show when the timeswitch is next programmed to be switched ON or OFF.
For ‘Mode Selection’ please see page 11 for further explanation.
When the timeswitch is ON, you will see the red LED light up. This indicates that power is being sent from the timeswitch.

EPH CONTROLS - Bullet 3 Mode Selection EPH CONTROLS R17V2 1 Zone Timeswitch - a1 AUTO

There are four modes available for selection.
AUTO        The timeswitch operates up to three ‘ON/OFF’ periods per day (P1,P2,P3).
ALL DAY   The timeswitch operates one ‘ON/OFF’ period per day. This operates from the first ‘ON’ time to the third ‘OFF’ time.
ON             The timeswitch is permanently ON.
OFF            The timeswitch is permanently OFF.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b3 to change between AUTO, ALL DAY, ON & OFF.
The current mode will be shown on the screen.
The EPH CONTROLS R17V2 1 Zone Timeswitch - b3 is found under the front cover.

EPH CONTROLS - Bullet 3 Programming Modes

This timeswitch has the following programming modes.
5/2 Day mode   Programming Monday to Friday as one block and Saturday and Sunday as a 2nd block.
7 Day mode      Programming all 7 days individually.
24 Hour mode  Programming all 7 days as one block.

EPH CONTROLS - Bullet 3 Factory Program Settings EPH CONTROLS R17V2 1 Zone Timeswitch - a1 5/2d

5/2 Day

EPH CONTROLS R17V2 1 Zone Timeswitch - a1 P1 ON P1 OFF P2 ON P2 OFF P3 ON

P3 OFF

Mon-Fri

06:30 08:30 12:00 12:00 16:30 22:30
Sat-Sun 07:30 10:00 12:00 12:00 17:00

23:00

7 Day

P1 ON

P1 OFF P2 ON P2 OFF P3 ON P3 OFF
All 7 days 06:30 08:30 12:00 12:00 16:30

22:30

24 Hour

P1 ON

P1 OFF P2 ON P2 OFF P3 ON P3 OFF
Everyday 06:30 08:30 12:00 12:00 16:30

22:30

EPH CONTROLS - Bullet 3 Adjust the Program Setting in 5/2 Day Mode

Press EPH CONTROLS R17V2 1 Zone Timeswitch - b8.
Programming for Monday to Friday is now selected.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the P1 ON time.         Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the P1 OFF time.        Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Repeat this process to adjust P2 and P3 times.
Programming for Saturday to Sunday is now selected.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the P1 ON time.          Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the P1 OFF time.         Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Repeat this process to adjust P2 and P3 times.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9 to return to normal operation.
While in programming mode, pressing EPH CONTROLS R17V2 1 Zone Timeswitch - b3 will jump to the next day (block of days) without changing the program.

Note:

  1. To change from 5/2d to 7D or 24H programming, refer to page 16, Menu P01. 
  2. If you don’t wish to use one or more of the daily programs then simply set the start time and end time to be identical. For example, if P2 is set to start at 12:00 and end at 12:00 the timeswitch will simply ignore this program and proceed to the next switching time.
EPH CONTROLS - Bullet 3 Reviewing the Program Settings

Press EPH CONTROLS R17V2 1 Zone Timeswitch - b8.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4 to scroll through the periods for the individual day (block of days).
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b3 to jump to the next day (block of days).
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9 to return to normal operation.

EPH CONTROLS - Bullet 3 Boost Function

The timeswitch can be boosted for 30 minutes, 1, 2 or 3 hours while it is in the AUTO, ALL DAY & OFF mode.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b2 1, 2, 3 or 4 times, to apply the desired BOOST period.
When a EPH CONTROLS R17V2 1 Zone Timeswitch - b2 is pressed there is a 5 second delay before activation where ‘BOOST’ will flash on the screen, this gives the user the time to select the desired BOOST period.
To cancel a BOOST, press EPH CONTROLS R17V2 1 Zone Timeswitch - b2 again.
When a BOOST period has ended or has been cancelled, the timeswitch will return to the mode that was previously active prior to the BOOST.

Note: A BOOST cannot be applied while in the ON or Holiday Mode.

EPH CONTROLS - Bullet 3 Advance Function

When the timeswitch is in the AUTO or ALLDAY mode, the Advance function allows the user to bring it forward to the next switching time.
If the timeswitch is currently timed to be OFF and EPH CONTROLS R17V2 1 Zone Timeswitch - b7 is pressed, it will be switched ON until the end of the next switching time. If the timeswitch is currently timed to be ON and EPH CONTROLS R17V2 1 Zone Timeswitch - b7 is pressed, it will be switched OFF until the start of the next switching time.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b7.
The timeswitch will display ‘ADVANCE ON’ or ‘ADVANCE OFF’ until the end of the next switching time.
To cancel an ADVANCE, press EPH CONTROLS R17V2 1 Zone Timeswitch - b7 again.
When an ADVANCE period has ended or has been cancelled, the timeswitch will return to the mode that was previously active prior to the ADVANCE.

EPH CONTROLS - Bullet 3 Menu

This menu allows the user to adjust additional functions.
To access the menu, press EPH CONTROLS R17V2 1 Zone Timeswitch - b9.

EPH CONTROLS - Bullet 1 P01 Setting the Date, Time and the Programming Mode EPH CONTROLS R17V2 1 Zone Timeswitch - a1 DST ON

Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9, ‘P01 tInE’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4, the year will begin to flash.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the year.                            Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the month.                        Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the day.                             Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the hour.                           Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the minute.                        Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust from 5/2d to 7d or 24h mode.   Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to turn DST (Day Light Saving time) On or Off.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9 and the timeswitch will return to normal operation.

Note:
Please see page 12 for descriptions of Programming Modes.

EPH CONTROLS - Bullet 1 P02 Holiday Mode

This menu allows the user to switch off their heating system by defining a start and end date.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9, ‘P01’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 until ‘P02 HOL’ will appears on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4, ‘HOLIDAY FROM’, the date and time will appear on the screen. The year will begin to flash.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the year.                           Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the month.                       Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the day.                             Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the hour.                           Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
HOLIDAY TO’ and the date and time will appear on the screen. The year will begin to flash.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the year.                           Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the month.                       Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the day.                             Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to adjust the hour.                           Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
The timeswitch will now be switched off during this selected period.
To cancel the HOLIDAY, press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
The timeswitch will return to the normal operation when a holiday has finished or been cancelled.

EPH CONTROLS - Bullet 1 P03 Frost Protection EPH CONTROLS R17V2 1 Zone Timeswitch - a1 OFF

This menu allows the user to activate the frost protection between a range of 5°C and 20°C.
Frost protection is default set to OFF.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9, ‘P01’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 until ‘P03 FrOST’ appears on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4, ‘OFF’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 to select ‘ON’.                                              Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
5˚C’ will flash on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to select your desired frost protection temperature.  Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9 and the timeswitch will return to normal operation.

The Frost symbol EPH CONTROLS R17V2 1 Zone Timeswitch - e2 will display on the screen if the user activates it in the menu.

If the ambient room temperature drops below the desired frost protection temperature, the timeswitch will activate and the frost symbol will flash until the frost protection temperature has been achieved.

EPH CONTROLS - Bullet 1 P04 Zone Title

This menu allows the user to select different titles for the timeswitch.
The options are:

DEFAULT OPTION

RENAME OPTION 1 RENAME OPTION 2
ZONE HEATING

HOT WATER

Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9, ‘P01’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 until ‘P04’ appears on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4, ‘ZONE’ will flash on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 to change from ‘ZONE’ to ‘HEATING’ or ‘HOT WATER’.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9 and the timeswitch will return to normal operation.

EPH CONTROLS - Bullet 1 P05 PIN

This menu allows the user to put a PIN lock on the timeswitch.
The PIN lock will reduce the functionality of the timeswitch.

Set up the PIN

Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9, ‘P01’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 until ‘P05 PIn’ appears on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4, ‘OFF’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 to change from OFF to ON. Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4. ‘0000’ will flash on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to set the value from 0 to 9 for the first digit. Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4 to move to the next PIN digit.
When the last digit of the PIN is set, press EPH CONTROLS R17V2 1 Zone Timeswitch - b4. Verify is displayed with ‘0000’.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to set the value from 0 to 9 for the first digit. Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4 to move to the next PIN digit.
When the last digit of the PIN is set, press EPH CONTROLS R17V2 1 Zone Timeswitch - b4. The PIN is now verified, and the PIN lock is activated.
If the verification PIN is entered incorrectly the user is brought back to the menu.
When the PIN lock is active the Lock symbol EPH CONTROLS R17V2 1 Zone Timeswitch - e1 will flash every second on the screen.
When the timeswitch is PIN locked, pressing the menu will take the user to the PIN unlock screen.

Note:
When the PIN lock is enabled, BOOST periods are reduced to 30 minute and 1 hour periods.
When the PIN lock is enabled, Mode Selections are reduced to Auto and OFF.

To Unlock the PIN

Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9, ‘UNLOCK’ will appear on the screen. ‘0000’ will flash on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to set the value from 0 to 9 for the first digit.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4 to move to the next PIN digit.
When the last digit of the PIN is set.                         Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
The PIN is now unlocked.
If a PIN has been unlocked on the timeswitch, it will automatically reactivate if there is no button pressed for 2 minutes.

To Deactivate the PIN

When the PIN is unlocked (see above instructions)
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9, ‘P01’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 until ‘P05 PIn’ appears on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4, ‘ON’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 or EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to select ‘OFF’.                             Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
0000’ will flash on the screen. Enter the PIN.           Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4.
The PIN is now disabled.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9 to return to normal operation or it will automatically exit after 20 seconds.

EPH CONTROLS - Bullet 3 Copy Function

Copy function can only be used when the 7d mode is selected. (See page 16 to select 7d mode)
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b8 to program the ON and OFF periods for the day for the week you want to copy.
Do not press OK on the P3 OFF time, leave this period flashing.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b7, ‘COPY’ will appear on the screen, with the next day of the week flashing.
To add the desired schedule to this day press EPH CONTROLS R17V2 1 Zone Timeswitch - b6.
To skip this day press EPH CONTROLS R17V2 1 Zone Timeswitch - b5.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4 when the schedule has been applied to the desired days.
Ensure the timeswitch is in the ‘Auto’ mode for this schedule to operate accordingly.

EPH CONTROLS - Bullet 3 Backlight Mode Selection EPH CONTROLS R17V2 1 Zone Timeswitch - a1 ON

There are 3 backlight settings available for selection:
AUTO    Backlight stays on for 10 seconds when any button is pressed.
ON         Backlight is permanently On.
OFF        Backlight is permanently Off.

To adjust the backlight press and hold EPH CONTROLS R17V2 1 Zone Timeswitch - b4 for 10 seconds.
Auto’ appears on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 or EPH CONTROLS R17V2 1 Zone Timeswitch - b5 to change the mode between Auto, On and Off.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4 to confirm selection and to return to normal operation.

EPH CONTROLS - Bullet 3 Locking the Keypad

To lock the timeswitch, press and hold EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 together for 10 seconds.
EPH CONTROLS R17V2 1 Zone Timeswitch - e1 will appear on the screen. The buttons are now disabled.
To unlock the timeswitch, press and hold EPH CONTROLS R17V2 1 Zone Timeswitch - b6 and EPH CONTROLS R17V2 1 Zone Timeswitch - b5 for 10 seconds.
EPH CONTROLS R17V2 1 Zone Timeswitch - e1 will disappear from the screen. The buttons are now enabled.

EPH CONTROLS - Bullet 3 Resetting the Timeswitch

To reset the timeswitch to factory settings:
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b9.
P01’ will appear on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6 until ‘P06 rESEt’ appears on the screen.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4 to select.
nO’ will begin to flash.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b6, to change from ‘nO’ to ‘YES’.
Press EPH CONTROLS R17V2 1 Zone Timeswitch - b4 to confirm.
The timeswitch will restart and revert to its factory defined settings.
The time and date will not be reset.

EPH CONTROLS - Bullet 3 Master Reset

To master reset the timeswitch to factory settings, locate the master reset button on the right-hand side underneath the timeswitch. (see page 5)
Press the Master Reset button and release it.
The screen will go blank and reboot.
The timeswitch will restart and revert to its factory defined settings.

EPH CONTROLS - Bullet 3 Service Interval EPH CONTROLS R17V2 1 Zone Timeswitch - a1 OFF

The service interval gives the installer the ability to put an annual countdown timer on the timeswitch. When the Service Interval is activated ‘SErv’ will appear on the screen which will alert the user that their annual boiler service is due.

For details on how to enable or disable the Service Interval, please contact customer service.

EPH Controls Ltd.

EPH Controls IE
technical@ephcontrols.com
www.ephcontrols.com/contact-us
T +353 21 471 8440

EPH CONTROLS R17V2 1 Zone Timeswitch - QR Code 1

EPH Controls UK
technical@ephcontrols.co.uk
www.ephcontrols.co.uk/contact-us
T +44 1933 322 072

EPH CONTROLS R17V2 1 Zone Timeswitch - QR Code 2

EPH CONTROLS logo2

©2024 EPH Controls Ltd.
2024-01-04_R17-V2_DS_PK